| Plan Review Stops For Permit 01071485 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-06-28 |
Time |
14:31 |
Rev Time |
2.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-06-28 00:00:00 | APPROVED GRAND STAIR RAIL REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-11-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
10:13 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-11-20 00:00:00 | APPROVAL FOR SUSPENDED CEILING LM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:14 |
Rev Time |
2.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | | | | SUSPENDED CEILING SUBMITTAL | | | | | | IS DENIED FOR THE FOLLOWING REASONS: | | | | | | 1] | | | ALL CALCULATIONS AND ACCOMPANYING | | | DRAWINGS SHALL BE SIGNED AND SEALED BY | | | P.E. WARDEN. | | | | | | 2] | | | SUBMIT ANCHORING DETAILS FOR WIRE AT | | | EXSISTING SUPPORTING STRUCTURE. SUBMIT | | | SUPPORTING DOCUMENTATION TO CLARIFY #8 | | | WIRES CAPACITY,NOTE ON CALCULATION | | | SHEET 'PROBABLY ADEQUATE' IS NOT | | | SUFFICIENT. | | | | | | 3] | | | PROVIDE THICKNESS AND SPEC. ON WELD FOR | | | ALUMINUM ANGLE. | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 805-6710 | | 2003-01-09 00:00:00 | PROCESS SHOP DRAWINGS APPROVED ON 12/26 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-12-11 |
Time |
18:42 |
Rev Time |
20.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | | | | SHOP DRAWING REVIEWS | | | -------------------- | | | | | | FAILED SUBMITTALS: | | | | | | DUCTWORK-SHEARWALL PENETRATIONS | | | SLIDING METAL FIRE DOORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-06 |
Time |
16:32 |
Rev Time |
20.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-29 00:00:00 | | | | BUILDING COMMENTS | | | ----------------- | | | :PROVISO: | | | 1] | | | SHEET A1-4.1 AND A1-4.2, NUMBERS ON | | | EGGRESS ARROWS FOR OCCUPANT EXITING | | | COUNT ARE NOT CORRECT. | | | 2] | | | CONTRACTOR SHALL SUBMIT FOR SEPERATE | | | PERMITS FOR ALL EXTERIOR GLAZING, DOORS | | | AND ROOF COVER. | | | 3] | | | ARCHITECT HAS BEEN CONTACTED TO REVIEW | | | REMAINING ACCESSIBITY ISSUES. | | | | | | | | | | | | PLAN REVIEWER: | | | LUIS MARTINEZ | | | 561-659-8096 | | | #8456 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-09-12 |
Time |
16:10 |
Rev Time |
50.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-12 00:00:00 | | | | BUILDING COMMENTS | | | ----------------- | | | | | | 1] | | | PLEASE ADDRESS COMMENTS #S,6,7 AND 8 | | | FROM THE FIRE REVIEW LIST. | | | 2] | | | PROVIDE SIGNED AND SEALED FIRE | | | SPRINKLER LAYOUT BY THE DESIGN | | | PROFESSIONAL. | | | 3] | | | WILL GUTTER SYSTEM BE PROVIDED FROM | | | PITCHED ROOF PORTION OF THE DRIVE-UP | | | ENTRY CANOPY. | | | 4] | | | SUBMIT SPECIFICATIONS FOR THE 2-HR | | | RATED FIRE SHUTTER AT BOARD ROOM. | | | 5] | | | HAVE DESIGN ENGINEER LIST ON HIS | | | DRAWINGS ALL POSITIVE AND NEGATIVE | | | PRESSURES FOR ALL EXTERIOR OPENINGS. | | | SUBMIT APPROVED TEST REPORTS FOR ALL | | | EXTERIOR GLAZING AND DOORS. SHALL | | | COMPLY WITH BOTH WIND LOADING AND | | | IMPACT RESISTANCE. | | | 6] | | | PROVIDE 2HR RATED WALL SEPERATING THE | | | CHILLER PLANT FROM THE UNDERSIDE OF THE | | | EXTERIOR STAIRCASE. SH. A1-5.1. | | | 7] | | | DOOR SCHEDULES, PROVIDE SPECIFICATIONS | | | ON THE HARDWARE GROUPS. SH8-1.1 AND 1.2 | | | 8] | | | PLEASE SHOW COMPLIANCE WITH SBC | | | 705.2.2, SHAFT ENCLOSURES FOR | | | ESCALATORS. | | | 9] | | | ATRIUMS, SBC 414.6 SMOKE DETECTORS AND | | | 414.10 INTERIOR FINISH, PLEASE IDENTIFY | | | COMPLIANCE. | | | 10] | | | SBC 1004.3.5, IDENTIFY AREAS OF REFUGE. | | | 11] | | | SBC 1007.3, ALL STAIRWAYS SHALL COMPLY | | | WITH THE RISE AND RUN RATIO. | | | 12] | | | PLEASE COMPLETE THE SUBMITTED FLA. | | | ENERGY FORMS. OWNER SHALL SIGN,AND ALL | | | 9 SETS SUBMITTED ARE FOR THE SAME AREA | | | OF THE BUILDING??? | | | 13] | | | EXIT AT LOADING DOCK AREA IS TO BE | | | CLEARLY MARKED WITH SIGNS AND PATH OF | | | TRAVELIDENTIFIED. | | | 14] | | | SHEET A1-5.2, EXPLAIN 2HR RATING BEHIND | | | INTERIOR OFFICES AT KITCHEN AREA. | | | | | | PLEASE SEE ADDITIONAL COMMENTS PROVIDED | | | FOR ACCESSIBILITY COMPLIANCE. | | | SEPERATE PACKAGE SHEETS,1 THRU 9. | | | | | | | | | PLAN REVIEWER: | | | LUIS MARTINEZ | | | 561-659-8096 | | | #8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
30 |
Status |
P |
Date |
2004-04-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-04-26 |
Time |
13:42 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2004-04-26 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
29 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-07 |
Time |
16:51 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-01-13 |
Time |
12:04 |
Sent To |
FIRE |
|
| Notes |
| 2004-01-13 00:00:00 | *** REV FOR EMT LTS . TO BE SENT TO | | | FIRE DUE TO EM LTS REV. | | | E1.103, 1.104 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
28 |
Status |
P |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
09:12 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-12-05 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
27 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-26 |
Time |
09:02 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-11-03 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | REV FOR HIGH BAY TYPE OF LT FIXTURES AND | | | LOAD.. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
26 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-03 |
Time |
14:25 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-11-03 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | **** UNSAT ********** | | | | | | RFI'S | | | 1085 | | | 1075 | | | 1070 | | | 1068 | | | 1015 | | | 1022 | | | 1069 | | | 1155 | | | | | | PLEASE REMOVE ALL SHEETS THAT ARE NOT | | | SIGNED DATED AND SEALED. THESE CAN NOT | | | BE SUBMITTED FOR RECORD UNLESS. S/D/S | | | BY ENGINEER OF RECORD. IF THESE REV'S | | | HAVE ALREADY COME IN, PLEASE DO NOT | | | SUBMIT. | | | PLEASE FILL OUT COVER SHEET AND APPLY | | | HOW MANY SHEETS ARE BEING REVISED. | | | THESE ARE REV'S AND NOT SUBMITTALS. | | | PLEASE NOTE; IF PANEL SCHEDULES THAT | | | ARE ON 8 1/2 X 11'S ARE ON ONE SHEET | | | ON PLANS. IT WOULD BE COST EFFECTIVE' | | | IF LESS REVISED SHEETS WERE SUBMITTED. | | | JUST AN FYI. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
25 |
Status |
N |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-03 |
Time |
13:54 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-11-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | GENERATOR /WALL LOUVER REV TO INCOMING | | | TO PUT ON COM BOARD. NEEDS FIRE AND BLDG | | | . |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
24 |
Status |
N |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-03 |
Time |
13:53 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-11-03 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | N/A BACK TO H MOSER. (1 SET) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
23 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-11-03 |
Time |
13:47 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-11-03 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | E-2.101 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
22 |
Status |
P |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-10-29 |
Time |
17:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-05-12 |
Time |
07:36 |
Sent To |
M |
|
| Notes |
| 2003-05-12 00:00:00 | RFI SUBMITTALS OK, NO PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
21 |
Status |
P |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-09 |
Time |
15:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-09 |
Time |
15:15 |
Sent To |
M |
|
| Notes |
| 2003-05-09 00:00:00 | THIS REVIEW WAS SUBMITTALS CONTAINING | | | RFI'S ONLY,NO PLANS INVOLVED./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
20 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-30 |
Time |
14:06 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2003-04-30 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | ***************** UNSAT ************* | | | | | | PLEASE SUBMIT THREE COMPLETE SETS FOR | | | REVIEW. | | | PLEASE INSERT ALL DATED SHEETS FROM | | | REV DATED 3/5/03 INTO SHEETS DATED | | | 4/3/03 | | | | | | PLEASE NOTE, ELECTRICAL REVISIONS, OK | | | TO COME BACK IN W/OUT FEE. | | | IF THERE ARE ANY QUESTIONS,PLEASE SEE | | | DV PALMER | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
19 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-15 |
Time |
07:47 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-04-15 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | *********** HOLD WAITING********** | | | | | | ELECTRICAL REVISIONS BROUGHT IN ON 4/11 | | | WERE NOT COMPLETE WITH REVS FROM LAST | | | SUBMITTAL FROM 3/10/03. | | | PLANS SHOULD BE MADE INTO COMPLETE SETS | | | FOR STAMPING AND REVIEW. | | | REVISIONS 67/67A&B DATED FROM 9/20/02 | | | 12/02, 1/03 ETC | | | | | | CALLED BOB RILING AND SPOKE W/ HIM | | | ABOUT GETTING SETS BACK AND PUT | | | TOGETHER. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | PLANS ON HOLD. DO NOT RELEASE | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
18 |
Status |
P |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
14:54 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-04-10 |
Time |
17:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
17 |
Status |
I |
Date |
2003-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-20 |
Time |
