| Plan Review Stops For Permit 01071119 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2001-12-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-12-06 |
Time |
06:37 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2001-12-06 |
Time |
06:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-14 |
Time |
17:11 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
2001-11-14 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2001-11-14 00:00:00 | BUILDING PLAN REVIEW | | | 700 S ROSEMARY # 204 | | | PLAN REVIEW " 01071119 | | | ARCH: CRAIG MOSSEY | | | TEL: (561) 416-9059 | | | FAX: (561) 416-9058 | | | BOCA RATON, FL 33486 | | | SBC=1997 STANDARD BUILDING CODE | | | SBC* AMENDMENTS/ STANDARD BUILDING CODE | | | | | | 1)- SBC 903.5 (1) FIRE SPRINKLER PLANS | | | ARE REQUIRED FOR TYPE II CONSTRUCTION, | | | TOBE SUBMITTED AS PART OF THE BUIULDING | | | PERMIT PACKAGE. A SEPERATE PERMIT PLANS | | | AND FEES SHALL BE REQUIRED. | | | | | | 2)-NORTH WALL FIXED SEATING AT RAMP # 3 | | | SHALL BE A MINIMUM OF 3'-8", A REDDUC- | | | TION OF 1'-0" FOR THE FIXED SEATING | | | AGAINST THE NORTH WALL,(SEE SBC1019.10.3 | | | .3) THE EGRESS ISLE THEN HAS 2'-8". | | | | | | 3)- SHEET A2.0 WEST TENANT SEPERATION | | | WALL IS INDICATED AS A 1 HR.WALL, SBC | | | 704.1 ASSEMBLY REQUIRES A 2 HR SEPERA- | | | TION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2001-09-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-17 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-10-25 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2001-09-17 00:00:00 | BUILDING PLAN REVIEW | | | 700 S ROSEMARY AVE | | | PERMIT # 01071119 | | | "NV LONGE" | | | ARCHITECT: CRAIG MOSSEY | | | TEL: (561) 416-9059 | | | FAX: (561) 416-9058 | | | BOCA RATON, FL 33486 | | | SBC= 1997 STANDARD BUILDING CODE | | | FL ACC CODE= 1997 FLORIDA ACCESSIBILITY | | | CODE | | | | | | 1)_ FROM PREVIOUS REVIEW: SBC 1204.2 | | | RESTROOMS SHALL HAVE NONABSORBANT FLOORS | | | AND WALLS TO A HEIGTH OF 4'-0". | | | | | | 2)- FROM PREVIOUS REVIEW: FL ACC CODE | | | 4.5.1. FLOOR SURFACES ALONG ACCESSIBILE | | | ROUTES AND IN ACCESSIBLE ROOMS AND | | | SPACESINCLUDING FLOORS, WALKS,STAIRS | | | CURBS AND RAMPS SHALL BE FIRM, STABLE | | | AND SLIP RESISTANT. A STATIC COEFFICIENT | | | OF FRICTION OF 0.6 IS RECOMMENDED FOR | | | FLOORS AND 0.8 FOR RAMPS. | | | | | | 3)- DOORS E-1, E-2 PROVIDE PRODUCT INFOR | | | MATION FOR 2 HR. FIRE RATING FOR DOORS | | | AND THE TRANSOMS ABOVE.WINDOWS 1-4 AL- | | | SO WILL REQUIRE 2 HR. FIRE RATING. DOOR | | | X-1 INDICATES FLUSH SHOW DETAIL FOR 1HR | | | RATING AND THE HARDWARE FOR THE DOOR, | | | SBC 1012.1.2 (1-3). | | | | | | 4)- FROM PRREVIOUS REVIEW ; ADDITIONAL | | | INFORMATION REQUIRED, SHEET A7.1 DETAIL | | | #4, 3" MEDIUM DENSE FOAM, FLAME & SMOKE | | | DEVELOPMENT. | | | | | | 5)- REVOLVING DOORS SBC 1012.3(1-6) | | | ENTRANCE DOORS AT LOUNGE #2 ARE TO COM- | | | PLY. THERE IS ALAO A DISCREPANCY FROM | | | SHEET A.2 AND AC.1, P1 & E.1. THE SUB | | | TRADE SHEETS SHOW A AWING DOOR WHWEREAS | | | A.2 DOESN'T? | | | | | | 6)- FROM PREVIOUS REVIEW, SBC 403.2.4. | | | PLATFORM CONSTRUCTION, FOR RAISED PLAT- | | | FORMS & RAMPS. FLOORS ARE TO BE BUILT AS | | | A TYPE II BUILDING CONSTRUCTION. LIVE | | | LOADS AS PER CHAPTER 16. 