| Plan Review Stops For Permit 01071328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-03-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-03-21 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-21 00:00:00 | 2ND SET OF SUBMITTALSOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-10-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-09 |
Time |
16:35 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-09 00:00:00 | BUILDINGPROVISO: COUNTY IMPACT FEES TO | | | BE PAIDED | | | STATE RADON REQUIRES PAYMENT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-26 |
Time |
06:53 |
Rev Time |
5.00 |
| Received By |
jwitmer |
Date |
2001-09-26 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2001-09-26 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01071328 | | | 2801 OKEECHOBEE BLVD. | | | TEL: (954) 781 2120 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS TO 1997 STANDARD BUILD- | | | ING CODE | | | FL ACCES CODE= FLORIDA ACCESSIBILITY | | | CODE 1997 EDITION | | | | | | 1)- A COMMENT FROM PREVIOUS PLAN REVIEW | | | IS ABOUT THE "OMEGALITE PANELS" REGARD- | | | ING FIRE RATING IN A FIRE DISTRICT, WHAT | | | IS NOT CLEAR ON SHEET S-6 DETAILS 4&5 | | | THE COMPOSITE SHEET IS MADE OF? THE DE- | | | TAILS SHOW THAT IT HAS A PLYWOOD BACKING | | | WE ARE TAKING THAT THIS IS NOT PART OF | | | THE COMPOSITE PANEL BUT A BACKING MATER- | | | IAL TO ATTACH THE PANELS TO. SBC FI02.1 | | | & F102.7 ARE FOR ARCHITECTURAL TRIM LOCA | | | TED IN A FIRE DISTRICT,NONCOMBUSTIBLE OR | | | FIRE RETARDANT TREATED PLYWOOD. | | | | | | 2)-THE TEST THAT ARE INDICATED ARE FOR | | | INTERIOR FLAME SPREAD AND SMOKE DEVELOP- | | | MENT, BY DEFINITION NONCOMBUSTIBLE CAN | | | BE TESTED (2) DIFFERENT WAYS,DEPENDING | | | ON THE THICKNESS OF THE MATERIAL THERE | | | HAS BEEN NO SPECS ON THIS MATERIAL AS TO | | | THICKNESS NOR THE FASTENING OF THE | | | SYSTEM TO WHATEVER MATERIAL THAT WILL BE | | | SUPPORTING THE COMPOSITE PANELS.THE 2 | | | METHOSOF TESTING ARE ASTM E 136 & | | | ASTM E 84 WHEN THE MATERIALS HAVING A | | | STRUCTURAL BASE OF NONCOMBUSTIBLE | | | MATERIALS AS DEFINED IN 1, WITH A SURFAC | | | ING NOT MORE THAN 1/8" THICK AND A | | | FLAMESPREAD RATING OF NOT MORE THAN 50 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E 84 | | | | | | 3)-MISSING ARE PRODUCT APPROVAL REPORTS | | | FOR THE OVERHEAD GARAGE DOORS, THE EXTER | | | IOR DOOR 2ND FLOOR, AND THE ROOFING | | | REPORT. THE CITY ACCEPTS SBCCI TESTING | | | REPORTS & DADE COUNTY, (2) COPIES OF | | | EACH REPORT.SBC 1606.2.6.2 | | | | | | 4)- S-6 DETAILS 4 & 5 WHAT IS THE MINI- | | | MUM WORKING DEPTH FOR TAPCONS IN THE 2X8 | | | PT FOR CONCRETE? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-08-13 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2001-08-08 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2001-08-13 00:00:00 | PLEASE PROVIDE A DIMENSIONED SITE PLAN | | | SO THAT COMPLIANCE WITH SBC TABLE 600 | | | MAY BE DETERMINED. | | | | | | CLEARLY SHOW THE MIXED OCCUPANCY | | | SEPARATIONS FOR THE B, M, AND S (REPAIR | | | GARAGE)SEE SBC 411.5, SBC 704.1. | | | | | | HOW WILL HANDICAP ACCESS TO THE LOUNGE | | | FROM THE SHOWROOM BE ACCOMPLISHED?SEE | | | FACBC 4.1.1. | | | | | | THERE ARE NO ROOF OVERFLOW SCUPPERS | | | SHOWN FOR THE SERVICE / RECEPTION | | | CANOPY.SEE SBC 1517.6.4.3. | | | | | | THE AREA SHOWN AS A "MEZZANINE" DOES NOT | | | MEET THE CRITERIA OF SBC 503.2.3 AND | | | THEREFORE MUST COMPLY WITH STORY | | | REQUIREMENTS, AS