Plan Review Details - Permit 01071328
Plan Review Stops For Permit 01071328
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-03-21 Cont ID  
Sent By jwitmer Date 2002-03-21 Time 13:25 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-03-21 00:00:002ND SET OF SUBMITTALSOK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-10-09 Cont ID  
Sent By jwitmer Date 2001-10-09 Time 16:35 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-10-09 00:00:00BUILDINGPROVISO: COUNTY IMPACT FEES TO
 BE PAIDED
 STATE RADON REQUIRES PAYMENT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-09-26 Cont ID  
Sent By jwitmer Date 2001-09-26 Time 06:53 Rev Time 5.00
Received By jwitmer Date 2001-09-26 Time 06:52 Sent To  
Notes
2001-09-26 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01071328
 2801 OKEECHOBEE BLVD.
 TEL: (954) 781 2120
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS TO 1997 STANDARD BUILD-
 ING CODE
 FL ACCES CODE= FLORIDA ACCESSIBILITY
 CODE 1997 EDITION
  
 1)- A COMMENT FROM PREVIOUS PLAN REVIEW
 IS ABOUT THE "OMEGALITE PANELS" REGARD-
 ING FIRE RATING IN A FIRE DISTRICT, WHAT
 IS NOT CLEAR ON SHEET S-6 DETAILS 4&5
 THE COMPOSITE SHEET IS MADE OF? THE DE-
 TAILS SHOW THAT IT HAS A PLYWOOD BACKING
 WE ARE TAKING THAT THIS IS NOT PART OF
 THE COMPOSITE PANEL BUT A BACKING MATER-
 IAL TO ATTACH THE PANELS TO. SBC FI02.1
 & F102.7 ARE FOR ARCHITECTURAL TRIM LOCA
 TED IN A FIRE DISTRICT,NONCOMBUSTIBLE OR
 FIRE RETARDANT TREATED PLYWOOD.
  
 2)-THE TEST THAT ARE INDICATED ARE FOR
 INTERIOR FLAME SPREAD AND SMOKE DEVELOP-
 MENT, BY DEFINITION NONCOMBUSTIBLE CAN
 BE TESTED (2) DIFFERENT WAYS,DEPENDING
 ON THE THICKNESS OF THE MATERIAL THERE
 HAS BEEN NO SPECS ON THIS MATERIAL AS TO
 THICKNESS NOR THE FASTENING OF THE
 SYSTEM TO WHATEVER MATERIAL THAT WILL BE
 SUPPORTING THE COMPOSITE PANELS.THE 2
 METHOSOF TESTING ARE ASTM E 136 &
 ASTM E 84 WHEN THE MATERIALS HAVING A
 STRUCTURAL BASE OF NONCOMBUSTIBLE
 MATERIALS AS DEFINED IN 1, WITH A SURFAC
 ING NOT MORE THAN 1/8" THICK AND A
 FLAMESPREAD RATING OF NOT MORE THAN 50
 WHEN TESTED IN ACCORDANCE WITH ASTM E 84
  
 3)-MISSING ARE PRODUCT APPROVAL REPORTS
 FOR THE OVERHEAD GARAGE DOORS, THE EXTER
 IOR DOOR 2ND FLOOR, AND THE ROOFING
 REPORT. THE CITY ACCEPTS SBCCI TESTING
 REPORTS & DADE COUNTY, (2) COPIES OF
 EACH REPORT.SBC 1606.2.6.2
  
 4)- S-6 DETAILS 4 & 5 WHAT IS THE MINI-
 MUM WORKING DEPTH FOR TAPCONS IN THE 2X8
 PT FOR CONCRETE?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-08-13 Cont ID  
Sent By hpiskura Date 2001-08-13 Time 08:49 Rev Time 0.00
Received By hpiskura Date 2001-08-08 Time 08:10 Sent To  
Notes
2001-08-13 00:00:00PLEASE PROVIDE A DIMENSIONED SITE PLAN
 SO THAT COMPLIANCE WITH SBC TABLE 600
 MAY BE DETERMINED.
  
 CLEARLY SHOW THE MIXED OCCUPANCY
 SEPARATIONS FOR THE B, M, AND S (REPAIR
 GARAGE)SEE SBC 411.5, SBC 704.1.
  
 HOW WILL HANDICAP ACCESS TO THE LOUNGE
 FROM THE SHOWROOM BE ACCOMPLISHED?SEE
 FACBC 4.1.1.
  
 THERE ARE NO ROOF OVERFLOW SCUPPERS
 SHOWN FOR THE SERVICE / RECEPTION
 CANOPY.SEE SBC 1517.6.4.3.
  