100 LBS/ SQ FT. | | | TABLE 600 TYPE II CON. FLOORS (2HR. RAT- | | | ING) NONCOMBUSTIBLE 604,609.2.1, | | | FLOOR FINISH 803.7.1, SEE SBC SEC 706, | | | 707. | | | AC-1 INDICATES A/C DUCTS BENEATH PLAT- | | | FORM, E.2 (D) INDICATES THAT THERE ARE | | | TO BE RECESSED LIGHTS IN FLOORING PLEASE | | | DETAIL. | | | | | | 7)- DISCREPANCY, AREA 21 DANCE AREA VIP | | | 2'-4" ELEVATION VS. DETAIL 6/A9.2. | | | | | | 8)- SBC 903.5 (1) FIRE SPRINKLER PLANS | | | ARE REQUIRED FOR TYPE II CONSTRUCTION. | | | | | | 9)- SHEET A.9.1 SEC 8 2X4 BLOCKING. | | | SBC 609.2.1 NONCOMBUSTIBLE MATERIALS | | | FRAMING & BACKING IN WALLS, FIRE RESIS- | | | TANT TREATED WOOD MAY BE USED. | | | | | | 10)- FROM PREVIOUS REVIEW, SHEET A9.3 | | | HANGING CEILING DETAILS, EXPANSION BOLTS | | | INTO EXISTING SLAB? TYPE OF ANCHOR?DEPTH | | | OF ANCHOR? | | | | | | 11)- LETTER FROM ENGINEER FOR THE ADDITI | | | ONAL LOADING OF BAR JOIST, THAT THE BAR | | | JOIST WILL TAKE THE ADDITIONAL LOADING. | | | AC.2 ROOF CURB DETAILS : NOTE #4 SEE | | | STRUCTURAL DETAILS, THERE ARE NONE? | | | THE ADDITIONAL LOADS FOR THE AIR HAND- | | | LERS DOESN,T INDICATE IF THE LOADS ARE | | | BEING TRANSFERED TO THE TOP OR BOTTOM | | | CORD OF THE BAR JOIST, PLEASE HAVE THE | | | ENGINEER OF RECORD INDICATE? | | | | | | 12)- A9.3 SECTION #2 FINISH INFORMATION | | | ON THE SUSPENDED DOME. SMOKE DEVELOPMENT | | | AND FLAME SPREAD. | | | | | | 13)- ROOF /CEILING ASSEMBLY: TABLE 600 | | | 1 HR PROTECTED FOR TYPE II STRUCTURE | | | (BAR JOIST) SHOW COMPLIANCE. | | | | | | 14)- A1.0 NORTH WALL FIXED SEATING AT | | | RAMP # 3 3'-8" REQUIRED, MINIMUM. | | | SBC 1019.10.3.3 SUBTRACT 12" FOR THE | | | FIXED SEATING AGAINST THE NORTH WALL. | | | ACCESS ISLE NOW ONLY HAS 2'-8" NOT LEGAL | | | | | | | | | 15)- A 1.0 AT THE FOOT OF RAMP #1 AND AT | | | THE END OF RAMP #2 "HATCHED MARKS" | | | INDICATING WHAT? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-08-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-17 |
Time |
14:29 |
Rev Time |
6.00 |
| Received By |
jwitmer |
Date |
2001-08-17 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2001-08-17 00:00:00 | BUILDING PLAN REVIEW | | | 700 S ROSEMARY AVE # 204 | | | PERMIT # 01071119 | | | "N V LOUNGE" | | | ARCHITECT: | | | GUILLERMO GOMEZ | | | TEL : (212) 628-7276 | | | FAX : (212) 585-2251 | | | 119 E 64 STREET | | | NW YORK NY 10021 | | | | | | 1)- MISSING : COMMON ENTRY AREA( NOT | | | TENANT SPACE) EXIT ACCESS DOOR MISSING | | | SBC 1005.3 | | | | | | 2)-SBC 1204.2 RESTROOMS SHALL HAVE | | | NONABSORBEANT FLOORS & WALLS TO A HEIGHT | | | OF 4'-0". | | | | | | 3)- FLORIDA ACCESSIBILITY CODE 4.5.1. | | | FLOOR SURFACES ALONG ACCESSIBLE ROUTES | | | AND IN ACCESSIBLE ROOMSAND SPACES IN- | | | CLUDING FLOORS, WALKS,STAIRS AND CURB | | | RAMPS SHALL BE FIRM, STABLE AND SLIP RE- | | | SISTANT. A STATIC COEFFICIENT OF FRIC- | | | TION OF 0.6 IS RECCOMMENDED FOR FLOORS | | | AND 0.8 FOR RAMPS. | | | | | | 4)- SHEET 5.1 DOOR SCHEDULE HASN'T ANY | | | CORRESPONDING NUMBERS ON FLOOR PLAN NOR | | | THE LIFE