TO EGRESS AND FIRE | | | RATED SEPARATIONS.ALSO, SEE SBC | | | F102.2.5 FOR FIRE RESISTANT | | | CONSTRUCTION REQUIREMENTS FOR BUILDINGS | | | LOCATED INSIDE THE DESIGNATED FIRE | | | DISTRICT. | | | | | | PLEASE PROVIDE TEST DATA THAT THE | | | "OMEGALITE PANELS" ARE LISTED AS | | | NON-COMBUSTIBLE OR FIRE RETARDANT.SEE | | | SBC F102.1 AND F102.7 | | | | | | PROVIDE SPECIFIC STRUCTURAL CONNECTION | | | DETAILS FOR THE PANELS. | | | | | | THE STORE FRONT PRODUCT ACCEPTANCE | | | REPORTS PROVIDED ARE EXPIRED AND HAVE | | | SOME ILLEGIBLE PAGES. | | | | | | IMPACT FEES MUST BE PAID TO THE COUNTY | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED.CALL 561-233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-09-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-28 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-28 |
Time |
07:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-08 |
Time |
21:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-08 |
Time |
21:56 |
Sent To |
|
|
| Notes |
| 2001-08-08 00:00:00 | **************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE MISSING OUTLETS FOR | | | SHOW ROOM WINDOWS PER 210-62 | | | | | | 20NOTE: PLEASE NOTE THAT OANS ARE SHOW- | | | -ING THE SAME WIRE COUNT FROM GUTTER TO | | | MAINS AND FROM MAINS TO PANELS. PLEASE | | | NOTE THAT WIRE SCHEDULE IS SHOWING AN | | | EQUIPMENT GROUNDING CONDUCTOR FROM | | | GUTTER TO FIRST MEANS OS DISCONNECT. | | | THIS MEANS THE GROUND WOULD BE PARALLEL- | | | ING THE NEUTRAL. NOT PERMITTED PER 250 | | | OF NEC. | | | | | | 3)NOTE: PLEASE CLARIFY THAT MAIN 2 OF 5 | | | SHOWN AS 200AMPS W/ 4/0 CONDUCTORS AND | | | MAIN 4 OF 5 SHOWN AS 200AMPS ALSO BUT | | | WITH 3/0`S? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | NOTES 1&2 FOR REVIEW. NOTE 3 WAS JUST | | | FOR CLARIFICATION. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-08-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-08-15 |
Time |
09:24 |
Rev Time |
3.00 |
| Received By |
mamini |
Date |
2001-08-15 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2001-08-15 00:00:00 | PASSED : | | | 1. ANY NEW CONNECTIONS TO THE CITY'S | | | SERVICES WILL REQUIRE A SEPARATE PERMIT | | | FROM PUBLIC UTILITIES ENGINEERING | | | SERVICES DEPARTMENT,659-8040. | | | 2. ANY WORK WITHIN PUBLIC R.O.W WILL | | | REQUIRE A SEPARATE PERMIT FROM THE CITY | | | ENGINEER'S OFFICE,659-8040. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-09-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-27 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-27 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-02 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-02 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | 1) GATES ARE TO BE 20 FEET IN CLEAR | | | WIDTH WHEN OPENED. WHAT PROVISIONS | | | HAVE BEEN MADE FOR FIRE AND PARAMEDICAL | | | ACCESS INTO THE COMPLEX. | | | 2) BUILDING ADDRESS TO COMPLY WITH | | | CITY CODE 3343-00. | | | 3) PROVIDE OCCUPANT LOAD CALCULATIONS | | | AND A LIFE SAFETY PLAN TO THIS OFFICE. | | | 4) NO INTERIOR FINISH CLASSIFICATION | | | INFORMATION FOR WALLS AND CEILINGS | | | PROVIDED WITH PLANS. | | | 5) HOW WILL VEHICLES BE DISPLAYED IN | | | SHOWROOM. WHAT SAFETY PRECAUTIONS ARE | | | PLANNED. | | | 6) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE ALARM SYSTEM INSTALLATION. | | | 7) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE SPRINKLER SYSTEM INSTALLATION. | | | 8) SERVICE CANOPY TO BE AT LEAST | | | 13"- 6" HIGH. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-12 |