16:43 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2003-03-20 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2003-03-21 00:00:00 | PLANS ARE UP FRONT UNDER "T" WAITING | | | FOR OTHER SHEETS. SEE DV PALMER | | | OTHER SHEETS OK TO COME IN W/OUT FEE. | | | | | | IF THERE ARE ANY QUESTIONS, | | | SEE DV PALMER. | | 2003-03-20 00:00:00 | PLANS ARE ON HOLD WAITING FOR ADDITIONAL | | | SHEETS FROMISSUE #67 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
16 |
Status |
F |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-12 |
Time |
16:34 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-02-19 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | ****************** UNSAT ************** | | | | | | | | | 1)NOTE: PLEASE SEE NOTE FROM REVIEW #13 | | | ATTACHED. PLEASE ADDRESS THOSE COMMENTS | | | AND SUBMIT ALL REVISED PLANS AND CHANGES | | | TO DATE. | | | | | | 2)NOTE:PLEASE NOTE, AFTER A FIELD | | | INSPECTION WITH ELECTRICAL INPECTOR, | | | IT HAS COME TO OUR ATTENTION HE IS DOING | | | INSPECTION OFF A SET OF PLANS FROM 2001? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
15 |
Status |
P |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-14 |
Time |
15:39 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-14 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2003-02-14 00:00:00 | LT SPECS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
P |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-11 |
Time |
07:29 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-12-11 |
Time |
07:29 |
Sent To |
M |
|
| Notes |
| 2002-12-11 00:00:00 | RFI FOR CHANGE OF SYMBOL FOR STROBE. | | | | | | REVISION FOR COMMENST FROM 13TH REV NOT | | | ADDRESSED AT THIS TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
F |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-25 |
Time |
07:10 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2002-11-25 |
Time |
07:10 |
Sent To |
FIRE |
|
| Notes |
| 2002-11-25 00:00:00 | REVISIONS, LTG CONTROLS#4 &5 | | | | | | ********** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE, LOADS SHOWN FOR | | | REVISED PANELS/RISERS NEED TO CORRELATE. | | | PLEASE NOTE WHEN LOAD CHANGES FOR "HP" | | | PANELS, PLEASE ADJUST FOR DPH`S THAT | | | FEED THOSE PANELS. | | | PLEASE ALSO NOTE, LOADS ON MSB-1 NEED TO | | | CORRELATE WITH DPH`S LOADS SHOWN. | | | PLEASE NOTE SOME DO AND SOME DON'T. | | | | | | PLEASE NOTE,LOADS ON MSB-2 AND | | | EMDP-1 NEED TO CORRELATE ALSO WITH | | | OTHER PANELS AND LOADS THEY SHOW. | | | | | | PLEASE SUBMIT THE ABOVE INFROAMTION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
N |
Date |
2002-11-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-19 |
Time |
15:31 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-19 |
Time |
15:31 |
Sent To |
M |
|
| Notes |
| 2002-11-19 00:00:00 | SUBMITTALS FOR BLDG ENERGY MANG CONTROLS | | | NOT FOR ELECTRICAL REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-21 |
Time |
07:46 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-10-21 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | *************** UNSAT ****************** | | | | | | | | | 1)NOTE: PLEASE NOTE LIGHTNING PROTECTION | | | SYSTEM IS TO BE PERMITTED SEPARATELY. | | | PLEASE SUBMIT PLANS ALONG WITH SUBMITTAL | | | -S. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND PERMIT APPLICATION. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-21 |
Time |
07:46 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2002-10-21 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | SUBMITTALS FOR MATERIALS ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2002-08-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-13 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-08-01 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2002-05-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-23 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-23 |
Time |
06:26 |
Sent To |
|
|
| Notes |
| 2002-05-23 00:00:00 | ************** /NOTE ************ | | | | | | | | | 1)NOTE: PLEASE NOTE THIS IS A REVISION | | | FOR ELECTRICAL AND OWES FEE. | | | | | | 2)NOTE: PLEASE ALSO NOTE THAT THIS IS | | | A SECOND REQUEST THAT THE VALUE OF JOB | | | BE INCREASED TO CORRELATE WITH THE NEW | | | CONTRACT VALUE. THIS WAS REQ`UESTED AT | | | THE END OF MARCH AND TO DATE NOTHING | | | HAS BEEN DONE. | | | | | | PLEASE SUBMIT THE ABOVE AS A REVISION | | | AND ADDRESS NOTE #2. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | PLEASE CALL BILL STAPLES ABOUT VALUE | | | OF WORK IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | | | | BILL STAPLES | | | ASST BUILDING OFFICIAL | | | 561-659-8096 EXT 8315 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2002-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-01 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-01 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2002-03-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-19 |
Time |
05:58 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2002-03-18 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2002-03-19 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT THE FOLLOWING | | | PANEL SCHEDULES NEED TO BE SUBMITTED FOR | | | REVIEW.EHP-6/EHP-7/ELP6A/ELP7A. | | | | | | 2)NOTE: PLEASE NOTE THAT THE FOLLOWING | | | ITEMS ON ONE-LINE DIAGRAM NEED TO MATCH/ | | | CORRELATE WITH ALL PANEL SCHEDULES. | | | NEC-215-5 | | | DPH2, 4ITEMS. | | | DPH1, MAIN | | | MSB1, DISC #3 | | | DPH4, MAIN | | | DPL4, MAIN AND 4TH BRKR | | | DPL3, 4TH BRKR | | | HP3,2 ITEMS | | | MSB-2, PANEL S2?, EMDP-1 | | | HP8, 2 BRKRS | | | LP8, 3 BRKRS | | | EMDP1, EMCC1,ELEV, 1&5,EHP6 | | | MSB-3, 6 MAIN BRKRS | | | MCC2, MAIN AND OTHER MAIN BRKRS | | | MCC1, 4 BRKRS, AND AHU 15/16 | | | MCC3, 4BRKRS. | | | | | | PLEASE NOTE THAT MOST OF THE ABOVE HAVE | | | SOME DIFFERENCES ON PANEL SCHEDULES. | | | PLEASE ALSO NOTE THAT THERE MAY BE OTHER | | | -S THAT WERE NOT LOCATED, PLEASE GO | | | OVER PLANS. | | | | | | 3)NOTE: PLEASE PROVIDE A LOAD SUMMARY | | | FOR GENERATOR, SINCE GEN SIZE HAS BEEN | | | DECREASED. | | | | | | 4)NOTE: PLEASE HAVE PERMIT VALUATION | | | INCREASED DUE TO CONTRACT INCREASES. | | | PLEASE VERIFY AMOUNTS. CITY-WIDE ADMIN | | | CODE.104.7.5 (1997) EDITION. | | | | | | 5)NOTE: PLEASE SUBMIT REVISIONS FROM | | | PREVIOUS REVIEW THAT WERE NOT SUBMITTED | | | BACK FOR STAMPING. THE FLOOR LAYOUTS | | | DID NOT HAVE ANY COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE NAY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2002-02-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-22 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-22 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2002-02-22 00:00:00 | ******************* UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THERE ARE ANY PANELS | | | THAT THE LOADS WERE NOT REVISED WHEN | | | LOADS WERE ADDED. | | | PLEASE SEE; | | | "EHP1" | | | "EHP2" | | | "EHP3" | | | "LP-5 | | | "LP-7" | | | "LP-8" | | | "EHP6" | | | "EMCC-1" | | | | | | PLEASE NOTE THAT "MCC4" ALSO DOES NOT | | | HAVE ALL LOADS REVISED. | | | PLEASE NOTE THAT LOAD FOR "MSB3" WAS | | | NOT REVISED. | | | PLEASE NOTE LOAD FOR "MCC-1" ALSO NEEDS | | | TO BE REVISED. | | | PLEASE NOTE THAT PANEL SCHEDULE NEED TO | | | BE REVISED. PLEASE NOTE LOAD SHOWN | | | ON MSB-3 ALREADY IS AT 3417AMPS. | | | | | | 2)NOTE: PLEASE NOTE THAT ONE LINE SHOWS | | | AHU#15 AT 60HP AND "MCC1" SHOWS AT 50HP | | | AND LOAD FOR HP. PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE E6.109 LP-8 25,27,29 | | | SHOWS 60A AND E2.202 SHOWS 30A. PLEASE | | | CORRELATE. | | | | | | 4)NOTE: PLEAS SUBMIT LINE DIAGRAM THAT | | | WOULD INCLUDE LP-8. | | | | | | | | | PLEASE REVISE AND SUBMIT ALL OF THE | | | ABOVE INFORMATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-20 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-20 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-15 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-15 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2001-11-15 00:00:00 | ********** PASSED PENDING ************* | | | MINOR CHANGES TO BE NOTED ON PLANS FOR | | | FIRE PUMP OCP,ATS, AND DISCONNECT. | | | | | | TO BE COMPLETED1PM 11/15/01. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-12 |
Time |
05:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-12 |
Time |
05:28 |
Sent To |
|
|
| Notes |