SAFETY? | | | COMMENT: THERE SHOULD BE 5 RATED DOORS | | | FROM THE TENANT SPACE DOOR SCHEDULE DOES | | | NOT INDICATE THIS. RATE THE EXIT ACCESS | | | DOOR OUTSIDE OF THE TENANT SPACE. | | | | | | 5)- SBC 104.2.2. ADDITIONAL INFORMATION | | | REQUIRED ON SHEET A7.1 DETAIL #4, 3" | | | MEDIUM DENSE FOAM, FLAME & SMOKE DEVELOP | | | MENT | | | | | | 6)- SBC 104.2.2. SHEET A 7.1 DETAIL #3 | | | STEEL LAADDER? USAGE? IT LOOKS LIKE IT | | | MAY INTERFERE WITH THE EGRESS. IF THE | | | USAGE IS LIGHT STORAGE THE SBC 1606.4 | | | FOR LIGHT STORAGE IS 125 LBS/ SQ FT. | | | HOW IS THIS FLOOR AREA HELD UP? IF THIS | | | AREA IS A DANCE FLOOR, VERTICAL ACCESS- | | | IBILITY REQUIREMENTS ARE TO BE MET. | | | | | | 7)- DOOR OPENING JUST LEFT OF BAR # 1. | | | THE DOOR SWING DOES NOT MEET THE EGRESS | | | REQUIREMENTS, SBC 1012.1.2. SWING IN THE | | | DIRECTION OF EGRESS (1) WHICH SSERVE | | | AN OCCUPANT LOAD OF 50 OR MORE PEOPLE. T | | | HE SAME CONCERNS ARE RAISED WHERE (2) | | | SETS OF DOORS PIVOT! | | | | | | 8)- SBC 403.2.4 PLATFORM CONSTRUCTION | | | FOR RAISED PLATFORMS & RAMPS. FLOORS ARE | | | TO BE BUILT AS TYPE II CONSTRUCTION, | | | LIVE LOADS AS PER CHAPTER 16 / 100 LBS/ | | | SQ. FT. | | | | | | 9)- SBC 903.5.(1) FIRE SPRINKLER PLANS | | | ARE REQUIRED TYPE II CONSTRUCTION. | | | | | | 10)- SHEET A9.1 SBC 609.2.1. NONCOMBUST- | | | IBLE MATERIAL FRAMING & BACKING IN WALLS | | | FIRE RESISTANT TREATED PLYWOOD MAY BE | | | USED. | | | | | | 11)- SHEET A 9-3 HANGING CEILING DETAILS | | | EXP BOLT W/ BOLT HANGERS INTO EXISTING | | | SLAB? TYPE OF HANGER? DEPTH OF ANCHOR, | | | WIDTH OF ANCHORNOT GIVEN, NOR THE | | | ATTACHMENT TO 1/4" STEEL. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-07-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-07-24 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-08-17 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2001-07-24 00:00:00 | BUILDING COMMENTS | | | ----------------- | | | | | | PLANS ARE INCOMPLETE. | | | PLEASE PROVIDE COMPLETE SET OF | | | DRAWINGS,DETAILS AND SPECIFICATIONS. | | | | | | | | | LUIS MARTINEZ | | | 561-659-8096 | | | #8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-05 |
Time |
20:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-05 |
Time |
20:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-07 |
Time |
20:07 |
Sent To |
|
|
| Notes |
| 2001-11-07 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE CLARIFY WHERE THE LOAD | | | CALCULATIONS ARE SHOWN AND WHERE THE | | | CONTINUOUS LOADS AT 125%.EVERYTHING IS | | | SHOWN AT CONNECTED LOAD. | | | 2)NOTE: PLEASE SHOW WHERE LOADS CALCS | | | ARE SHOWN FOR TRACK LIGHTING PER 220-12B | | | | | | 3)NOTE: PLEASE NOTE THAT THE ELECTRICAL | | | PLANS SHOW TRANSFORMER AND ASSC EQUIP- | | | -MENT ABOVE WALK-IN COOLER, BUT ARCH | | | DETAILS ON A3.0 SHOW A DIFFERENT LOCAT- | | | -ION? PLEASE SUBMIT A DETAIL ON THE | | | OPEN MOUNTING/PLATFORM FOR TRANSFORMER. | | | PLEASE NOTE THAT ALL MUST MEET 110-26 | | | AND 450-13 ECT | | | | | | 4)NOTE: PLEASE NOTE THAT NOTE ON PLANS | | | MENTION GC TO SUBMIT DETAILS FOR THE | | | TRANSFORMER PLATFORM/MOUNTING ETC. | | | THIS IS REQ`D TO BE SUBMITTED FOR | | | PLAN REVIEW.PLEASE SUBMIT BOTH ELECTRICA | | | L AND STRUCTURAL DETAILS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-18 |
