Plan Review Details - Permit 01071374
Plan Review Stops For Permit 01071374
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-05-16 Cont ID  
Sent By jwitmer Date 2002-05-16 Time 07:41 Rev Time 0.15
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-16 00:00:00STORM SHUTTERS 2ND FL INTERIOR MOUNT,
 1ST FL EXTERIOR MOUNT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 12:17 Rev Time 1.25
Received By jwitmer Date 2002-01-09 Time 18:28 Sent To  
Notes
2002-01-10 00:00:00BUILDING TYPE I (MODEL)
 MASTER 01071374
 BUILDING PROVISO:
 NO SURVEY WITH PLANS, TABLE 600 ISSUES
 CAN NOT BE ADDRESSED (WINDOW OPENINGS VS
 PROPERTY LINE). THIS CONCERN WILL BE
 ADDRESSED ON A INDIVIDUAL PERMIT BASIS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-28 Cont ID  
Sent By jwitmer Date 2001-11-28 Time 17:40 Rev Time 1.75
Received By jwitmer Date 2001-11-28 Time 16:41 Sent To  
Notes
2001-11-28 00:00:00BUILDING PLAN REVIEW
 PLAN REVIEW 01071374
 TYPE I MODEL "BBAABB"
 CONT: TRANSEASTERN
 TEL: 753-5531
  
 SBC=1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 PLANS SUBMITTED FOR PERMIT APPLICATION
 AFTER JAN.1,2002 WILL BE REVIEWED UNDER
 2001 FLORIDA BUILDING CODE REGARDLESS
 OF A EARLIER PLAN REVIEW UNDER 1997 SBC.
  
 1)- PLANS CAN NOT BE REVIEWED FOR SBC
 TABLE 600 ISSUES-HORIZONTAL SEPERATION,
 UNTIL A PLOT PLAN OR SURVEY IS SUBMITTED
  
 2)- NORANDEX WINDOWS REQUIRES SITE SPEC-
 IFIC REPORT. ACHETECT MUST SIGN, SEAL&
 DATE EACH REPORT.
 3)- SHEET C-1 NOTE #14, HI RIB LATH.
 ASTM C 1063 7.10.1.1.HIRIB TO BE FASTEN-
 ED AT EVERY RIB (4" O.C.)
 4)- PLANS ARE TO BE SUBMITTED TO THE
 COUNTY FOR REVIEW OF IMPACT FEES.
 5)- EACH LOT (TOWNHOUSE) SHALL SUBMIT
 FOR A PERMIT APPLICATION WITH ASSOCIATED
 FEES.
 6)- THIS PROJECT MAY REQUIRE A RESIDENT
 INSPECTOR. CONTACT DON NEELY AT 659-8096
 EX.8333 FOR MORE INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096X8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-06-18 Cont ID  
Sent By btrobaug Date 2002-06-06 Time 11:02 Rev Time 0.00
Received By dpalmer Date 2002-06-06 Time 10:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 20:57 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 20:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By dpalmer Date 2001-08-21 Time 08:23 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 22:36 Sent To  
Notes
2001-08-21 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 PLEASE NOTE THAT PLANS NEED RATINGS
 FOR MAIN BRKR/LOAD CENTER.
  