| 2001-10-12 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT COLOR CODING | | | OF FEEDERS ON E5.101 SHOWS CONDUCTORS | | | FOR 277/480 AS BLK,RED,BLUE. PLEASE | | | NOTE THAT PER LOCAL AMENDMENTS THE COLOR | | | -S FOR 277/480 IS BR/PURPLE/YELLOW. | | | PLEASE ASLO PLACE THIS NOTE ON EACH OF | | | THE ONE-LINE DIAGRAMS. ART:215 | | | NOTE FROM NOTE #5 ON FIRST REVIEW. | | | | | | 2)NOTE: PLEASE NOTE, OCP IS NOW SHOWN | | | ON LINE DIAGRAM FOR FIRE PUMP AS 800A`S | | | ON FPL LINE. PLEASE NOTE THAT OCP THAT | | | IS SHOWN COMING FROM GENERATOR IS SHOWN | | | AT 200A`S.? PLEASE SEE 430-150. PLEASE | | | NOTE LOAD FROM NEC IS SHOWN AT 240A`S | | | AND IS THERE ANY PF CONSIDERATION? | | | PLEASE CLARIFY LOADS ON 200HP MOTOR. | | | 3)NOTE: PLEASE CLARIFY THE LOCATION OF | | | THE 800A OCP AND ATS SHOWN ON LINE DIA- | | | -GRAM E5.103. PLEASE NOTE THAT ONLY | | | CONTROL PANEL IS SHOWN IN FIRE PUMP ROOM | | | AND ONLY THE TWO ATS`S FOR EMDP1 AND 2 | | | IS SHOWN IN MAIN ELECTRICAL ROOM. | | | | | | 4)NOTE: PLEASE NOTE THAT FROM NOTE#3 | | | FIRST REVIEW, A NOTE WAS PLACE ON E2.102 | | | "ATS IN THIS ROOM FOR SHUTOFF" PLEASE | | | CLARIFY NOTE ON PLANS SO THAT THE NOTE | | | IS MORE SPECIFIC OF MEANS OF SHUT-OFF | | | AND FOR WHAT? (GENERATOR) | | | | | | 5)NOTE: PLEASE NOTE THAT IF USING "SCALE | | | ON E4.104, PLEASE NOTE THE CLEARENCE FOR | | | MAINS ON GENERATOR/CONTROL PANEL DO NOT | | | SEEM TO MEET 110-26A "CONDITION 2" | | | PLEASE CLARIFY. | | | | | | PLEASE NOTE THAT NOTES # 1 AND #5 WERE | | | ADDRESSED FULLY. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL OR CALL FOR A MEETING IF | | | DESIRED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-14 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-14 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2001-08-14 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT GFI PROTECTION | | | OF MAINS ARE NOT SHOWN. PER 230-95 | | | PLEASE SHOW ON RISER LINE DIAGRAM AND | | | PANEL SCHEDULES FOR MSB`S. | | | | | | 2)NOTE: PLEASE PROVIDE CLARIFICATION | | | FOR MEANS OF DISCONNECT FOR FIRE PUMP. | | | FEED IS SHOWN FROM FPL TO ATS W/ NO | | | MAIN OR OCP? PLEASE CALRIFY. 695-3-A-1, | | | 230-2, 230-72B, 695-4-B-2 | | | | | | 3)NOTE: PLEASE SUBMIT CLARIFICATION FOR | | | MEANS OF SHUTTING DOWN OF GENERATOR? | | | MEANS OF DISCONNECT TO BE GROUPED W/ | | | MAINS PER 230-72, 230-76,230-79 AND | | | MARKED PER 230-2. | | | | | | 4)NOTE: PLEASE NOTE THAT OUTLET SPACING | | | TO MEET LOCAL AMENDMENST PER 210-50. | | | PLEASE NOTE SOME LOCATIONS MISSING | | | OUTLETS. STARTING ON E2.101 (IN-21),,,,, | | | | | | 5)NOTE: PLEASE PLACE DETAIL ON LINE | | | DIAGRAM FOR COLOR CODING OF FEEDERS | | | PER LOCAL COUNTY-WIDE AND CITY-WIDE | | | ADMINISTRATIVE CODE. ART215 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-05-25 |
Time |
09:49 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-05-25 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | PASSED: | | | 1. REVIEWED FOR THE SOUTHWEST FIRE DEPT. | | | ACCESS RAMP, REPALCED ASPHALT PAVING | | | SOTH OF THE GATE WITH SOD AND IRRIGATION | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-10-28 |
Time |
08:50 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-10-28 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2003-10-28 00:00:00 | PASSED: | | | 1. RVIEWED BY DEAN LAUDERMILK 10-28-03. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-10-24 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
11:37 |
Rev Time |
0.25 |
| Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-24 00:00:00 | PLAN SETS DO NOT INCLUDE CIVIL, | | | IRRIGATION OR LANDSCAPING. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
9 |
Status |
P |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-21 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-21 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-01-14 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-01-14 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | REVISION DATED 12-10-03 FOR EMERGENCY | | | LIGHTING SHEETS E1.103 AND E1.104 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-13 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2002-12-04 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
N |
Date |
2002-05-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-25 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-28 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2002-05-28 00:00:00 | 1) WHAT WILL THE SERIES 705 UL/FM | | | BUTTERFLY VALVE BE USED FOR. PLEASE | | | SEE PAGE 14 OF SUBMITTALS. | | | | | | 2) THE FIRE DEPARTMENT CONNECTION SHOWN | | | ON PAGE 18 IS TO BE COMPATIBLE WITH | | | WEST PALM BEACH FIRE RESCUE NST | | | CONNECTION. | | | | | | 3) PLEASE INDICATE LOCATION AND USE OF | | | THE GLOBE VALVES SHOWN ON PAGE 19. | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2002-02-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-26 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-26 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-11-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-29 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-29 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2001-11-29 00:00:00 | RECEIVED ORIGINAL LETTERS REGARDING | | | MEMORANDUM OF UNDERSTANDING # 1 FROM | | | HOWE ENGINEERS, INC. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-20 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-20 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-10-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-18 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-18 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-10-18 00:00:00 | 1) SOME MATH ERRORS STILL EXIST IN | | | OCCUPANT LOAD CHARTS 1 & 2. | | | 2) DO THE WALLS IN SERVICE CORRIDOR | | | 2N-28 CREATE HARD BARRIERS FOR EXITING | | | ONCE PERSONS LEAVE THE BALLROOMS VIA | | | THE EXIT DOORS. | | | 3) EMERGENCY LIGHTS STILL NOT CLEARLY | | | IDENTIFIED IN BALLROOMS AND EXHIBIT | | | HALL. | | | 4) THE FINAL REPORT FOR SMOKE CONTROL, | | | SMOKE EXHAUST IS NOT SIGNED AND SEALED. | | | ALSO THE FINAL REPORT MUST BE SUBMITTED | | | TO THE BUILDING OFFICIAL FOR HIS | | | REVIEW AND APPROVAL UNDER SEPARATE | | | COVER. PLEASE VERIFY THAT THE REPORT | | | IS THE FINAL DRAFT AND READY FOR | | | SUBMITTAL. A REVIEW OF THIS DOCUMENT | | | SUGGESTS SOME CORRELATION ISSUES STILL | | | EXIST. | | | 5) COULD NOT LOCATE EXIT # 14 ON PAGE | | | A1-4.1. | | | 6) PLEASE CLEARLY IDENTIFY THAT ALL | | | PRESCRIPTIVE CODE REQUIREMENTS HAVE BEEN | | | MET FOR THE RAMP BEING USED FOR | | | EXITING ADJACENT TO THE LOADING DOCK. | | | 7) CO2 EXTINGUISHERS NOTED ON PAGE | | | FP1-1.1. PLEASE EXPLAIN. | | | 8) ARE THE DUAL ENCLOSED STAIRS SCISSSOR | | | STAIRS OR DOUBLE STAIRS. | | | 9) WEST WALL NOT RATED ON PAGE A1-5.1 | | | 10) PLEASE BE ADVISED THAT CERTAIN | | | RESTRICTIONS APPLY TO THE USE OF WOOD | | | IN THE FIRE LIMITS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-10 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-10 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2001-08-10 00:00:00 | 1) PLEASE BE ADVISED THAT THIS BUILDING | | | IS LOCATED WITHIN THE CITY FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY. | | | 2) PLEASE BE ADVISED THAT CITY CODE | | | SECTION 11-73 PROHIBITS THE USE OF | | | OPEN FLAME DEVICES IN PUBLIC ASSEMBLY | | | OCCUPANCIES. | | | 3) PLEASE INDICATE COMPLIANCE WITH | | | PRESCRIPTIVE CODE REQUIREMENTS OF NFPA | | | 101, 2000 EDITION. | | | 4) STILL HAVE NOT RECEIVED LETTER | | | REGARDING THE NON USE OF PYROTECHNICS | | | WITHIN THE BUILDING. | | | 5) FIRE HYDRANTS NOT SHOWN ON SITE PLAN. | | | ADDITIONAL FIRE HYDRANTS HAVE BEEN | | | AGREED TO BY THE DESIGN TEAM. | | | 6) OCCUPANT LOAD CHART, LEVEL ONE ON | | | PAGE A1-4.1 IS NOT CORRECT. MATH ERRORS | | | EXIST. | | | 7) OCCUPANT LOAD CHART FOR LEVEL TWO | | | HAS THE SAME PROBLEM. | | | 8) VOID SPACE UNDERNEATH MONUMENTAL | | | STAIR ON PAGE A2-1.1, CONFIRM USE IF | | | ANY. | | | 9) PLEASE EXPLAIN USE FOR OVERHEAD DOORS | | | IN RATED FIRE WALLS. WHEN OPENED HOW | | | DO THESE DOORS CLOSE AUTOMATICALLY. | | | ARE SMOKE DETECTORS TIED INTO THESE | | | DOORS. PRODUCT APPROVALS NEEDED FOR ALL | | | OVERHEAD FIRE DOORS. DOWN ON ALL ALARMS. | | | 10) PLEASE EXPLAIN OPPOSING DOORS NEAR | | | CHILLER PLANT. | | | 11) PLEASE EXPLAIN USE OF PANTRY. | | | 12) EXPLAIN 16'-0 HIGH SLIDING METAL | | | DOORS. HOW DO THEY SLIDE WITHOUT | | | INTERFERING WITH DOORS USED FOR | | | EXITING. | | | 13) HOW DOES THE 30' HIGH OPERABLE | | | PARTITION WALL WORK. | | | 14) PLEASE EXPLAIN ONE HOUR RATED | | | CONTINOUSLY HINGED OPERABLE WALL, | | | MEETING ROOM 1E-13. | | | 15) FRT PLYWOOD TO 6'-0 AFFF IN SERVICE | | | CORRIDOR 2N-28 IS USED FOR WHAT. | | | 16) PROPOSED FURNITURE LAYOUT IN | | | PRE-FUNCTION AREAS SHOULD BE SHOWN. | | | 17) STRETCHED FABRIC WALL SYSTEMS, | | | SECOND FLOOR MEETING ROOM ENTRY, PLEASE | | | EXPLAIN. | | | 18) PLEASE PROVIDE PRODUCT APPROVALS | | | FOR TRANSOMS 1 1/2 HOUR LABELED | | | PERFORATED METAL INFILL PANELS. | | | 19) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR CEILINGS, | | | WALLS, AND FLOORS. ALSO FLAME SPREAD | | | INFORMATION REQUIRED FOR ANY CURTAINS, | | | ETC. | | | 20) PLEASE INDICATE TACTILE SIGNAGE FOR | | | EXIT DOORS. | | | 21) WHY ARE THERE NO FIRE ALARM | | | EQUIPMENT WITHIN TRANSFORMER ROOM. | | | 22) PLEASE INDICATE WHAT THE EMERGENCY | | | VOICE EVACUATION MESSAGE WILL SAY. | | | 23) ALL HOODS USED FOR THE COOKING THAT | | | PRODUCES SMOKE OR GREASE LADEN VAPORS | | | ARE TO BE CONNECTED TO THE BUILDING'S | | | FIRE ALARM SYSTEM. | | | 24) NO SPEAKER STROBES NOTED IN LOADING | | | DOCK W-07. | | | 25) STORAGE ROOM 2E-30 HAS NO SMOKE | | | DETECTOR IN IT LIKE OTHER ONES. | | | 26) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE INSTALLATION OF THE FIRE ALARM | | | SYSTEM. | | | 27) GAS INSTALLATION TO COMPLY WITH | | | NFPA 54. PLEASE NOTE THIS ON THE | | | DRAWINGS. | | | 28) WHY ARE CO2 EXTINGUISHERS PLANNED | | | FOR SOME SECTIONS INSTEAD OF ABC TYPES. | | | 29) 8" FIRE LINE SHOWN RUN UNDERFLOOR | | | IS NOT ALLOWED TO BE INSTALLED IN THIS | | | MANNER. | | | 30) PLEASE SHOW DRAFT CURTAINS AND | | | CLOSELY SPACED FIRE SPRINKLER HEADS | | | TO PROTECT ESCALATOR OPENINGS. | | | 31) NO FIRE SPRINKLER PROTECTION SHOWN | | | FOR BANQUET STORAGE 2W-14. | | | 32) THIS OFFICE WOULD ENCOURAGE THE USE | | | OF A COMPLETE WET PIPE FIRE SPRINKLER | | | SYSTEM FOR THE BUILDING INSTEAD OF SOME | | | AREAS HAVING PRE-ACTION SYSTEMS DUE | | | TO FUTURE MAINTENANCE ISSUES. | | | 33) FIRE MARSHAL SPELLED INCORRECTLY | | | ON SIGN DRAWINGS ON G3.1.0. | | | 34) PLEASE PROVIDE A TYPICAL ARRANGEMENT | | | FOR THE EXHIBIT HALL. | | | 35) PLEASE CLEARLY IDENTIFY EMERGENCY | | | LIGHT FIXTURES IN 