Time |
22:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-18 |
Time |
22:00 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | ***************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SUBMIT DETAIL ON GROUND- | | | -ING OF TRANSFORMER PER 250-30 | | | | | | 2)NOTE: PLEASE NOTE THAT TRANSFORMER | | | SHOWN ON E.1 AND E.4 ARE TWO DIFFERENT | | | SIZES, PLEASE CLARIFY. | | | PLEASE PROVIDE STRUCTUAL MOUNTING | | | DETAIL ON E.4 FOR TRANSFORMER. | | | PLEASEKEEP IN MIND 450-9 AND 450-13 | | | | | | 3)NOTE: PLEASE NOTE AS PER LOCAL AMEND- | | | -MENTS:210-50 OUTLET SPACING IS EVERY | | | 20' OF UNENCUMBERED WALL SPACE. | | | PLEASE REVISE OUTLET LAYOUT. | | | | | | 4)NOTE: PLEASE NOTE ALL TRACK LIGHTING | | | CALCULATIONS TO BE SHOWN PER 220-12B | | | | | | 5)NOTE: PLEASE NOTE, ALL CONTINUOUS | | | LOADS ARE TO BE SHOWN AT 125%. PLEASE | | | NOTE 230-42 AND 215-2/3. | | | | | | 6)NOTE: PLEASE NOTE EQUIPMENT(DISCONNECT | | | -S FOR TRANSFORMER DO NOT MEET DEDICATED | | | ELECTRICAL SPACE PER 110-26. FLOOR TO | | | CEILING. PLEASE NOTE THAT THE TOP OF | | | WALK-IN COOLERS ARE ALOMOST ALWAYS USED | | | FOR STORAGE. PLEASE FIND A DEDICATED | | | SPACE PER. 110-26 AND 384-7. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-21 |
Time |
21:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-21 |
Time |
21:15 |
Sent To |
|
|
| Notes |
| 2001-08-21 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT NO ELECTRICAL | | | PLANS WERE SUBMITTED FOR REVIEW.?? | | | | | | PLEASE SUBMITPLANS FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-30 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-10 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-10 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-11-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-15 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-15 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2001-11-15 00:00:00 | 1) NO FIRE SPRINKLER PLANS PROVIDED | | | WITH DRAWINGS. | | | 2) TENANT DEMISING WALL ON PAGE A2.0 | | | INDICATES A ONE-HOUR FIRE RATING. | | | BUILDING CODE REQUIRES A TWO-HOUR | | | RATING. | | | 3) A PROBLEM SEEMS TO BE PRESENT WITH | | | THE BENCH SEATING AND AISLE REQUIREMENTS | | | NEAR CALL OUT 6A9.2. | | | 4) HOW WILL THE FOG MACHINE BE USED | | | AND HOW WILL IT AFFECT EXITING. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-14 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-14 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2001-08-14 00:00:00 | 1) PLATFORMS IF PERMANANT, ARE TO BE | | | CONSTRUCTED OF MATERIALS FO THE TYPE | | | OF CONSTRUCTION IN WHICH THE PLATFORMS | | | ARE LOCATED. | | | 2) PROVISIONS ARE TO BE MADE FOR AT | | | LEAST TWO HANDICAPPED PERSONS. | | | 3) THE SHARED FOYER MUST BE AT LEAST | | | 7'- 6" HIGH. ANY PROJECTIONS FROM THE | | | CEILING MUST BE AT LEAST 7'- 0 FROM THE | | | FINISHED FLOOR. | | | 4) PLEASE PROVIDE PRODUCT APPROVALS FOR | | | 2 HOUR FIRE PROOF TEMPERED GLASS AND | | | DOORS SHOWN ON THE DRAWINGS. | | | 