| Plan Review Stops For Permit 01071207 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-01-16 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-01-16 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-01-16 |
Time |
18:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-10-03 |
Time |
14:09 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-08-28 |
Time |
10:40 |
Rev Time |
3.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-28 00:00:00 | BUILDING COMMENTS | | | ----------------- | | | | | | PROVISO | | | ------- | | | | | | PROVIDE SIGNED AND SEALED | | | CERTIFICATION FROM A STRUCTURAL | | | ENGINEER VERIFING EXISTING ROOF | | | STRUCTURE WILL SUPPORT ADDITIONAL LOADS | | | IMPOSED BY NEW INSTALLATION. | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-659-8096 | | | #8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-04 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-04 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-30 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-30 |
Time |
18:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-24 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-24 |
Time |
14:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-07 |
Time |
22:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-07 |
Time |
22:55 |
Sent To |
|
|
| Notes |
| 2001-08-07 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT THE NEW SERVICE | | | SHOWN IS NOT PERMITTED UNDER 230-2, | | | | | | 2)NOTE: PLEASE NOTE GROUPING OF MAINS | | | PER 230-72. PLEASE NOTE THAT A SHUNT | | | TRIP AT EXSITING SERVICE LOCATION DOES | | | NOT MEET 230-76 AND 230-79 FOR MEANS OF | | | DISCONNECT. | | | | | | 3)NOTE: PLEASE NOTE THAT ALL CONTINUOUS | | | LOADS NEED TO BE SHOWN AT 125%. | | | PER 215-2 AND 230-42. | | | | | | PLEASE SUBMIT CLARIFICATION ON LOCATION | | | OF SERVICES. | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2002-01-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-01-07 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-01-07 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-30 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-30 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-18 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-18 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | 1) CONDUITS IN STAIR TOWER BEING SHOWN | | | AS BEING BOXED OUT WITH 2 HOUR RATED | | | DRY WALL ENCLOSURE. AGAIN, NOTHING IS | | | PERMITTED TO BE LOCATED WITHIN THE STAIR | | | TOWER EXCEPT FOR FIRE PROTECTION PIPING | | | AND ELECTRICAL EQUIPMENT USED FOR | | | EMERGENCY LIGHTING. PLEASE REFER TO LIFE | | | SAFETY CODE, CHAPTER 5-1.3.2 | | | 2)NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. THE NEXTEL ROOM MUST BE FIRE | | | SPRINKLER PROTECTED EVEN WITH THE | | | INSTALLATION OF THE FM 200 SYSTEM. | | | PLEASE SUBMIT FIRE SPRINKLER DRAWINGS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 832-2910 OR 659-8096 EXT. 8497 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-09 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-09 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2001-08-09 00:00:00 | 1) THE NEW CONDUIT TO SAME PATH AS | | | EXISTING 3" PIPE SHOWN ON E-1 CANNOT | | | RUN THRU STAIRTOWER. NOTHING IS | | | PERMITTED TO ENTER THE STAIR EXCEPT | | | FIRE PROTECTION PIPING AND ELECTRICAL | | | EQUIPMENT USED FOR EMERGENCY LIGHTING. | | | 2) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE INSTALLATION OF THE FM 200 | | | SYSTEM. THE FM 200 SYSTEM CANNOT | | | BE USED IN LIEU OF REQUIRED FIRE | | | SPRINKLER PROTECTION. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-01-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-09 |
Time |
14:18 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-01-09 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2002-01-09 00:00:00 | MECH PERMIT 01071243 | | | | | | PROVISO: | | | | | | AS PER 1997 SMC 304.6.3, EVERY APPLIANCE | | | ON AN EXTERIOR WALL OF A BUILDING, WHICH | | | IS SO DESIGNED THAT THE COMPONENTS ARE | | | SERVICABLE ONLY FROM OUTSIDE THE | | | BUILDING, SHALL BE ACCESSIBLE.SHOULD | | | EQUIPMENT HEIGHT BE GREATER THAN 20' | | | ABOVE THE LOW ROOF A PERMENENT MEANS OF | | | ACCESS IS REQUIRED. | | | | | | A MINIMUM OF 30" OF CLEAR SPACE ON THE | | | SERVICE SIDE FOR INSPECTION AND | | | SERVICING OF CONDENSING UNITS OR | | | COMPRESSOR UNITS WITH ENCLOSURES SHALL | | | BE ACCESSIBLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-11-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-13 |
Time |
09:13 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-11-13 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2001-11-13 00:00:00 | ******************PROVISO*************** | | | | | | | | | MECHANICAL PERMIT 01071243 | | | | | | 1.DUCT SMOKE DETECTORS ARE REQUIRED | | | IF MORE THAN ONE AIR HANDLING UNIT | | | ARE TO BE RUN AT ANY GIVEN TIME. | | | (CFM WOULD BE GREATER THAN 2000 CFM) | | | | | | | | | 2.DUCT SMOKE DETECTORS SHALL BE TIED | | | BUILD BUILDING ALARM SYSTEMS AS PER | | | NFPA 90A 4-4.4.2. | | | | | | NOTE, CONDENSERS MOUNTED ON WALL SHALL | | | BE ACCESSIBLE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-21 |
Time |
08:54 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-08-21 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2001-08-21 00:00:00 | PROVISO: | | | DUCT SMOKE DETECTORS SHALL BE REQUIRED | | | IF MORE THAN ONE AIR HANDLING UNIT ARE | | | TO RUN AT ANY GIVEN TIME. CFM WOULD BE | | | GREATER THAN 2000CFM FOR THE AGGREGATE | | | AREA. TIE TO BLDG ALARM. | | | SEPARATE PERMIT AND PLANS WILL BE | | | REQUIRED FOR THE FM200 SUPPRESSION | | | SYSTEM. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-08-06 |
|
|
Cont ID |
|
| Sent By |
sjohnson |
Date |
2001-08-06 |
Time |
09:21 |
Rev Time |
0.25 |
| Received By |
sjohnson |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-06 00:00:00 | APPROVED PER SHIRLEY GRAHAM |
|
|