1E-36 AND EXHIBITION | | | HALL. | | | 36) FIRE SPRINKLER PROTECTION REQUIRED | | | IN FIRE PUMP ROOM. | | | 37) A HOSE CABINET IS SHOWN IN STORAGE | | | ROOM 1N-48. | | | 38) HOW DOES THE EXIT DOORS, SOUTH ENTRY | | | LOBBY WORK WHEN PHASE TWO IS STARTED. | | | 39) ARE THERE ANY FOOD SERVICE DEVICES | | | PLANNED FOR THE EXHIBITION HALL THAT | | | WOULD PRODUCE SMOKE OR GREASE LADEN | | | VAPORS. IF THEY DO COMPLIANCE WITH | | | NFPA 96 WOULD BE REQUIRED IN THE | | | CONCESSION AREAS. | | | 40) AFTER ANOTHER REVIEW OF THE | | | EXHIBITION HALL IT WOULD APPEAR THAT | | | ADDITIONAL EXIT SIGNAGE IS NEEDED ON THE | | | WEST SIDE OF IT. | | | 41) SMOKE EVACUATION SYSTEM CALCULATION | | | FOR TOTAL VOLUME IS INCORRECT. BASED | | | ON INFORMATION SUPPLIED, IT SHOULD | | | READ 1,975,868 INSTEAD OF 1,975,328. | | | 42) HOW WILL THE SMOKE EVACUATION | | | SYSTEM BE IMPACTED FOR PHASE ONE, WHEN | | | THE FUTURE PHASE TWO CONSTRUCTION IS | | | FINISHED. | | | 43) PLEASE DEFINE "OPERATOR" WHO WILL | | | BE CAPABLE OF OVERRIDING THE SYSTEM AND | | | PLACING THE SYSTEM INTO ANY MODE AT | | | ANY TIME. | | | 44) PLEASE EXPLAIN WHY NO MANUAL | | | OPERATION WILL CAUSE THE SMOKE EXHAUST | | | SYSTEM TO OPERATE. | | | 45) THE BUILDING MANAGEMENT SYSTEM SHALL | | | NOT BE CAPABLE OF EVER OVERRIDING THE | | | REQUIRED FIRE ALARM SYSTEM OR SMOKE | | | EXHAUST SYSTEM FOR THE ATRIUM. | | | 46) RECENTLY, IT WAS EXPLAINED THAT | | | EXHUAST FANS ARE PLANNED FOR THE EXHIBIT | | | HALL. WILL THESE DEVICES BE ABLE TO BE | | | BUMPED ON BY FIRE RESCUE TO EXHAUST | | | SMOKE OR POSSIBLE PYROTECNIC RESIDUE IF | | | APPROVED BY FIRE RESCUE. | | | 47) PLEASE INDICATE WHAT THE WARNING | | | SIGNAGE FOR THE CHILLER PLANT WILL SAY | | | AND WHAT LOCATIONS WILL THEY BE PLACED. | | | 48) NO FIRE SEPARATION SHOWN ON WALL | | | BETWEEN LOADING DOCK AND WEST WALL | | | OF EXHIBIT HALL. ALSO THE SECOND FLOOR | | | SAME LOCATION. SOUTH WALL ALSO. | | | 49) PLEASE EXPLAIN SIDELIGHTS SHOWN FOR | | | WALLS ON A5-1.1. | | | 50) HOW IS EXITING GOING TO BE DEFINED | | | FROM THE ASSEMBLY TO THE LOADING DOCK | | | AREA. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
64 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-20 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-20 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2004-05-20 00:00:00 | TO COMM BD#26 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
63 |
Status |
N |
Date |
2004-05-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-20 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-19 |
Time |
13:09 |
Sent To |
Z |
|
| Notes |
| 2004-05-19 00:00:00 | TO ERIC SCHNEIDER VIA MM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
62 |
Status |
N |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-07 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-07 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
| 2004-04-07 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
61 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-09 |
Time |
09:11 |
Sent To |
E |
|
| Notes |
| 2004-01-09 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
60 |
Status |
N |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-08 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-06 |
Time |
10:58 |
Sent To |
Z |
|
| Notes |
| 2004-01-06 00:00:00 | TO ERIC SCHNEIDER/PLANNING/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
59 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2003-12-19 00:00:00 | TO LM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
58 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
09:52 |
Sent To |
B |
|
| Notes |
| 2003-12-16 00:00:00 | TO LM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
57 |
Status |
N |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-10 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
| 2003-12-10 00:00:00 | TO LM DESK/SUBMITTAL SE CANOPY FRAMING | | | HANDRAIL CALCS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
56 |
Status |
N |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-05 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2003-12-05 00:00:00 | TO MIKE SIZEMORE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
55 |
Status |
N |
Date |
2003-12-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-05 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-05 |
Time |
08:27 |
Sent To |
B |
|
| Notes |
| 2003-12-05 00:00:00 | TO LM DESK/RFI'S 1393-1393A |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
54 |
Status |
N |
Date |
2003-11-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-26 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-26 |
Time |
09:02 |
Sent To |
E |
|
| Notes |
| 2003-11-26 00:00:00 | TO DP/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
53 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2003-11-06 00:00:00 | REC'D POLLUTION CONTROL PLAN INSPECT | | | GAVE TO LM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
52 |
Status |
N |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-03 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-03 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | TO COMM BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
51 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | TO LM DESK/SIGNAGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
50 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
14:11 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | TO LM DESK SUBMITTA; - SIGN FOOTING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
49 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
14:10 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | TO LM DESK/FLAG POLE SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
48 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2003-10-22 00:00:00 | TO DON NEELY/SUBMITTAL-POLLUTION CONTROL | | | PLAN INSP & MTNC REPT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
47 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | TO LM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
46 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-22 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-22 |
Time |
13:58 |
Sent To |
B |
|
| Notes |
| 2003-10-22 00:00:00 | TO LM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
45 |
Status |
N |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-21 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-21 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
| 2003-10-21 00:00:00 | TO LM DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
44 |
Status |
N |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-16 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2003-10-16 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
43 |
Status |
N |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-09-10 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-09-10 |
Time |
15:08 |
Sent To |
E |
|
| Notes |
| 2003-09-10 00:00:00 | TO DPALMER DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
42 |
Status |
N |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-09-10 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-09-10 |
Time |
15:05 |
Sent To |
B |
|
| Notes |
| 2003-09-10 00:00:00 | TO LMARTINEZ DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
41 |
Status |
N |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-08-29 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-08-29 |
Time |
10:47 |
Sent To |
B |
|
| Notes |
| 2003-08-29 00:00:00 | METAL SUNSHADE TRELLIS | | | TO LM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
40 |
Status |
N |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-29 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-29 |
Time |
09:54 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
39 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-25 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
| 2003-08-25 00:00:00 | TO LM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
38 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-31 |
Time |
09:07 |
Sent To |
B |
|
| Notes |
| 2003-07-31 00:00:00 | TO LM DESK 7/31/03ALANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
37 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-17 |
Time |
11:38 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
36 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-17 |
Time |
11:37 |
Sent To |
ENG |
|
| Notes |
| 2003-07-17 00:00:00 | SUBMITTAL, POLLUTION CONTROL PLAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
35 |
Status |
N |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-14 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-14 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2003-07-14 00:00:00 | LMARTINEZ DESK, 2 SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
34 |
Status |
N |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-11 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-11 |
Time |
10:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
33 |
Status |
N |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-07 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-07 |
Time |
10:20 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-01 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-01 |
Time |
15:39 |
Sent To |
B |
|
| Notes |
| 2003-07-01 00:00:00 | LMARTINEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
10:18 |
Sent To |
ENG |
|
| Notes |