5) NO ILLUMINATED EXIT SIGNS OR | | | EMERGENCY LIGHTS SHOWN. | | | 6) NO FIRE ALARM EQUIPMENT SHOWN ON THE | | | DRAWINGS. | | | 7) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-07-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-07-25 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-07-25 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2001-07-25 00:00:00 | 1) PLEASE INDICATE LOCATIONS OF ALL | | | ILLUMINATED EXIT SIGNS AND EMERGENCY | | | LIGHTING EQUIPMENT. | | | 2) NO INTERIOR FINISH PROVIDED WITH | | | PLANS. | | | 3) PANIC HARDWARE REQUIRED ON ALL EXIT | | | DOORS SUBJECT TO AN OCCUPANCY OF | | | 100 OR MORE PERSONS. | | | 4) PLEASE PROVIDE MORE DETAILS FOR RAMP. | | | 5) PROVISIONS ARE TO BE MADE FOR AT | | | LEAST TWO HANDICAPPED PERSONS. | | | 6) NO FIRE SPRINKLER DRAWINGS PROVIDED. | | | 7) NO FIRE ALARM EQUIPMENT SHOWN ON | | | DRAWINGS. | | | 8) HOW IS SMOKE REMOVED FROM THIS | | | INTERIOR SPACE SHOULD A FIRE DEVELOP. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-12-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-08 |
Time |
11:28 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-12-08 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-16 |
Time |
09:41 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-11-16 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-09-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-21 |
Time |
14:21 |
Rev Time |
2.00 |
| Received By |
pkrauss |
Date |
2001-09-21 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2001-09-21 00:00:00 | ******************DENIED**************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | | | | 1.AIR BALANCE SCHEDULE SHOWING | | | COMPLIANCE WITH 1997 SMC 501.2. | | | | | | 2.PROVIDE PLAN INDICATING TERMINATION | | | OF EXHAUST FANS. | | | | | | 3.INDICATE MATERIAL AND R-VALUE OF | | | DUCTWORK. | | | | | | 4.CLARIFY VENTILATION FOR RESTROOMS. | | | NO EXHAUST FANS ARE INDICATED ON | | | PLAN.AIR SHALL NOT BE RECIRCULATED | | | FROM THE RESTROOMS AS PER 1997 SMC | | | 503.3.1. | | | | | | 5.DO NOT SEE EXHAUST FANS F-5 AND F-6 | | | LOCATION ON PLAN. | | | | | | 6.ACCESS FOR AHU SHALL BE ADAQUATE FOR | | | SERVICE AND REPLACEMENT OF THE | | | LARGEST PIECE TO THE EQUIPMENT. | | | | | | 7.AUXILIARY DRAIN PAN SHALL HAVE OVER- | | | FLOW PROTECTION BY MEANS OF A FLOAT | | | SWITCH OR A DRAIN LINE TERMINATING | | | AT A CONSPICUOUS POINT TO SERVE AS | | | AN ALARM THAT THE REGULAR DRAIN IS | | | RESTRICTED. | | | | | | 8.PROVIDE DETAIL OF THE CONDENSER TO | | | WALK-IN COOLER.IF CONDENSER IS | | | LOCATED ON THE ROOF, PROVIDE A | | | DETAIL OF STAND AND HOW IT WILL BE | | | ATTACHED TO THE ROOF.18" MINIMUM | | | BETWEEN THE ROOF SURFACE AND THE | | | BOTTOM OF THE SUPPORT RAIL. | | | | | | NOTE:ADDITIONAL PERMIT REQUIRED FOR | | | WALK-IN COOLER.PROVIDE PLANS | | | AND MANUFACTURER SUBMITTAL DATA | | | WITH PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
R |
Date |
2001-08-23 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-23 |
Time |