 THE AREA SHOWN AS A "MEZZANINE" DOES NOT
 MEET THE CRITERIA OF SBC 503.2.3 AND
 THEREFORE MUST COMPLY WITH STORY
 REQUIREMENTS, AS TO EGRESS AND FIRE
 RATED SEPARATIONS.ALSO, SEE SBC
 F102.2.5 FOR FIRE RESISTANT
 CONSTRUCTION REQUIREMENTS FOR BUILDINGS
 LOCATED INSIDE THE DESIGNATED FIRE
 DISTRICT.
  
 PLEASE PROVIDE TEST DATA THAT THE
 "OMEGALITE PANELS" ARE LISTED AS
 NON-COMBUSTIBLE OR FIRE RETARDANT.SEE
 SBC F102.1 AND F102.7
  
 PROVIDE SPECIFIC STRUCTURAL CONNECTION
 DETAILS FOR THE PANELS.
  
 THE STORE FRONT PRODUCT ACCEPTANCE
 REPORTS PROVIDED ARE EXPIRED AND HAVE
 SOME ILLEGIBLE PAGES.
  
 IMPACT FEES MUST BE PAID TO THE COUNTY
 BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED.CALL 561-233-5025 FOR MORE
 INFORMATION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-09-28 Cont ID  
Sent By dpalmer Date 2001-09-28 Time 07:22 Rev Time 0.00
Received By dpalmer Date 2001-09-28 Time 07:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-08 Cont ID  
Sent By dpalmer Date 2001-08-08 Time 21:56 Rev Time 0.00
Received By dpalmer Date 2001-08-08 Time 21:56 Sent To  
Notes
2001-08-08 00:00:00**************** UNSAT *************
  
 1)NOTE: PLEASE NOTE MISSING OUTLETS FOR
 SHOW ROOM WINDOWS PER 210-62
  
 20NOTE: PLEASE NOTE THAT OANS ARE SHOW-
 -ING THE SAME WIRE COUNT FROM GUTTER TO
 MAINS AND FROM MAINS TO PANELS. PLEASE
 NOTE THAT WIRE SCHEDULE IS SHOWING AN
 EQUIPMENT GROUNDING CONDUCTOR FROM
 GUTTER TO FIRST MEANS OS DISCONNECT.
 THIS MEANS THE GROUND WOULD BE PARALLEL-
 ING THE NEUTRAL. NOT PERMITTED PER 250
 OF NEC.
  
 3)NOTE: PLEASE CLARIFY THAT MAIN 2 OF 5
 SHOWN AS 200AMPS W/ 4/0 CONDUCTORS AND
 MAIN 4 OF 5 SHOWN AS 200AMPS ALSO BUT
 WITH 3/0`S?
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 NOTES 1&2 FOR REVIEW. NOTE 3 WAS JUST
 FOR CLARIFICATION. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-08-15 Cont ID  
Sent By mamini Date 2001-08-15 Time 09:24 Rev Time 3.00
Received By mamini Date 2001-08-15 Time 09:24 Sent To  
Notes
2001-08-15 00:00:00PASSED :
 1. ANY NEW CONNECTIONS TO THE CITY'S
 SERVICES WILL REQUIRE A SEPARATE PERMIT
 FROM PUBLIC UTILITIES ENGINEERING
 SERVICES DEPARTMENT,659-8040.
 2. ANY WORK WITHIN PUBLIC R.O.W WILL
 REQUIRE A SEPARATE PERMIT FROM THE CITY
 ENGINEER'S OFFICE,659-8040.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-09-27 Cont ID  
Sent By mcarsill Date 2001-09-27 Time 14:52 Rev Time 0.00
Received By mcarsill Date 2001-09-27 Time 14:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-02 Cont ID  
Sent By mcarsill Date 2001-08-02 Time 18:22 Rev Time 0.00
Received By mcarsill Date 2001-08-02 Time 18:22 Sent To  
Notes
2001-08-02 00:00:001) GATES ARE TO BE 20 FEET IN CLEAR
 WIDTH WHEN OPENED. WHAT PROVISIONS
 HAVE BEEN MADE FOR FIRE AND PARAMEDICAL
 ACCESS INTO THE COMPLEX.
 2) BUILDING ADDRESS TO COMPLY WITH
 CITY CODE 3343-00.
 3) PROVIDE OCCUPANT LOAD CALCULATIONS
 AND A LIFE SAFETY PLAN TO THIS OFFICE.
 4) NO INTERIOR FINISH CLASSIFICATION
 INFORMATION FOR WALLS AND CEILINGS
 PROVIDED WITH PLANS.
 5) HOW WILL VEHICLES BE DISPLAYED IN
 SHOWROOM. WHAT SAFETY PRECAUTIONS ARE
 PLANNED.
 6) PROVIDE SEPARATE PLANS AND PERMITS
 FOR FIRE ALARM SYSTEM INSTALLATION.
 7) PROVIDE SEPARATE PLANS AND PERMITS
 FOR FIRE SPRINKLER SYSTEM INSTALLATION.
 8) SERVICE CANOPY TO BE AT LEAST
 13"- 6" HIGH.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-06-12 Cont ID  
Sent By pkrauss Date 2002-06-12 Time 16:22 Rev Time 0.25
Received By pkrauss Date 2002-06-12 Time 16:22 Sent To  
Notes
2002-06-12 00:00:00TEST & BALANCE REPORT SUBMITTAL