 2)NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELELCTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-11-19 Cont ID  
Sent By mcarsill Date 2001-11-19 Time 12:01 Rev Time 0.00
Received By mcarsill Date 2001-11-19 Time 12:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-10-04 Cont ID  
Sent By mcarsill Date 2001-10-04 Time 16:53 Rev Time 0.00
Received By mcarsill Date 2001-10-04 Time 16:53 Sent To  
Notes
2001-10-04 00:00:00NOT ALL PREVIOUS PLAN REVIEW COMMENTS
 ADDRESSED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By mcarsill Date 2001-08-07 Time 14:16 Rev Time 0.00
Received By mcarsill Date 2001-08-07 Time 14:16 Sent To  
Notes
2001-08-07 00:00:001) NO SITE PLAN INDICATING WHERE
 BUILDING WILL BE BUILT.
 2) NO FIRE HYDRANT LOCATION MAP. WET
 FIRE HYDRANTS ARE REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 3) BUILDING ADDRESSES REQUIRED.
 4) ARE THESE BUILDINGS RENTALS OR
 OWNED.
 5) TENANT SEPARATIONS TO COMPLY WITH
 BUILDING CODE REQUIREMENTS.
 6) ELECTRIC POWERED SMOKE DETECTORS
 ARE REQUIRED. WHEN ACTIVATED, THESE
 DEVICES ARE TO BE AUDIBLE IN THE
 SLEEPING ROOMS OF THAT UNIT.
 7) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
 8) STORAGE NOT PERMITTED UNDER STAIRS
 UNLESS PROPERLY FIRE RATED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-12-05 Cont ID  
Sent By pkrauss Date 2001-12-05 Time 09:26 Rev Time 2.00
Received By pkrauss Date 2001-12-05 Time 07:55 Sent To Z
Notes
2001-12-05 00:00:00*******************PROVISO**************
  
  
 EXHAUST DUCT FOR DRYER SHALL NOT EXCEED
 25'.THERE SHALL BE A DEDUCTIONS OF 2
 1/2' FOR EACH 45 DEGREE BEND AND 5' FOR
 EACH 90 DEGREE BEND.THE WALL OR ROOF
 CAP SHALL BE NONSCREENED WITH ADRAFT
 DRAFT DAMPER.
  
 PLEASE INDICATE HOW COMBUSTIBLE LINT
 WILL BE REMOVED (CLEANOUTS).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 09:49 Rev Time 0.40
Received By pkrauss Date 2001-10-13 Time 09:41 Sent To  
Notes
2001-10-13 00:00:00*******************DENIED***************
  
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.
  
 1.PROVIDE EQUIPMENT INFORMATION.
  
 2.ENERGY CALCULATIONS WITH MANUAL J
 CALCS FOR EQUIPMENT SIZING.
  
 3.INFORMATION ON BATHROOM EXHAUST
 FANS.
  
 4.DUCT MATERIAL, R-VALUE, SIZE, CFM
 DISTRIBUTION AND GRILL SIZE.
  
 5.INDICATE DRYER EXHAUST DUCT SIZE,
 MATERIAL AND TERMINATION.
  
 6.INDICATE LOCATION OF CONDENSER
 UNITS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-23 Cont ID  
Sent By ndenmark Date 2001-08-23 Time 08:51 Rev Time 0.33
Received By ndenmark Date 2001-08-23 Time 08:51 Sent To  
Notes
2001-08-23 00:00:00DENIED
 1.PLANS LACK INFORMATION ON MECHANICAL
 SYSTEMS, INCLUDING CODE REQUIRED MINIMUM
 VENTILATION AND EXHAUST FOR BATHROOMS.
 2. PROVIDE INFORMATION ON BATHROOM
 EXHAUST, DRYER EXHAUST AND AIR
 CONDITIONING SYSTEM TO BE INSTALLED FOR
 REVIEW.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-01-11 Cont ID  
Sent By kstevens Date 2002-01-11 Time 17:34 Rev Time 0.50
Received By kstevens Date 2002-01-11 Time 17:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-11-21 Cont ID  
Sent By kstevens Date 2001-11-21 Time 21:14 Rev Time 0.50
Received By kstevens Date 2001-11-21 Time 21:14 Sent To  
Notes
2001-11-21 00:00:00DENIED
  