| 2003-06-23 00:00:00 | 3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-10 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-10 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2003-06-10 00:00:00 | LUIS MARTINEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-19 |
Time |
10:08 |
Sent To |
E |
|
| Notes |
| 2003-05-19 00:00:00 | DP DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-16 |
Time |
10:53 |
Sent To |
ENG |
|
| Notes |
| 2003-05-16 00:00:00 | SUBMITTAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-15 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-15 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | COMM BOARD #64 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-13 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-13 |
Time |
16:37 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-11 |
Time |
14:54 |
Sent To |
E |
|
| Notes |
| 2003-04-11 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-11 |
Time |
13:50 |
Sent To |
B |
|
| Notes |
| 2003-04-11 00:00:00 | LMARTINEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-11 |
Time |
13:50 |
Sent To |
B |
|
| Notes |
| 2003-04-11 00:00:00 | LMARTINEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-31 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-31 |
Time |
13:03 |
Sent To |
B |
|
| Notes |
| 2003-03-31 00:00:00 | SUBMITTALS TO LM DESK | | | | | | 1.)POLLUTION CONTROL PLAN - INSPECTION | | | AND MAINT REPORT FOR WEEK ENDING 3/21/03 | | | 2.)POLLUTION CONTROL PLAN - INSPECTION | | | AND MAINT REPORT FOR 3/24 RAINFALL EVENT | | | 3.)POLLUTION CONTROL PLAN - INSPECTION | | | AND MAINT REPORT FOR 3/27 RAINFALL EVENT | | | 4.)ANALYSIS OF SMOKE CONTROL/SMOKE | | | EXHAUST |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-19 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-19 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2003-03-19 00:00:00 | SUBMITTALS (6) - | | | | | | 1.)KITCHEN EQUIPMENT SHOP DRAWINGS - | | | SENT TO LM DESK | | | | | | 2.)KITCHEN EQUIPMENT SHOP DRAWINGS - | | | SENT TO LM DESK | | | | | | 3.)THERMOSTATIC MIXING VALVE - SENT | | | TO PLUMBING | | | | | | 4.)SPLIT DX UNIT SUBMITTALS - SENT | | | TO MECHANICAL | | | | | | 5.)POLLUTION PREVENTION PLAN - SENT | | | TO LM DESK | | | | | | 6.)LIGHTING CONTROL - SENT TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2003-03-12 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-12 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-12 |
Time |
16:34 |
Sent To |
E |
|
| Notes |
| 2003-03-12 00:00:00 | SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-10 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-10 |
Time |
09:38 |
Sent To |
B |
|
| Notes |
| 2003-03-10 00:00:00 | TO LM`S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-10 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-10 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
| 2003-03-10 00:00:00 | TO LM `S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-06 |
Time |
10:33 |
Sent To |
B |
|
| Notes |
| 2003-03-06 00:00:00 | TO LM`S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-06 |
Time |
10:32 |
Sent To |
B |
|
| Notes |
| 2003-03-06 00:00:00 | TO LM`S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-26 |
Time |
09:15 |
Sent To |
B |
|
| Notes |
| 2003-02-26 00:00:00 | SUBMITTAL TO LOU M. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-10 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-10 |
Time |
10:23 |
Sent To |
B |
|
| Notes |
| 2003-02-10 00:00:00 | TO LOU M'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2003-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-29 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-29 |
Time |
16:12 |
Sent To |
B |
|
| Notes |
| 2003-01-29 00:00:00 | TO LM DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-27 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-27 |
Time |
11:21 |
Sent To |
FIRE |
|
| Notes |
| 2003-01-27 00:00:00 | TO FIRE REVIEW INBOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-10 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-10 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
| 2003-01-10 00:00:00 | TO LUIS M./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-10 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-10 |
Time |
16:21 |
Sent To |
B |
|
| Notes |
| 2003-01-10 00:00:00 | TO LUIS M./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2002-12-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-06 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-06 |
Time |
16:32 |
Sent To |
B |
|
| Notes |
| 2002-12-06 00:00:00 | TO HAROLD P./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-05 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-05 |
Time |
17:29 |
Sent To |
B |
|
| Notes |
| 2002-12-05 00:00:00 | TO HAROLD P./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2002-12-04 |
Time |
17:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2002-11-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-27 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-27 |
Time |
12:03 |
Sent To |
B |
|
| Notes |
| 2002-11-27 00:00:00 | TO HAROLD P./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2002-11-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-22 |
Time |
17:33 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-13 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-11-13 |
Time |
16:30 |
Sent To |
B |
|
| Notes |
| 2002-11-13 00:00:00 | TO LOU MARTINEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-06 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-06 |
Time |
16:42 |
Sent To |
B |
|
| Notes |
| 2002-11-06 00:00:00 | TO HAROLD P./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-30 |
Time |
12:33 |
Sent To |
FIRE |
|
| Notes |
| 2002-10-31 00:00:00 | TO FIRE./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-29 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-10-28 |
Time |
07:09 |
Sent To |
B |
|
| Notes |
| 2002-10-29 00:00:00 | SUBMITTALS, TO LOU M. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
16 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-11-04 |
Time |
16:56 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-11-04 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
15 |
Status |
P |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-10-29 |
Time |
17:19 |
Rev Time |
1.50 |
| Received By |
hmoser |
Date |
2003-10-29 |
Time |
17:19 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
14 |
Status |
P |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-09-15 |
Time |
14:34 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-09-15 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2003-09-15 00:00:00 | MIKE SIZMORE AND HAROLD MOSER HAD A MEET | | | ING MONDAY 9/15/03.MIKE TALKED TO NEAL | | | MELICK.YOU DO NOT NEED STAMPED LETTER | | | FROM SIMPLEXGRINNELL ON LOCATION OF DUCT | | | MOUNTED SMOKE DETECTORS. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
13 |
Status |
F |
Date |
2003-08-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-08-09 |
Time |
06:46 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-08-09 |
Time |
06:46 |
Sent To |
|
|
| Notes |
| 2003-08-09 00:00:00 | PLAN DENIED | | | DO TO THE LETTER FROM SIMPLEXGRINNEL | | | THE CITY CAN NOT DETERMIN THE ACTUAL | | | PLACEMENT OF THE DUCTDETECTOR. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
12 |
Status |
P |
Date |
2003-04-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-04-12 |
Time |
11:14 |
Rev Time |
1.50 |
| Received By |
hmoser |
Date |
2003-04-12 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2003-04-12 00:00:00 | SUBMITHALS FOR SPLIT DXUNIOT OK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
11 |
Status |
P |
Date |
2002-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-11 |
Time |
07:30 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-08-06 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2002-08-06 00:00:00 | SUBMITTALS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2002-05-29 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2002-05-29 |
Time |
12:46 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2002-05-29 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2002-05-29 00:00:00 | REVISIONS REQUIRED BY THE RFI'S ARE TO | | | BE SUBMITTED ON THE APPROPRIATE PLAN | | | PAGES AS REQUIRED TO SHOW CHANGES ON | | | DRAWINGS. | | | | | | NANCY DENMARK | | | CHIEF MECHANICAL INSPECTOR | | | (561) 659-8096 EXT. 8221 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2002-04-30 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2002-04-30 |
Time |
12:49 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2002-04-30 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2002-04-30 00:00:00 | SKM-2 AND SKM-3 REVISEDSKM-3 REPLACES | | | SKM-1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2002-04-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-02 |
Time |
14:58 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-04-02 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2002-04-02 00:00:00 | SUBMITTAL FOR: | | | | | | CHILLERS, PUMPS, SUCTION DIFFUSER, RELIE | | | F VALVES, AIR SEPARATOR |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2002-03-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-12 |
Time |
14:35 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-03-12 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2002-03-12 00:00:00 | REVISION TO PLAN SHEET M2.103, M2.104, | | | M2.203, M2.204, M2.207, & M2.208. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-11-20 |
Time |