09:18 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-08-23 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-08-23 00:00:00 | NO MECHANICAL INFORMATION SUBMITTED FOR | | | REVIEW, INCLUDING CODE REQUIRED MINIMUM | | | OUTSIDE AIR AND EXHAUST FOR BATHROOMS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-11-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-11-04 |
Time |
13:34 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-04 00:00:00 | PLUMBING PLAN REVIEW, APPROVED WITH | | | PREVIOUS COMMENTS ADDRESSED.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-12 |
Time |
09:20 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2001-09-12 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2001-09-12 00:00:00 | DENIED | | | REFERENCE SPC-94 - FACBC-97 | | | 1) COMMENT #1 FROM PLAN REVIEW 8-30 NOT | | | ADDRESSED. PLANS TO BE ROUTED TO THE | | | PALM BEACH COUNTY HEALTH UNIT, DIVISION | | | OF ENVIRONMENTAL HEALTH, (901 EVERNIA ST | | | WPB FLA 33401), (561) 355-3018 FOR PLAN | | | REVIEW BEFORE CITY OF WPB PLAN REVIEW. | | | 2) PAGE A4.1 FINISH SCHEDULE, PLEASE SUB | | | MIT MANUFACTURE INFORMATION ON THE PRO- | | | DUCT USED TO KEEP WALLS AND FLOORS NON- | | | ABSORBANT. (CARMINAR) | | | 3) PAGES P.1, P.2 & P.4 FD-2 SHOULD READ | | | FS-2 FOR FLOOR SINK. | | | 4) PAGE P.2 WATER HAMMER ARRESTORS TO BE | | | SIZED AND LOCATED PER MANUFACTURS INSTAL | | | LATION INSTRUCTIONS AND WH-PDI 201. NOT | | | ON TOP OF DROP AS SHOWN ON WATER RISER | | | DIAGRAM. | | | 5) PAGE P.2 WATER RISER DIAGRAM & WATER | | | RISER NOTES, PAGE P.5 PLUMBING SPECIFIC- | | | ATIONS #'S 7 & 8. AIR CHAMBERS SHALL | | | COMPLY WITH SPC-94 SECT'S. 607.8.2 & | | | 607.8.3 SHALL BE ACCESSABLE AND RECHARG- | | | ABLE. | | | 6) PAGE P.2 SANITARY RISER DIAGRAM. LAVS | | | NOT VENTED PROPERLY. SHOW VENT THRU ROOF | | | OR OTHER VENT DETAIL. | | | 7) PAGE P.2 SANITARY RISER DIAGRAM. | | | FUNNEL DRAINS NOT APPROVED, ALL INDIRECT | | | WASTE TO DRAIN TO FLOOR SINKS. SPC 804.5 | | | 8) PAGE P.3 WATER HEATER DETAIL. SHUT | | | OFF VALVE ON SUPPLY SIDE (COLD) TO BE | | | ACCESSABLE. PUT VALVE CLOSE TO HEATER. | | | 9) PAGE P.5 PLUMBING SPECIFICATIONS. #5 | | | HUB DRAINS NOT APPROVED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-30 |
Time |
09:18 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2001-08-30 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-08-30 00:00:00 | DENIED | | | | | | REFERENCES - SPC-94 - FACBC-97 | | | | | | 1) PLANS TO BE ROUTED TO THE PALM BEACH | | | COUNTY HEALTH UNIT, DIVISION OF ENVIRON- | | | MENTAL HEALTH (901 EVERNIA STREET WPB | | | FL 33401 - 561 355-3018 - FOR PLAN RE- | | | VIEW BEFORE CITY OF WPB PLAN REVIEW. | | | 2) NOT ENOUGH INFORMATION SUBMITTED. | | | PLEASE SUBMIT A SANITARY AND WATER RISER | | | DIAGRAM, CALCULATIONS FOR MINIMUM FAC- | | | ILITIES, (TABLE 407 SPC-94), SHOW LOCAT- | | | ION OF ALL BAR EQUIPMENT, AND SHOW LOC- | | | ATION OF ALL FLOOR DRAINS, AND FOR IN- | | | DIRECT WASTE ALL FLOOR SINKS. | | | 3) PAGE A10.1 BATHROOM STALL ELEVATION | | | SECTION 2. WATER CLOSET SHOWS 1'7" TO | | | CENTER AND IT SHOULD BE 1'6". | | | 4) PAGE A10.1 BATHROOM STALL ELEVATION | | | SECTION 3. 1 URNAL SHALL MEET FACBC-97 | | | 4.18 - 4.18.2 HEIGHT REQUIREMENT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|