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-13 Cont ID  
Sent By pkrauss Date 2002-03-13 Time 12:53 Rev Time 0.45
Received By pkrauss Date 2002-03-13 Time 12:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-08-14 Cont ID  
Sent By ndenmark Date 2001-08-14 Time 13:00 Rev Time 0.50
Received By ndenmark Date 2001-08-14 Time 13:00 Sent To  
Notes
2001-08-14 00:00:00PROVISO:
 SEPARATE PERMITS ARE REQUIRED FOR FUEL,
 INCLUDING OIL AND USED OIL STORAGE.

Review Stop P PLUMBING
Rev No 4 Status F Date 2002-05-14 Cont ID  
Sent By kstevens Date 2002-05-14 Time 15:51 Rev Time 0.00
Received By kstevens Date 2002-05-14 Time 15:51 Sent To  
Notes
2002-05-14 00:00:00DENIED
  
 CHANGES ON A SIGNED AND SEALED SHALL BE
 INITIALED AND DATED BY ENGINEER/ARCHITEC
 T OF RECORD
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-10-05 Cont ID  
Sent By kstevens Date 2001-10-05 Time 16:00 Rev Time 0.50
Received By kstevens Date 2001-10-05 Time 08:54 Sent To  
Notes
2001-10-05 00:00:00DENIED
  
 COMMENTS FROM LAST REVIEW NOT APPROVED.

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-09-28 Cont ID  
Sent By kstevens Date 2001-09-28 Time 10:44 Rev Time 0.75
Received By kstevens Date 2001-09-27 Time 19:57 Sent To  
Notes
2001-09-28 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PAGE P-4, WATER ISOMETRIC DIAGRAM.
 AIR CHAMBERS ARE A "TEMPORY FIX" AND ARE
 IMPRACTICAL AND SERVE NOT PURPOSE. IF
 INSTALLED THEY WILL HAVE TO BE RECHARG-
 ABLE PER WH-PDI 201 WITH A SHUT OFF
 VALVE, A DRAIN VALVE AND AN AIR INTAKE
 VALVE AT THE TOP. WATER HAMMER ARRESTORS
 SHALL BE LOCATED PER WH-PDI 201 AND MAN-
 UFACTURE INSTALLATION INSTRUCTIONS NOT
 AT THE TOP OF DROP AS SHOWN ON PLANS.
 PLEASE SHOW PROPER LOCATION OF WATER
 HAMMER ARRESTORS ON WATER ISOMETRIC.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-13 Cont ID  
Sent By tsuffiel Date 2001-08-13 Time 19:22 Rev Time 0.00
Received By jleech Date 2001-08-13 Time 19:43 Sent To  
Notes
2001-08-13 00:00:00DENIED;
 1.P-1 SEWER REQUIRES CLEANOUTS EVERY
 80 FEET. 94 SPC SEC.710.2.4.
 2.SHOW STORM WATER CALKULATIONS. USE 4.5
 INCHES OF RAIN PER FIG. 1108.4 AND ADD
 1/2 OF THE PARAPIT WALL IN CALKS.
 3.CANOPY ROOF DRAIN SHALL DRAIN TO
 STORM SEWER SYSTEM. SPC 1101.2.
 4.PAGE P-5 NOTE 8 VI NO DRAWING FOR
 COMPRESSED AIR OR OIL PIPING. PLEASE
 SUBMIT.
 5.APPROVED ENGINEERED MECHANICAL WATER
 HAMMER ARRESTERS SHALL BE SIZED PER
 SPC SEC. 607.8.2 AND 607.8.3 AND
 INSTALLED PER MANUFACTORS SPECIFICA-
 TIONS.
 6.SHOW ON DRAWING COMPLIANCE TO MINIMUM
 PLUMBING FACILITIES PER. 94 SPC TABLE
 407.
 7.LOUNGE SINK SHALL COMPLY WITH FACBC
 4.24.2, 4.24.4,4.24.5,AND 4024.7.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop Z ZONING
Rev No 2 Status P Date 2001-09-20 Cont ID  
Sent By sgraham Date 2001-09-20 Time 11:30 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2001-07-31 Cont ID  
Sent By sgraham Date 2001-07-31 Time 09:07 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-07-31 00:00:00NEED PLANNING APPROVAL