| Plan Review Stops For Permit 01071546 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-08-16 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-08 |
Time |
22:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-08 |
Time |
22:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-02 |
Time |
19:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-02 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | 1) EXIT SIGN LOCATED IN BATHROOM NOT | | | REQUIRED. | | | 2) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR THE HOOD, DUCT, AND SUPPRESSION | | | SYSTEMS. | | | 3) WALL DETAIL ON PAGE A-1 INDICATES | | | 5X8 DRYWALL. IT SHOULD READ 5X8 TYPE X | | | DRYWALL. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-12 |
Time |
07:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-10-12 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2001-10-12 00:00:00 | *******************PROVISO************** | | | | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPRESSION AND WALK-IN COOLERS. | | | PLEASE PROVIDE PLANS WITH PERMIT | | | APPLICATION. | | | | | | TERMINATION FOR HOOD EXHAUST SHALL | | | COMPLY WITH 1997 SMC 506.1. | | | | | | 1.SHALL BE LOCATED 10' FROM ANY | | | ADJACENT BUILDING, PARKING AREA, | | | ADJACENT PROPERTY LINE, AS WELL AS | | | ANY WINDOW DOOR OR AIR INTAKE. | | | | | | 2.EVERY EXHAUST OUTLET WHICH IS | | | LOCATED ABOVE THE ROOF SHALL | | | TERMINATE AT LEAST 40" ABOVE THE | | | ROOF SURFACE. | | | | | | THE DISTANCE FROM THE FLOOR TO THE | | | BOTTOM EDGE OF THE HOOD IS NOT LEGIBLE | | | ON PLAN.AS PER 1997 SMC 504.2 #2 THIS | | | DISTANCE SHALL BE A MAXIMUM OF 7'. | | | | | | NOTE:REFERENCE THE CONDENSER UNIT | | | STANDS.COMMENTS FROM 8/20/01 | | | WERE NOT ADDRESSED IN THE | | | RESUBMITTAL.A MINIMUM OF 18" | | | IS REQUIRED BETWEEN THE ROOF | | | SURFACE TO THE BOTTOM OF THE | | | SUPPORT RAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-20 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-20 |
Time |
08:24 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-08-20 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2001-08-20 00:00:00 | DENIED: | | | 1. HOOD EXHAUST TERMINATION DOES NOT | | | COMPLY WITH 1997 SMC 506.1 PROVIDE | | | INFORMATION SHOWING MINIMUM 10' FROM | | | ANY ADJACENT PROPERTY LINE PARKING | | | AREA, AIR INTAKE, WINDOW, OR DOOR. | | | 2. NO INFORMATION PROVIDED FORAIR | | | CONDITIONING SYSTEM. | | | 3. NOTE SEPARATE PERMITS WILL BE | | | REQUIRED FOR HOOD, SUPPRESSION SYSTEM | | | AND WALK IN COOLERS. PROVIDE PLANS AT | | | TIME OF PERRMIT APPLICATION FOR THIS | | | WORK. | | | 4. MINIMUM CLEARANCE FROM BOTTOM OF | | | SUPPORT BEAM OF STAND TO FINISHED ROOF | | | SURFACE TO BE 18". |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-11 |
Time |
09:30 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-11 00:00:00 | REVISION, RE-LOCATE GREASE TRAP. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-11 |
Time |
17:50 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-11 |
Time |
17:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-04 |
Time |
13:25 |
Rev Time |
1.55 |
| Received By |
kstevens |
Date |
2001-10-04 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2001-10-04 00:00:00 | DENIED | | | | | | GREASE TRAP TO BE SIZED BY WPB UTILITIES | | | PLEASE CALL RODNEY COMPO (561) 837-4074. | | | | | | A VAULT IS REQUIRED WITH A TRAFFIC LID. | | | ALARMS REQUIRED- ONE FOR TANK AND ONE | | | FOR THE SUMP PUMP. | | | | | | GREASE TRAP WILL HAVE TO HAVE 3" INTAKE | | | AND OUTLET. | | | | | | MOP SINK - 3 COMP SINK - FLOOR DRAINS TO | | | GREASE, ALL OTHER TO SANITARY. | | | | | | PLEASE PROVIDE LETTER FROM R COMPO AND | | | DETAILS OF GREASE TRAP WITH ALARMS, SUMP | | | ECT. INDICATED. | | | | | | PLEASE PROVIDE NEW GREASE AND SANITARY | | | RISER DIAGRAMS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-08-15 |
Time |
18:10 |
Rev Time |
2.00 |
| Received By |
jleech |
Date |
2001-08-15 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2001-08-15 00:00:00 | DENIED; | | | 1.GREASE TRAP TO BE SIZED BY WEST PALM | | | BEACH UTILITYS DEPARTMENT. CONTACT | | | RODNEY COMPO AT 837-4074. | | | 2.SHOW COMPLIANCE WITH 94 SPC TABLE 407 | | | MINIMUM PLUMBING FACILITIES. SEE SEC. | | | 407.1.3 FOR DEDUCTABLE AREA. | | | 3.PAGE P-1 WATER RISER DIAGRAM, SIZE | | | PIPES. | | | 4.SHOW ON WATER RISER WHERE WATER HAMMER | | | ARRESTERSARE TO BE INSTALLED.SPECIFY | | | TYPE AND SIZE. TO BE INSTALLED PER | | | MANUFACTORS RECOMMENDATIONS AND SPC | | | SEC. 607.8.2 AND 607.8.3. | | | 5.NOTE 13 WASTE PIPING LESS THAN 3" TO | | | HAVE A PITCH OF 1/4" PER FOOT PER. SEC | | | 705.2 | | | 6.NOTE 14 DIELECTRIC COUPLINGS ARE NOT | | | PERMITED IN CITY WATER SYSTEM. | | | 7.NOTE 8 GALVANIZED WATER PIPE IS NOT | | | PERMITED IN CITY WATER SYSTEM. | | | 8.THREE COMPARTMENT SINK SHALL DISCHARGE | | | INDIRECTLY INTO A FLOOR SINK. SEC. | | | 804.1. | | | 9.( SANITARY RISER DIAGRAM) | | | A.SHOW 3" VENT TO OUT SIDE. | | | B.2 FLOOR SINKS ARE MISSING FROM | | | DIAGRAM. | | | C.WHAT DO DOTTED LINES MEAN? (STEAM | | | TABLE TO FLOOR DRAIN. FLOOR SINK | | | TO FLOOR DRAIN) | | | 10.GAS RISER DIAGRAM. NOT ENOUGH INFOR- | | | MATION. AUTOMATIC SHUTOFF VALVE TO | | | BE INSTALLED WITH HOOD SYSTEM. SHOW | | | ON DRAWINGS AND ON RISER DIAGRAM. SEE | | | INFORMATION SHEET. PLEASE COMPLY WITH | | | NUMBER HIGHLIGHTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|