08:43 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-11-20 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2001-11-20 00:00:00 | PROVISO: | | | 3 ORIGINAL SIGNED COPIES OF THE MEMO OF | | | UNDERSTANDING AUTHORED BY JIM HOWE TO BE | | | SET TO THIS OFFICE FOR INCLUSION IN | | | THE FILE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-11-14 |
Time |
09:41 |
Rev Time |
1.50 |
| Received By |
ndenmark |
Date |
2001-11-14 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2001-11-14 00:00:00 | THE FOLLOWING ITEMS NED TO BE CLARIFIED: | | | | | | 1. M2.207 FIRE DAMPER REQUIRED FOR | | | TRANSFER OPENING IN ELEC. RM 2E-16 WEST | | | WALL BY COLUMN 16 AND S. | | | 2. WHAT TYPE OF FUEL SUPPLY IS TO BE | | | USED FOR THE GENERATOR AND HOW MUCH ON | | | SITE STORAGE? | | | 3. WALLS REQUIREING RATING SHALL HAVE | | | OPENING PROTECTION PER 1997 SMC 610. | | | 4. NFPA 37 CH 5 REQUIRES RATING OF | | | GEERATOR RM WALLS. | | | 5. PLAN SHOWS 2 HR RATING OF GENERATOR | | | RM WALLS. | | | 6 CAN WE ACCEPT THE HOWE REPORT FOR | | | SMOKE CONTROL IF NOT SIGNED/ SEALED BY | | | STATE OF FLORIDA ENGINEER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2001-10-12 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-10-12 |
Time |
14:14 |
Rev Time |
2.00 |
| Received By |
ndenmark |
Date |
2001-10-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2001-10-12 00:00:00 | ****ATRIUM SMOKE CONTROL**************** | | | | | | THE FOLLOWING QUESTIONS NEED TO BE | | | ADDRESSED . | | | 1. WHY NOT USE MANUAL PULL TO INITIATE | | | ATRIUM SMOKE CONTROL SYSTEM? | | | 2. PAGE 19 OF 57 ZONE 3 SHOWS A 6 FT | | | HEIGHT FOR SMOKE FOR THE GRADE LEVEL | | | AND FOR THE BALLROOM PREFUNCTION AREA. | | | THIS CONFLICTS WITH PRIOR STATEMENTS TO | | | MAINTAIN A 10 FOOT TENABLE HEIGHT. | | | 3. PAGE 30 SHOWS NO SMOKE BEING USED AND | | | PAGE 34 INDICATES A SMOKE PRODUCTION | | | METHOD. BE ADVISED THE ACCEPTANCE | | | TEST WILL REQUIRE SMOKE TO BE USED AS | | | PART OF THE CRITERIA TO ACCEPT THE | | | SMOKE CONTROL SYSTEM. | | | 4.PROVIDE A DIAGRAM OF THE SMOKE CONTROL | | | PANEL FOR REVIEW. | | | 5. PROVIDE A COPY OF THE FINAL APPROVED | | | CITY STAMPED ANALYSIS OF SMOKE CONTROL/ | | | SMOKE EXHAUST PRIOR TO THE ACCEPTANCE | | | TEST FOR INSPECTORS REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2001-10-12 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-10-12 |
Time |
10:53 |
Rev Time |
4.00 |
| Received By |
ndenmark |
Date |
2001-10-12 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2001-10-12 00:00:00 | *******REVIEW DOES NOT INCLUDE SMOKE | | | CONTROL SYSTEM************************* | | | DENIED | | | 1.M2.106 NO FIRE DAMPERS SHOWN IN RATED | | | WALL DIFFUSER PENETRATIONS AT ALCOVE BY | | | COLUMNS T AND U AND 8 AND 9. | | | 2. FIRE DAMPER NOT SHOWN AT RATED WALL | | | PENETRATION OF 16X18 DUCT BY | | | COLUMN LINE 4 AND C.8 M2.201 | | | 3. FIRE DAMPERS NOT SHOWN M2.202 AT | | | PENETRATION OF 28 X 20 DUCT BY COLUMN G | | | AND ( AND ELECTRIC ROOOM 14X 8 DUCT | | | PENETRATION SAME AREA | | | 4. M2.202 TELEPHONE ROOM 2N31 APPEARS TO | | | AHVE RATED WALL PENETRATION BY 8X8 | | | DUCT. | | | 5.M2.208 NO FIRE DAMPERS SHOWN AT 2 DUCT | | | PENETRATIONS BY COLUMN U AND 21 AND NO | | | FIRE DAMPER SHOWN AT 18X 20 DUCT BY U | | | AND 20. | | | 6 M2.102 TRANSFER AIR NEEDS TO BE FROM | | | SATELLITE ROOM AS WELL AS IN DOOR N40-1 | | | 7. M 2.106 FIRE DAMPER REQUIRED IN 6" | | | SUPPLY TO 1N68, SHOW MANAGERS OFFICE | | | 8> M2.107 NO FIRE DAMPER SHOWN IN 16X6 | | | TRANSFER DUCT IN STORAGE RM 1E-28 EAST | | | WALL | | | 9. PREVIOUS COMMENT ON VAULT ROOM | | | OPENINGS REFER TO LOUVER OPENINGS IN | | | REQUIRED RATED WALLS. THIS WOULD ALSO | | | INCLUDE THE GENERATOR ROOM. | | | 10. PLUMBING CONNECTION OF CONDENSATE | | | DRAINS TO STORM SEWER TO BE PER | | | PLUMBING APPROVAL. | | | | | | SEE MECH REVIEW # 4 FOR SMOKE CONTROL | | | COMMENTS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-08-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-06 |
Time |
14:09 |
Rev Time |
5.00 |
| Received By |
ndenmark |
Date |
2001-08-06 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2001-08-06 00:00:00 | REVIEW FOR SMOKE CONTROL SYSTEM FOR | | | ATRIUM | | | ***************DENIED******************* | | | 1. PLEASE CLARIFY MAXIMUM ATRIUM HEIGHT | | | AS WE HAVE TWO DIFFERENT STATEMENTS AS | | | TO HEIGHT. | | | 2. PROVIDE SEQUENCE OF OPERATION FOR | | | DOOR OPENINGS AND ATRIUM SMOKE CONTROL | | | 3. DURING THE ORIGINAL MEETING ON SMOKE | | | CONTROL THE BUILDING OFFICIAL REQUESTED | | | IF YOU WERE USING AN ALTERNATIVE METHOD | | | TO THE SBC USE THE 10 FOOT ABOVE THE | | | SECOND FLOOR NOT THE 6 FOOT AS SHOWN IN | | | THE REPORT. | | | 4. ALL ELEVATIONS OPENING TO THE ATRIUM | | | ARE NOT INDICATED AS REQUESTED IN THE | | | FIRST SET OF COMMENTS. PROVIDE | | | INFORMATION ON THE ELEVATIONS INVOLVED, | | | I,E. AREAS SHOWN AS OPEN TO BEYOND BY | | | BALLROOM CONCOURSE BETWEEN COLUMNS U | | | AND K. | | | 5. ARE ALL RESTROMS, THE ADMINISTRATIVE | | | ASSISTANT (1N-49), RECEPTION AREA | | | (1N-50) AND ANY OTHER AREA NOT | | | SEPARATED BY RATED WALLS INCLUDED IN | | | THE ATRIUM SIZE CALCULATION? | | | 6. AS PART OF THE SEQUENCE OF OPERATION, | | | PROVIDE INFORMATION ON ALL DEVICES THAT | | | WILL INITIATE THE SMOKE CONTROL SYSTEM. | | | 7. INDICATE IN THE SEQUENCE OF OPERATION | | | HOW THE DIFFERENT FANS AND DOORS IN THE | | | DIFFERENT ZONES WILL OPERATE. WILL ALL | | | DOORS OPEN AND ALL FANS COME ON AR ONLY | | | THOSE IN EFFECTED AREAS? | | | 8.SHOW FIREMANS OVERRIDE PANEL AND | | | EXPLAIN FUNCTION. | | | 9. ON SHEET M5.103 SEQUENCE OF OPERATION | | | SAYS THAT OPERATOR WILL BE ABLE TO | | | OVERRIDE THE SYSTEM AT ANY TIME. DEFINE | | | OPERATOR IN THIS STATEMENT. | | | 10. IF FANS OPERATE PRIOR TO DOOR | | | OPENING, PROVIDE INFORMATION ON DOOR | | | PRESURE. PROVIDE MAXIMUM DOOR PULL | | | PRESSURES FOR ALL EXIT DOORS NOT OPENED | | | AS PART OF THE SMOKE CONTROL SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-02 |
Time |
12:01 |
Rev Time |
14.00 |
| Received By |
ndenmark |
Date |
2001-08-02 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | **************DENIED******************** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS | | | PRIOR TO RESUBMITTAL OF PLANS. | | | 1.THE DUCT BANK DETAIL SHOWN ON A1-17 | | | SHOWS DUCT ON COMPACTED EARTH. !997 SMC | | | 607 REQUIRES MECHANICAL DUCT TO BE | | | ENCLASED ON ALL SIDES WITH NOT LESS | | | THAN 2" OF CONCRETE. | | | 2. THE LOUVER OPENING FOR GENERATOR ROOM | | | SHOWN ON A2-1.3 ARE REQUIRED TO BE | | | PROTECTED BY APPROVED FIRE DAMPERS TO | | | MAINTAIN THE RATING OF THIS ROOM. | | | PROVIDE INFORMATION ON OPENING | | | PROTECTION. | | | 3. DOES THE PROJECTION EQUIPMENT SHOWN | | | ON A3-1.6 REQUIRE ADDITIONAL | | | VENTILATION OR EXHAUST? PROVIDE | | | MANUFACTURES RECOMMENDATIONS ON | | | EQUIPMENT REQUIREMENTS. | | | 4. OVERHEAD DOORS SHOWN IN RATED WALLS | | | WILL BE REQUIRED TO HAVE AUTOMATIC | | | CLOSURE ABILITY TO PROTECT OPENING. | | | PROVIDE INFORMATION ON DOOR FUNCTION TO | | | COMPLY WITH REQUIREMENTS FOR OPENING | | | PROTECTION. | | | 5. PLAN SHOWS VEHICLE ACCESS TO SECOND | | | FLOOR. WHAT REQUIREMENTS FOR ADDITONA | | | OUTSIDE AIR OR MONITORING FOR CARBON | | | MONOXIDE DOES THIS ADD TO THE FACILITY? | | | PROVIDE CALCULATIONS SHOWING WORST CASE | | | LOAD OF VEHICLES. | | | 6. NO INFORMATION WAS SHOWN FOR DISPOSAL | | | OF CONDENSATE FROM AIR HANDLING | | | EQUIPMENT. PROVIDE LOCATION AND SIZES | | | OF THIS PIPING AND DISPOSAL LOCATION. | | | NOTE: LOCAL ORDINACE DOES NOT PERMIT | | | CONDENSATE TO GO TO THE SANITARY SYSTEM. | | | 7. CHILLER SPECS ON M 0.002 SHOW | | | EFFIENCY RATING AS NLPV. FLORIDA ENERGY | | | CODE REQUIRES RATING IN ILPV. PLEASE | | | PROVIDE CHILLER RATING AS ILPV NUMBER | | | COMPLYING WITH TABLE 4-5 MINIMUM | | | PERFORMANCE EFFICIENCIES. | | | 8. ENERGY CALCS SHOW 4 SYSTEMS WITH | | | VARIOUS EFFICIENCIES. NOT ALL EQUIPMENT | | | APPEARS TO BE LISTED IN CALCS PROVIDED. | | | SHOW ALL EQUIPMENT TO BE INSTALLED OR | | | SUMMARY AS PROVIDED FOR IN FLA ENERGY | | | CODE, | | | 9. M0.002 AIR BALANCE EXHAUST AND | | | OUTSIDE AIR VALUES DO NOT ADD UP TO | | | EQUIPMENT VALUES SHOWN. PROVIDE AIR | | | BALANCE SCHEDULE SHOWING COMPLIANCE | | | WITH 1997 SMC 501.2 AND OUTSIDE AIR | | | CALCULATIONS SHOWING COMPLIANCE WITH | | | ASHRAE 62.89. | | | 10. OUTSIDE AIR REQUIRED FOR TICKET | | | OFFICE NEEDS TO BE DUCTED TO THE RETURN | | | AIR OF THE UNIT SERVING THIS SPACE FOR | | | BALANCING PURPOSES | | | 11.WOMEN'S AND MEN'S BATHROOMS AND | | | LOCKER ROOMS SHOWN ON M2.101 HAVE 1400 | | | CFM OF EXHAUST AIR AND ONLY 200 CFM OF | | | SUPPLY AIR. ANOTHER AREA HAS 600 CFM | | | EXHAUST AND 100 S/A. RM 1N23+ 24 HAVE | | | 3050 EXHAUST AIR AND 850 SUPPLY AIR. | | | PROVIDE AIR BALANCE IN COMPLIANCE WITH | | | 1997 SMC 501.2 | | | 12. NO RETURN AIR IS SHOWN IN SATELLITE | | | ROOM 1N53 AND IN ROOM 1N-57 S/A IS 100 | | | CFM AND R/A IS 10CFM. | | | 13. ADMIN AREA (1N64 HAS 850CFM S/A AND | | | 920 CFM R/A AND RMS 1N59/60 HAS 530 CFM | | | EXHAUST AIR AND 100 CFM S/A. | | | 14. NO RETURN AIR SHOWN FOR DOCK OFFICE | | | 1N-39 ANY AREA WITH 350 CFM OR MORE | | | NEEDS RETURN FROM ROOM. | | | 15. MACHINE ROOM HAS 490 CFM OF EXHAUST | | | AIR AND NO PROVISION FOR MAKE UP AIR. | | | SHOW COMPLIANCE WITH SMC 501.2. | | | 16. NO FIRE DAMPERS SHOWN AT FLOOR | | | PENETRATIONS OF DUCT ON M 2.104 | | | 17. WOMEN'S ROOM 1C 17 AND 14 HAVE 670 | | | CFM OF EHAUST AND 310 CFM MAKE UP AIR | | | INCLUDING U/C OF DOOR. | | | 18. ON M 2.106 NO FIRE DAMPERS SHOWN IN | | | EAST