 THIRD NOTICE: APPROVED UTILITY PLAN RE-
 QUIRED FOR FINAL PLUMBING PLAN REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-10-29 Cont ID  
Sent By kstevens Date 2001-10-29 Time 11:10 Rev Time 0.50
Received By kstevens Date 2001-10-29 Time 11:10 Sent To  
Notes
2001-10-29 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) APPROVED UTILITY PLANS ARE REQUIRED
 FOR FINAL PLUMBING PLAN REVIEW OF BUILD-
 INGS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-16 Cont ID  
Sent By jleech Date 2001-08-16 Time 17:09 Rev Time 4.00
Received By jleech Date 2001-08-16 Time 17:09 Sent To  
Notes
2001-08-16 00:00:00DENIED;
 1."B" UNIT RISER DIAGRAM. 2" WET VENT
 CAN HAVE A MAXIMUM OF 4 FIXTURE UNITS.
 VENT FOR WATER CLOSET WITH LAV, TUB,
 AND SHOWER MUST BE 3" AFTER SHOWER TO
 PROPERLY VENT W/C SPC SEC. 911.1.
 2.APPROVED UTILITYS PLANS ARE REQUIRED
 FOR FINAL PLUMBING PLAN REVIEW OF BUILD-
 INGS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8369

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By hpiskura Date 2001-10-26 Time 09:32 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-10-26 00:00:00SHEET C1, FRAMING NOTES.THE ARCHITECTS
 DISCLAIMER FOR STRUCTURAL
 RESPONSIBILITY IS NOT ACCEPTABLE.IN
 DELEGATING ENGINEERING RESPONSIBILITY
 TO A SPECIALTY ENGINEER IT IS THE
 DESIGNER OF RECORD'S DUTYTO NOTE THE
 LOCATION, NATURE, MAGNITUDE AND
 DIRECTION OF LOADS TO BE RESISTED.AT
 TIME OF PERMIT APPLICATION PROVIDE
 SIGNED AND SEALED CALCULATIONS
 DEMONSTRATING COMPLIANCE WITH SBC 1601.
  
 IN THE ABSENCE OF A SURVEY AND SITE
 PLANA COMPLETE REVIEW FOR CODE
 COMPLIANCE IS NOT POSSIBLE.
  
 SHEET A10 OF THE TYPE 3 BUILDING. TERMS
 LIKE "(STRINGER BEARING TO COMPLY W/ SBC
 1997)" ARE NOT ACCEPTABLE SUBSTITUTES
 FOR SPECIFIC DESIGN INFORMATION.SEE
 SBC104.2.SAME SHEET, THE REFERENCE
 SFBC 2907.3 (C) IS WITHOUTSTANDING.
  
 WITH REGARDS TO FREE AREA OF A SOFFIT
 SCREEN VENT, A 7" X 22" SCREEN CAN
 PROVIDE 40% TO 60% OF FREE AREA AND NOT
 THE SIZE OF THE ROUGH OPENING.
 FURTHER, WHEN INSTALLED SUBSEQUENT TO
 WIRE LATH ADDITIONAL AREA REDUCTION
 MUST BE ALLOWED FOR.
  
 SEE THE 8/27/01 LIST FOR IMPACT FEES,
 RESIDENT INSPECTOR, ETC.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-01-22 Cont ID  
Sent By hpiskura Date 2001-08-27 Time 07:47 Rev Time 0.00
Received By hpiskura Date 2001-08-23 Time 16:21 Sent To  
Notes
2001-08-27 00:00:00SHEET C1 SHOULD CITE THE 1997 SBC AS
 THEGOVERNING DESIGN CODE AND NOT " ...
 AS APPLICABLE ..."
  
 THERE WAS NO SITE PLAN OR SURVEY
 INCLUDED WITH THE PLANS SO A COMPLETE
 REVIEW FOR CODE COMPLIANCE WAS NOT
 POSSIBLE.
  
 SOIL TREATMENT REQUIREMENTS SHOULD BE
 ADDED TO THE FOUNDATION NOTES.SEE SBC
 2304.1.2 AS AMENDED.
  
 PLANS SUBMITTED FOR PUBLIC RECORD ARE
 REQUIRED TO BE SIGNED, SEALED AND DATED
 BY THE DESIGNER OF RECORD.SEE FS 471
 AND 481.
  
