Plan Review Details - Permit 01071382
Plan Review Stops For Permit 01071382
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-05-16 Cont ID  
Sent By jwitmer Date 2002-05-16 Time 07:50 Rev Time 0.15
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-16 00:00:00TYPE II BLD 2ND FLOOR INTERIOR MOUNT,
 1ST FL EXTERIOR MOUNT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 11:40 Rev Time 1.25
Received By jwitmer Date 2002-01-10 Time 11:40 Sent To  
Notes
2002-01-10 00:00:00MASTER 01071385
 MODEL TYPE: II
 BUILDING PROVISO:
 NO SURVEY WITH PLAN, TABLE 600 ISSUES
 CAN NOT BE ADRESSED (WINDOW OPENINGS VS
 PROPERTY LINE. THIS CONCERN WILL BE
 ADDRESSED ONA INDIVIDUAL BASIS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-28 Cont ID  
Sent By jwitmer Date 2001-11-28 Time 18:25 Rev Time 0.50
Received By jwitmer Date 2001-11-28 Time 18:25 Sent To  
Notes
2001-11-28 00:00:00BUILDING PLAN REVIEW
 PLAN REVIEW 01071382
 TYPE II MODEL "GGDDGG"
 CONT: TRANSEASTERN
 TEL: 753-5531
  
  
 SEE NOTES PLAN REVIEW:01071374

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 21:08 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 21:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By dpalmer Date 2001-08-21 Time 08:49 Rev Time 0.00
Received By dpalmer Date 2001-08-21 Time 08:49 Sent To  
Notes
2001-08-21 00:00:00****************** UNSAT *************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-11-19 Cont ID  
Sent By mcarsill Date 2001-11-19 Time 11:51 Rev Time 0.00
Received By mcarsill Date 2001-11-19 Time 11:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-10-04 Cont ID  
Sent By mcarsill Date 2001-10-04 Time 15:24 Rev Time 0.00
Received By mcarsill Date 2001-10-04 Time 15:24 Sent To  
Notes
2001-10-04 00:00:00PREVIOUS PLAN REVIEW COMMENTS NOT
 FULLY ADDRESSED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By mcarsill Date 2001-08-07 Time 14:23 Rev Time 0.00
Received By mcarsill Date 2001-08-07 Time 14:23 Sent To  
Notes
2001-08-07 00:00:001) NO SITE PLAN INDICATING WHERE
 BUILDING WILL BE BUILT.
 2) NO FIRE HYDRANT LOCATION MAP. WET
 FIRE HYDRANTS ARE REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 3) BUILDING ADDRESSES REQUIRED.
 4) ARE THESE BUILDINGS RENTALS OR
 OWNED.
 5) TENANT SEPARATIONS TO COMPLY WITH
 BUILDING CODE REQUIREMENTS.
 6) ELECTRIC POWERED SMOKE DETECTORS
 ARE REQUIRED. WHEN ACTIVATED, THESE
 DEVICES ARE TO BE AUDIBLE IN THE
 SLEEPING ROOMS OF THAT UNIT.
 7) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
 8) STORAGE NOT PERMITTED UNDER STAIRS
 UNLESS PROPERLY FIRE RATED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096, EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-12-04 Cont ID  
Sent By pkrauss Date 2001-12-04 Time 15:42 Rev Time 2.00
Received By pkrauss Date 2001-12-04 Time 15:42 Sent To Z
Notes
2001-12-04 00:00:00*******************PROVISO**************
  
  
 EXHAUST DUCT FOR DRYER SHALL NOT EXCEED
 25'.THERE SHALL BE A DEDUCTION OF 2
 1/2'FOR EACH 45 DEGREE BEND AND 5' FOR
 EACH 90 DEGREE BEND.THE WALL OR ROOF
 CAP SHALLBE NONSCREENED WITH BACK
 DRAFT DAMPER.
  
 PLEASE INDICATE HOW COMBUSTIBLE LINT
 WILL BE REMOVED (CLEANOUTS).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 10:07 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2001-10-13 00:00:001ST RESUB NO MECH PLANS SUBMITTED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 10:06 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2001-10-13 00:00:00FAILED AS PER NANCY DENMARK 8-23-01.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-01-11 Cont ID  
Sent By kstevens Date 2002-01-11 Time 17:38 Rev Time 0.50
Received By kstevens Date 2002-01-11 Time 17:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-11-21 Cont ID  
Sent By kstevens Date 2001-11-21 Time 21:10 Rev Time 0.50
Received By kstevens Date 2001-11-21 Time 21:09 Sent To  
Notes
2001-11-21 00:00:00DENIED
  
 1) PAGES A-3/A-10 "D" UNITS LAVS ARE BE-
 TWEEN W/C AND SHOWER ON FLOOR PLAN AND
 ARE LEFT OF W/C ON RISER DIAGRAM. ALSO
 RISER DIAGRAM ONLY SHOWS ONE LAV AND TWO
 ARE SHOWN ON FLOOR PLAN. PLEASE CLARIFY
  
 2) THIRD NOTICE: APPROVED UTILITY PLAN
 REQUIRED FOR FINAL PLUMBING PLAN REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-10-29 Cont ID  
Sent By kstevens Date 2001-10-29 Time 11:14 Rev Time 0.50
Received By kstevens Date 2001-10-29 Time 11:14 Sent To  
Notes
2001-10-29 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) APPROVED UTILTTY PLANS ARE REQUIRED
 FOR FINAL PLUMBING PLAN REVIEW OF BUILD-
 INGS.
  
 2) PAGES A-3/A-11 "G" UNITS. 2ND FLOOR
 SANT. RISER DOES NOT REFLECT FLOOR PLAN.
 TUB BATH LAV ON RIGHT HAND SIDE OF W/C.
 M/B ONLY 1 LAV, (2 SHOWN), & SHR ON R-
 SIDE OF W/C.
  
 3) PAGES A-3/A-10 "D" UNITS. RISER DIA-
 GRAM - LAVS AND SHOWER ON LEFT SIDE OF
 W/C IN M/BATH DOES NOT REFLECT FLOOR
 PLAN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-16 Cont ID  
Sent By jleech Date 2001-08-16 Time 17:20 Rev Time 0.00
Received By jleech Date 2001-08-16 Time 17:20 Sent To  
Notes
2001-08-16 00:00:00SEE PLAN REVIEW NOTES UNDER 01071374

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-01-22 Cont ID  
Sent By hpiskura Date 2001-08-27 Time 11:30 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-08-27 00:00:00SEE NOTES ON 01071374

Review Stop Z ZONING
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By drunnels Date 2002-01-22 Time 11:11 Rev Time 0.25
Received By drunnels Date 2002-01-22 Time 11:11 Sent To  
Notes
2002-01-22 00:00:00SITE PLAN APPROVED PER MIKE SANCHEZ 01/1
 22/02 DR

Review Stop Z ZONING
Rev No 1 Status F Date 2001-12-10 Cont ID  
Sent By pkrauss Date 2001-12-05 Time 10:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-12-10 00:00:00NO APPROVED SITE PLAN