WALL OF SHOW AMANGERS | | | OFFICE(1N-68)AT DUCT PENETRATION. | | | 19. NO PROTECTION OF WALL PENETRATIONS | | | SHOWN FOR TRANSFER GRILLS, DOOR GRILLS, | | | AND OVERHEAD DOORS ON WEST SIDE OF | | | SERVICE CORRIDOR RATED WALL BETWEEN | | | COLUMN S AND T ON M2.107 | | | 20. NO FIRE DAMPERS SHOWN IN RATED WALL | | | AT COLUMN V DUCT PENETRATIONS CLOSE TO | | | AREA 7 AND 8 MATCH LINE. | | | 21. M2.201 MEN,S ROOM 2N-15 HAS 740 CFM | | | E/A AND 485CFM MAKE UP AIR INCLUDING | | | DOOR GRILL. JANITOR'S CLOSET HAS 140 | | | CFM E/A AND 590 CFM MAKE UP(INTO MEN'S | | | ROOM). | | | 22. SYMBOL FOR DUCT ELEVATION CHANGE | | | DIFFERS FROM LEGEND TO WHATS USED ON | | | DRAWINGS. | | | 23. NO COMBUSTIBLES ALLOWED IN RETURN | | | AIR PLENUM AREAS. | | | 24. M2.201 CLARIFY WHICH WALL IS RATED | | | AT ELEC AND TELE RMS 2N-12 AND 10. GAP | | | ON HOURLY RATED WALL PLAN A1-5.2. DUCTS | | | PENETRATE SOUTH WALL W/ NO FIRE DAMPERS | | | SHOWN BY COLUMNS C.8 AND 4 AT 16X18" | | | DUCT PENETRATION. | | | 25. M2.201 NO FIRE DAMPER SHOWN BY | | | COLUMN J AND 4 AT 14" DUCT PENETRATION | | | 26. WOMEN'S BATH AND LOCKER ROOM ON | | | M2.202 HAS 500 CFM TOTAL EXHAUST AND | | | 250 CFM OF MAKE UP AIR | | | 27. NO FIRE DAMPERS SHOWN ALONG RATED | | | SERVICE CORRIDOR 2N-28 X 10 PLACES ON | | | M2.202. DOOR GRILLS ARE NOT SHOWN AS | | | RATED. FLOOR CEILING PENETRATIONS TO BE | | | PROTECTED BY 1997 SMC 610. | | | 28. M2.203 AND 4 NO FIRE DAMPERS | | | INDICATED AT STAIR 8 RATED WALL 10X16 | | | DUCT PENETRATION COLUMN C.7. | | | ARE MECH ROOM 2W-15, 2W-16 AND 2W-18 | | | WALLS RATED? PLAN SHOWS DASHED LINES | | | BUT NO FIRE DAMPERS AT DUCT | | | PENETRATIONS. | | | 29. M 2.207 ELECTRIC ROOM 2E-16 HAS 575 | | | CFM OF SUPPLY AIR BUT NO RETURN AIR PATH | | | FROM ROOM. PROVIDE RETURN AIR PER SMC | | | 501.2 | | | 30. M2.207 NO FIRE DAMPERS SHOWN AT | | | RATED WALL DUCT PENETRATION 18X20 DUCT | | | BY COLUMN 16 18X20 DUCT COLUMN 15 AND | | | 10X6 DUCT COLUMN T | | | 31. M2.208 NO FIRE DAMPERS SHOWN AT 6X6 | | | DUCT INTO STORAGE ROOM 2E-30 RATED WALL | | | PENETRATION. | | | 32. M3.201 NO FIRE DAMPER SHOWN AT 10X6 | | | DUCT AND 18X20 DUCT INTO MECH ROOM. | | | 33. M3.202 SHOW FIRE DAMPERS AT DUCT | | | PENETRATIONS IF WALLS ARE RATED. | | | 34. PROVIDE INFORMATION ON TYPE AND | | | QUANTITY OF REFRIGERANT PER CHILLER. | | | TYPE DETERMINES SETPOINT FOR | | | REFRIGERANT LEAK DETECTION SYSTEM. | | | 35. M5.104 OUTSIDE AIR REQUIRED BY | | | ASHRAE 62.89 SHALL NOT BE REDUCED BY | | | CO2 SENSORS. PROVIDE INFORMATION ON | | | FUNCTION OF CO2 SENSOR. | | | 36.DUCT SMOKE DETECTOR IN RETURN AIR | | | SHALL BE PRIOR TO ANY MIXINF OF OUTSIDE | | | AIR. | | | 37. NOTE DO NOT RUN AIR CONDITIONING | | | EQUIPMENT UNTIL CONSTRUCTION IS | | | FINISHED AND CITY MECHANICAL INSPECTOR | | | APPROVAL IS GIVEN. | | | 38. MAINTAIN CLEANLINESS OF DUCT DURING | | | CONSTRUCTION. | | | 39. CONDENSATE DRAIN LINES ARE NOT | | | SHOWN. | | | 40. FIRE DAMPERS WILL BE REQUIRED TO | | | MAINTAIN RATING OF VAULT ROOM THREE | | | HOUR WALLS. | | | 41. CONDENSING EQUIPMENT FOR | | | COOLERS/FREEZERS SHALL NOT BE IN THE | | | COOL AIR STREAM OF ANOTHER UNIT. ENERGY | | | EFFICIENCY REQUIREMENTS FOR FLORIDA | | | 407.1 | | | 42. EXHAUST WILL BE REQUIRED IN AREA OF | | | MOP SINKS SHOWN ON FS 2.1 C-32 | | | CONCESSION PER 1997 SMC 501.4 | | | THIS DOES NOT INCLUDE REVIEW COMMENTS | | | FOR THE ATRIUM SMOKE CONTROL SYSTEM. | | | 43. CLEARLY INDICATE IF THE DAMPER IS A | | | SMOKE FIRE DAMPER, FIRE DAMPER OR SMOKE | | | DAMPER ON THE PLAN. THE LOCATION OF ALL | | | REQUIRED DAMPERS ARE REQUIRED TO BE | | | CLEARLY INDICATED ON THE PLAN BY THE | | | DESIGNER BY 1997 610.6. | | | 44. FLOOR DRAINS INDICATED FOR THE | | | CHILLER PLANT WILL NOT BE PERMITTED IF | | | THEY WOULD ALLOW FOR THE SPREAD OF | | | REFRIGERANT LEAK FROM ONE PART OF THE | | | BUILDING TO ANOTHER. | | | 45. CLEARLY INDICATE ON PLAN THE | | | LOCATION OF THE CHILLERS RELIEF PIPE | | | TERMINATION SHOWING COMPLIANCE WITH | | | 1997 SMC 1105.9 | | | 46. HORN AND STROBE FOR CHILLER ROOM | | | REFRIGERANT LEAK DETECTORS SHALL BE | | | LOCATED INSIDE AND OUTSIDE THE ROOM | | | INAREAS WHERE THEY CAN BE SEEN AND | | | HEARD. | | | 47. THE BREATHING APPERATUR REQUIRED | | | WILL NEED TO BE LOCATED OUTSIDE OF THE | | | CHILLER ROOM. | | | 48. THE SINGLE DOOR AT THE BACK OF THE | | | CHILLER ROOM NEEDS TO HAVE SIGNS | | | PROHIBITING ACCESS IN CASE OF A LEAK | | | AND EXPLAINING THE DESIRED PROCEDURE. | | | 49. SIGNS AS REQUIRED BY SMC CH 11 AND | | | ASHREA 15 WILL BE REQUIRED. | | | 50 ACCEPTANCE OF THE REFRIGERANT LEAK | | | DETECTION WILL NEED TO BE BY TEST IN | | | THE PRESENCE OF THE MECHANICAL | | | INSPECTOR AND THE FIRE INSPECTOR,PRIOR | | | TO LOADING OF REFIGERANT INTO THE | | | CHILLERS OR IF THE CHILLERS ARE SHIPPED | | | LOADED, PRIOR TO START UP. | | | 51. ROOF PLAN SHOWS A SF AND EF | | | TOGETHER. WHAT TYPE EQUIPMENT IS THIS | | | AND HOW DOES IT COMPLY WITH THE CODE | | | REQUIRED TEN FOOT SEPARATION FROM EACH | | | OTHER. | | | 52. WHAT IS THE FUNCTION OF SEF 8? IT | | | APPEARS TO BE IN THE AREA OF THE | | | SERVICE CORRIDOR, WHICH DOES NOT APPEAR | | | TO BE PART OF THE ATRIUM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
15 |
Status |
P |
Date |
2003-07-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-19 |
Time |
06:24 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-07-19 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2003-07-19 00:00:00 | SUBMITTAL OK - CHAINWHEELACTIVATOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
14 |
Status |
N |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-14 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | THIS SUBJECT HAS BEEN ADDRESSED AT MOST | | | OF THE MEETINGS HELD AT THE CONSTRUCTION | | | SERVICES CONFERENCE ROOM. THE ANSWER | | | GIVEN AT EACH MEETING IS THE SAME AS IT | | | WILL BE NOW. THE FIRE LINE DISCHARGE | | | SHALL DRAIN INTO THE SANITARY SYSTEM AND | | | NOT THE STORM SYSTEM. SECTION 90-203(A) | | | STATES, GENERAL PROHIBITION. EXCEPT AS | | | PROVIDED IN SECTION 90-205 AND EXCEPT | | | PURSUANT TO A VALID NPDES PERMIT, IT | | | SHALL BE UNLAWFUL FOR ANY PERSON TO | | | DIRECTLY OR INDIRECTLY DEPOSIT, DIS- | | | CHARGE, SPILL OR DUMP INTO ANY OF THE | | | PUBLIC WATERS OR MUNICIPAL SEPARATE | | | STORM SEWER SYSTEM WITHIN THE CITY, ANY | | | SUBSTANCE OTHER THAN THAT COMPOSED | | | ENTIRELY OF STORMWATER. | | | I HOPE THIS WILL BE SUFFICIENT TO PUT | | | AN END TO THIS MATTER. THE DISCHARGE OF | | | THE FIRE LINES SHALL BE DRAINED TO THE | | | CITY SANITARY SYSTEM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
13 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-24 |
Time |
13:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-24 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | SUBMITTALS OK - MIXING VALVES FOR W/H'S |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
12 |
Status |
P |
Date |
2003-03-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-01 |
Time |
15:33 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-01 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2003-03-01 00:00:00 | SUBMITTALS OK - ACCESS PANEL DOORS - | | | EXPANSION TANKS - KITCHEN EQUIPMENT SHOP | | | DRAWINGS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-30 |
Time |
17:29 |
Rev Time |
0.10 |
| Received By |
kstevens |
Date |
2003-01-30 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2003-01-30 00:00:00 | SUBMITTAL OK - TRENCH DRAINS W/GALV. | | | STEEL GRATES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
F |
Date |
2003-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-22 |
Time |
13:36 |
Rev Time |
0.10 |
| Received By |
kstevens |
Date |
2003-01-22 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2003-01-22 00:00:00 | SUBMITTAL DENIED - IN-LINE BOOSTER PUMB | | | AND COMPRESSOR DO NOT SHOW LISTING. | | | PLEASE SUBMIT LISTING ON BOTH UNITS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2003-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-22 |
Time |
13:33 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2003-01-22 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2003-01-22 00:00:00 | SUBMITTAL OK - WATER BOOSTER PUMP - U.G. | | | SOIL PIPING - PIPE HANGERS - FLOOR SINKS | | | DOMESTIC WATER HEATERS - SOLENOID GAS | | | VALVE - |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-13 |
Time |
11:23 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2003-01-13 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | DENIED | | | REFERENCE: SPC-94-SGC-97-FACBC-97 | | | | | | 1) SHT P2-1.2 REVISION #6 NOT FOUND. | | | PLEASE INDICATE REVISION BY CLOUDING. | | | 2) SHT P2-2.6 10" PIPE UP TO OVERFLOW | | | DRAIN BEING ELIMINATED. PLEASE INDICATE | | | HOW AREA OF ROOF, (19,045 SQ FT), WILL | | | BE DRAINED IF PRIMARY DRAIN IS BLOCKED. | | | 3) ALL CHANGES FOR SANITARY, WATER, OR | | | STORM SYSTEMS SHALL BE SHOWN ON RISER | | | DIAGRAMS FOR EACH SYSTEM. PLEASE SUBMIT | | | CHANGES FOR RISER DIAGRAMS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2002-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-23 |
Time |
15:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-12-23 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2002-12-23 00:00:00 | SUBMITTALS FOR IRRIGATION - OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2002-12-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-12-03 |
Time |
09:52 |
Rev Time |