 SHEET C1 FRAMING NOTES, NOTE 6."THE
 ARCHITECT ACCEPTS NO RESPONSIBILITY FOR
 STRUCTURAL ..." A REGISTERED DESIGN
 PROFESSIONAL MUST ASSUME RESPONSIBILITY
 FOR THE STRUCTURAL REQUIREMENTS.
  
 SHEET C1 THE LOAD SCHEDULE IS NOT CLEAR
 AS TO WHETHER ASCE 7 OR 1606.2 WAS USED
 FOR THE WIND DESIGN.
  
 PROVIDE ENERGY CODE CALCULATIONS WITH
 THE PERMIT APPLICATION.
  
 PROVIDE A TEST REPORT OR NOTICE OF
 ACCEPTANCE FOR THE ROOF COVERING WITH
 THE PERMIT APPLICATION.
  
 SHEET A2, PROVIDE THE SUPPORTING
 DOCUMENTATION FOR THE "SAFE LOAD TABLE"
  
 SHEET A2. NOTE THE REQUIREMENT FOR
 SAFETY GLASS IN ACCORDANCE WITH SBC
 2405.2 #3 FOR THE GLAZING IN THE
 VICINITY OF THE ENTRANCE DOORS.A
 GENERIC NOTE ON THE COVER SHEET IS
 INSUFFICIENT.
  
 SHOW A CONSTRUCTION DETAIL FOR THE AREA
 SHOWN AS "FRAMED DOWNED" ON SHEET A4.
  
 SHEET A9.SHOW THE STAIR STRINGER AND
 TREAD SIZE AND MATERIAL SPECIFICATION.
  
 SHEET A9, STAIR DETAIL, HAS CONFLICTING
 INFORMATION FOR THE PICKET SPACING (4 -
 6) AND FASTENER SIZE (#12 SCREW AND 5/8"
 SCREW)PLEASE REVISE AS NECESSARY.
  
 PLEASE EXPLAIN HOW THE DETAIL SHOWN AS
 "OPTION 1" ON SHEET A9 WILL ADEQUATELY
 ADDRESS GRAVITY LOADS.
  
 THE DETAIL ON SHEET A10 CALLS FOR FRT
 SHEATHING FROM A CENTERLINE WHILE SBC
 704.4.1 #2 REQUIRES FRT TO 4' FROM
 EITHER SIDE OF THE WALL.REVISE AS
 NECESSARY.
  
 PLEASE SPECIFY THE FREE AREA OF THE 6" X
 24" SOFFIT VENTS TO BE USED SO THAT
 COMPLIANCE WITH SBC 2309.7 MAY BE
 DETERMINED.
  
 SHOW A DETAIL FOR THE WINDOW AND DOOR
 BUCK CONNECTIONS.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO THE
 COUNTY AND THE PERMIT PLANS STAMPED BY
 THEM.CALL 233-5025 FOR MORE
 INFORMATION.
  
 A SEPARATE PERMIT APPLICATION IS
 REQUIRED FOR EACH TOWNHOUSE UNIT.
  
 ON BUILDING TYPE 3, UNITS LABELED E MUST
 COMPLY WITH SBC 1010.4.
  
 A RESIDENT INSPECTOR MAY BE REQUIRED FOR
 THIS PROJECT.CONTACT DON NEELY AT
 659-8093 X 8333 FOR MORE INFORMATION.

Review Stop Z ZONING
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By drunnels Date 2002-01-22 Time 14:16 Rev Time 0.25
Received By drunnels Date   Time   Sent To  
Notes
2002-01-22 00:00:00SITE PLANS APPROVED 01/22/02 MIKE SANCHE
 Z DR

Review Stop Z ZONING
Rev No 1 Status N Date 2002-01-22 Cont ID  
Sent By pkrauss Date 2001-12-05 Time 10:12 Rev Time 0.25
Received By jwitmer Date   Time   Sent To  
Notes
2001-12-10 00:00:00NO APPROVED SITE PLAN