Time |
16:22 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-06-12 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2002-06-12 00:00:00 | TEST & BALANCE REPORT SUBMITTAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-03-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-13 |
Time |
12:53 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-03-13 |
Time |
12:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-14 |
Time |
13:00 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-08-14 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2001-08-14 00:00:00 | PROVISO: | | | SEPARATE PERMITS ARE REQUIRED FOR FUEL, | | | INCLUDING OIL AND USED OIL STORAGE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2002-05-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-14 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-14 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2002-05-14 00:00:00 | DENIED | | | | | | CHANGES ON A SIGNED AND SEALED SHALL BE | | | INITIALED AND DATED BY ENGINEER/ARCHITEC | | | T OF RECORD | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-05 |
Time |
16:00 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-05 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2001-10-05 00:00:00 | DENIED | | | | | | COMMENTS FROM LAST REVIEW NOT APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-09-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-28 |
Time |
10:44 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2001-09-27 |
Time |
19:57 |
Sent To |
|
|
| Notes |
| 2001-09-28 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) PAGE P-4, WATER ISOMETRIC DIAGRAM. | | | AIR CHAMBERS ARE A "TEMPORY FIX" AND ARE | | | IMPRACTICAL AND SERVE NOT PURPOSE. IF | | | INSTALLED THEY WILL HAVE TO BE RECHARG- | | | ABLE PER WH-PDI 201 WITH A SHUT OFF | | | VALVE, A DRAIN VALVE AND AN AIR INTAKE | | | VALVE AT THE TOP. WATER HAMMER ARRESTORS | | | SHALL BE LOCATED PER WH-PDI 201 AND MAN- | | | UFACTURE INSTALLATION INSTRUCTIONS NOT | | | AT THE TOP OF DROP AS SHOWN ON PLANS. | | | PLEASE SHOW PROPER LOCATION OF WATER | | | HAMMER ARRESTORS ON WATER ISOMETRIC. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
| Sent By |
tsuffiel |
Date |
2001-08-13 |
Time |
19:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2001-08-13 |
Time |
19:43 |
Sent To |
|
|
| Notes |
| 2001-08-13 00:00:00 | DENIED; | | | 1.P-1 SEWER REQUIRES CLEANOUTS EVERY | | | 80 FEET. 94 SPC SEC.710.2.4. | | | 2.SHOW STORM WATER CALKULATIONS. USE 4.5 | | | INCHES OF RAIN PER FIG. 1108.4 AND ADD | | | 1/2 OF THE PARAPIT WALL IN CALKS. | | | 3.CANOPY ROOF DRAIN SHALL DRAIN TO | | | STORM SEWER SYSTEM. SPC 1101.2. | | | 4.PAGE P-5 NOTE 8 VI NO DRAWING FOR | | | COMPRESSED AIR OR OIL PIPING. PLEASE | | | SUBMIT. | | | 5.APPROVED ENGINEERED MECHANICAL WATER | | | HAMMER ARRESTERS SHALL BE SIZED PER | | | SPC SEC. 607.8.2 AND 607.8.3 AND | | | INSTALLED PER MANUFACTORS SPECIFICA- | | | TIONS. | | | 6.SHOW ON DRAWING COMPLIANCE TO MINIMUM | | | PLUMBING FACILITIES PER. 94 SPC TABLE | | | 407. | | | 7.LOUNGE SINK SHALL COMPLY WITH FACBC | | | 4.24.2, 4.24.4,4.24.5,AND 4024.7. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-09-20 |
Time |
11:30 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-07-31 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-07-31 |
Time |
09:07 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-31 00:00:00 | NEED PLANNING APPROVAL |
|
|