0.66 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-03 00:00:00 | SUBMITTALS FOR ID TAGS FOR PIPING, PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2002-11-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-09 |
Time |
14:42 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2002-11-09 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2002-11-09 00:00:00 | SUBMITTAL OK - LAUNDRY TRAY |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-29 |
Time |
15:31 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2002-10-29 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2002-10-29 00:00:00 | SUBMITTALS - PLMG FIXTURES - ANCHORS - | | | SUPPORTS - GREASE TRAP - GAS BOILER - | | | F.D. TRAP PRIMER - HEATER STAND - THREAD | | | ANCHORS - HOSE BIBB/WALL HYDRANT - NO | | | HUB COUPLINGS - SHOCK ABSORBER - CIRC. | | | PUMPS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-11-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-15 |
Time |
17:26 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2001-11-15 |
Time |
17:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-15 |
Time |
13:03 |
Rev Time |
8.00 |
| Received By |
kstevens |
Date |
2001-10-15 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2001-10-15 00:00:00 | DENIED | | | REFERENCE: SPC-94 - SGC-97 - FACBC-97 | | | | | | 1) GREASE TRAP, TYPE AND SIZE. CONTACT | | | WPB RSTP, ENVIRONMENTAL COMPLIANCE. R | | | COMPO (561) 837-4074 ORD #2938-96. | | | PLEASE PROVIDE SEATING CAPACITY, BALL- | | | ROOM HOLDS 3904. RESPONSE NOTED, BUT NOT | | | ADDRESSED FROM PREVIOUS REVIEW. | | | 2) SHTA1-7.1 - 7.2, PROVIDE CALCULATIONS | | | FOR PRIMARY AND SECONDARY STORM DRAINS. | | | SEC 1108 AND 1109 + 1/2 THE AREA OF THE | | | VERTICAL WALLS, UPPER ROOFS DRAINING TO | | | LOWER ROOFS TO BE INCLUDED. CALCULATIONS | | | ARE REQUIRED TO CHECK PIPE SIZES. | | | 3) SHT P1-1.1 AHU CONDENSATE DRAIN DE- | | | TAIL, COMPLY W/SEC 104.2 & 104.3 PLANS & | | | SPECS., PROVIDE AN ISOMETRIC DRAWING OF | | | A COMMON A/C CONDENSATE SYSTEM, CONNECT- | | | ED TO STORM DRAINAGE SYSTEM OUTSIDE OF | | | BUILDING WITH A OVERFLOW VENT 6" ABOVE | | | GRADE AS REQUESTED IN PREVIOUS REVIEW. | | | 4) SHT P2-1.1 CONDENSATE TIED INTO STORM | | | INSIDE BLDG AT INTERSECT. OF COLS B & 4 | | | VOL III. | | | 5) SHT P2-1.1 COMPLY W/SEC 714 MAXIMUM | | | FIXTURE LOAD ON THE DWV SYSTEM. SHOW | | | FIXTURE UNIT LOAD THROUGHOUT SYSTEM. SEC | | | 104.2 (TALK TO GEORGE HAZAU) | | | 6) SHT P2-1.3, CAN WASH & TRASH COMPACT- | | | OR, CONNECT TO GREASE WASTE. LOCAL ORD | | | #2938-96. STK DIAG. "H" SANT SHOWS CAN | | | WASH STILL ON SANT. SHT P3-2.3 | | | 7) SHT P3-2.2, STACK "D", "Q" PLBG. FIX- | | | TURES FROM UPPER FLOORS SHALL NOT DIS- | | | CHARGE INTO A BATTERY VENTED BRANCH. | | | SHOW UPPER FLOOR DISCHARGING INTO SEPAR- | | | ATE 4" LINE THAT FLOOR DRAINS ARE DRAIN- | | | ING INTO. | | | 8) SHTP3-2.1 THRU P3-2.4 STK DIAGRAMS. | | | STK "D" ISOMETRIC DOES NOT MATCH FLAT | | | DRAWING, FLOOR DRAIN BY D.F. ARE ALL FD | | | VENTS TYPICAL IN REST ROOMS? | | | 9) SHOP DRAWING SHALL BE PROVIDED FOR | | | THE U/G UTILITY SERVICE BOX FROM THE | | | MANUFACTURE TO SHOW HOW THERE IS NOT A | | | CROSS CONNECTION OF WASTE AND POTABLE | | | WATER SEC 601.5 AS REQUESTED IN PREVIOUS | | | REVIEW. | | | GAS PERMIT REQUIREMENTS | | | 10) GAS ISOMETRIC ON SHT P4-1.3 HEADER | | | IN KITCHEN TO BE UNIFORM. SHOWS 4" TO 3" | | | TO 2-1/2" THEN BACK TO 4". ALSO SEDIMENT | | | TRAP SHALL BE UPSTREAM OF EQUIPMENT NOT | | | AND END OF LINE AS SHOWN. | | | 11) CALCULATIONS FOR COMBUSTION AIR. | | | SHOW COMBUSTION AIR FOR BOILER AND CALCS | | | WATER HEATERS DIRECT VENT THRU ROOF NOT | | | SHOWN. | | | 12) INDICATE DELIVERY PRESSURE. FPU | | | DELIVERS 12" TO 14" WC - .5 PSI | | | 13) SUBMIT DETAIL SHOWING THE TYPE, SIZE | | | LOCATION, AND TERMINATION OF GAS VENTS. | | | | | | REVIEW BY PAUL SCHMITZ/KEN STEVENS | | | (561) 659-8096 EXT. 8233/8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-08-05 |
Time |
13:30 |
Rev Time |
18.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-05 00:00:00 | PLUMBING PLAN REVIEW, DENIED. | | | CODE REFEREMCES,SBC-97,SGC-97 SPC-94 | | | FL ACCESSIBILIY CODE REVISED-98 | | | VOLUME (I) | | | (1) FOOD SERVICE ESTABLISHMENTS,REQUIRE | | | PLAN REVIEW/WITH COMMENTS PRIOR TO PLBG | | | PLAN REVIEW,CONTACT DEPARTMENT OF HOTEL | | | BUSINESS REGULATION, 954-958-5520. | | | (2) GREASE TRAP,TYPE AND SIZE. CONTACT | | | W PALM BCH RSTP,ENVIROMENTAL COMPLIANCE. | | | RODNEY COMPO 561-837-4074 ORD# 2938-96. | | | (3) SHT A1-7.1-7.2, PROVIDE CALCULATIONS | | | FOR THE PRIMARY & SECONDARY STORM DRAINS | | | SEC 1108.1,2,3,4,5,ONE HALF THE AREA OF | | | VERTICAL WALLS, UPPER ROOFS DRAINING TO | | | LOWER ROOFS, TO BE INCLUDED. | | | (4) SHT A5-8.3 DETAIL #20, H/C,W/C FLUSH | | | HANDLES TO COMPLY W/SEC 4.16.5, SHALL | | | BE ON THE MOUNTING SIDE OF FIXTURE. | | | (5)SHT D1-0.0,2.1 FINISH LEGEND,UNGLAZED | | | FLOOR TILE, T-2,T-4,T-5,COMPLY W/SBC-97 | | | 1204.2,NON ABSORBENT FLOOR SURFACE. | | | VOLUME (II) | | | (6) SHT INDEX: MINIMUM FACILITIES, SHOW | | | NUMBER OF DRINKING FOUNTAINS,USE,TAB 407 | | | AND FACBC-98 REV,SEC 4.1.3 (A)(B). | | | VOLUME (III) & (IV) | | | (7) SHT P4-1.1 AHU CONDENSATE DRAIN DE- | | | TAIL, COMPLY W/SEC 104.3 PLANS & SPEC'S, | | | PROVIDE A ISOMETRIC DRAWING OF A COMMON | | | A/C CONDENSATE SYSTEM,CONNECTED TO STORM | | | DRAINAGE SYSTEM OUTSIDE OF BUILDING WITH | | | A RELIEF VENT 6" ABOVE GRADE. | | | (8) SHT P1-1.1, WATER HAMMER ARRETORS,TO | | | BE INSTALLED AS PER MFG. INSTALLATION | | | INSTRUCTIONS FOR SIZE AND PLACEMENT. | | | SEC 607.8.2, INSTALLED AS PER PDI-WH201 | | | (9) SHT P2-1.1 COMPLY W/SEC 714 MAXIMUM | | | FIXTURE LOAD ON THE DWV SYSTEM. SHOW | | | FIXTURE UNIT LOAD THRU OUT SYSTEM. | | | (10) SHT P4-2.2,2.4, CAN WASH AND TRASH | | | COMPACTOR, CONNECT TO GREASE WASTE. | | | LOCAL ORDINANCE # 2938-96. | | | (11) SHT P4-2.1,2.3, STACK "D","Q", | | | PLBG FIXTURES FROM UPPER FLOORS, SHALL | | | NOT DISCHARGE INTO A BATTERY VENTED | | | BRANCH SPC-95 SEC 914.1 | | | (12) SHT P4-1.1 EWH DETAIL,TO BE READILY | | | ACCESSIBLE,SEC 501.7, PROVIDE A DETAIL | | | OF A WORKING PLATFORM W/ A SHIPS LADDER, | | | OR SET THE DWH THE ON FLOOR. | | | SEC 507.8.2, MIN.SIZE PAN DRAIN, 1". | | | DWH DRAINS,SEC 802,ALL I/D WASTE TO F/S. | | | (13) SHT P3-1.5 ALCOVE DWV SYSTEM DESIGN | | | COMLPY WITH 921.1, COMBINATION WASTE AND | | | VENT SYSTEM. THIS SHOULD BE TYPICAL FOR | | | CONSESSION AND FOODN SERVICE SYSTEMS. | | | (14) SHT P4-2.1 THRU 2.4,STACK DIAGRAMS. | | | CIRCUIT AND LOOP, BRANCH SOIL OR WASTE | | | PIPE SHALL BE UNIFORM THROUGH ITS ENTIRE | | | LENGTH. SEC 914.1 | | | (15A) SHT P2-1.1 TO 1.8, EXHIBIT HALL | | | U/G DWV SYSTEM PIPING,TO COMPLY WITH SEC | | | 921, COMBINATION WASTE AND VENT SYSTEM. | | | ONE VENT UPSTREAM, BETWEEN THE LAST TWO | | | FIXTURE DRAINS, ONE VENT DOWN STREAM, | | | BEFORE THE FIRST FIXTURE DRAIN. | | | SEE ILLUSTRATION APPEX "J" PG.275,ALSO | | | SEE DIFINITIONS CH-2 FIXTURE DRAIN AND | | | FIXTURE BRANCH. | | | (15B) PROVIDE SHOP DRAWINGS FOR THE U/G | | | UTILITY SERVICE BOX,FROM THE MANUFACTURE | | | TO SHOW HOW THERE IS NOT A CROSS CONNECT | | | ION OF WASTE AND POTABLE WATER,SEC 601.5 | | | (16)SHT P2-1.1 THRU 4.1, SEC 104.3 PLANS | | | PROVIDE ISOMETRIC DRAWINGS OF THE WATER | | | PIPING SYSTEM, WITH CALCULATIONS FOR THE | | | DISCHARGE FIXTURE UNIT DEMAND. | | | NO MORE THAN TWO FIXTURES 0N 1/2" C/W. | | | NO MORE THAN FOUR FIXTURES ON 1/2" H/W. | | | MODEL CNTY WIDE AMENDMENTS, SPC-94,607.7 | | | | | | GAS PERMITREQUIRMENTS | | | CODE REFERENCES SGC-97,NFPA-54 | | | (17A) SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE, | | | CORRESPONDING LENGTHS AND PIPE SIZES. | | | (B) TYPE OF PIPING MATERIAL, ALL PIPE | | | SIZES, TYPE OF GAS, BTU LOAD OF EACH | | | APPLIANCE AND TOTAL BTU LOAD ON SYSTEM. | | | (C) SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY,TO THE MOST REMOTE OUTLET IN | | | THE BUILDING. (TOTAL DEVELOPED LGTH) | | | (D) CALCULATIONS FOR COMBUSTION AIR | | | (E) INDICATE DELIVERY PSI, (2# OR .5#). | | | (F) SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE, TERMINATION OF GAS VENTS | | | (G) SUBMIT MANUFACTURE SHEETS FOR ALL | | | GAS EQUIPMENT,TO VERIFY COMPLIANCE WITH | | | LOCAL CODES. | | | (H) SHOW LOCATION OF GAS METER. | | | (I) SPECIFY, SIZE & TYPE OF REGULATORS. | | | REQUIRED FOR THIS SYSTEM. | | | END OF COMMENTSPAUL SCHMITZ | | | QUESTIONS561-659-8096 X 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-20 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-20 |
Time |
11:25 |
Sent To |
I |
|
| Notes |
| 2004-05-20 00:00:00 | ERIC SCHNEIDER, SENIOR PLANNER ONLY | | | APPROVING, FIELD BULLETIN 44, FIELD | | | BULLENTIN 52A AND LANDSCAPE SHEET L-5. | | | NEEDS FIRE & ENG TO REVIEW MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-01-08 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-01-08 |
Time |
15:50 |
Sent To |
I |
|
| Notes |
| 2004-01-08 00:00:00 | ERIC SCHNEIDER SENIOR PLANNER APPROVED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-07-17 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | APPROVED BY ESCHINEIDER, WESTERN MOST | | | TREE MUST BE PLANTED WHERE BUFFER BEGINS | | | TO WIDEN TO FIVE FEET |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-12-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
17:33 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-13 00:00:00 | | | | "PROVISO" | | | ------- | | | | | | SHEET A1-1.4 PORTION 4 -- SW FIRE | | | DEPARTMENT ACCESS TO BE PERMITTED UNDER | | | SEPERATE PERMIT. NOT APPROVED AS PART | | | OF THIS PERMIT-ERIC SCHNEIDER 659-8031 |
|
|