Plan Review Details - Permit 01071052
Plan Review Stops For Permit 01071052
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-08-13 Cont ID  
Sent By hpiskura Date 2001-08-13 Time 15:46 Rev Time 0.00
Received By hpiskura Date 2001-08-13 Time 15:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-08 Cont ID  
Sent By dpalmer Date 2001-08-08 Time 07:18 Rev Time 0.00
Received By dpalmer Date 2001-08-08 Time 07:17 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-08-14 Cont ID  
Sent By kstevens Date 2001-08-14 Time 15:47 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-09-04 Cont ID  
Sent By mcarsill Date 2001-09-04 Time 10:40 Rev Time 0.00
Received By mcarsill Date 2001-09-04 Time 10:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By mcarsill Date 2001-07-25 Time 11:22 Rev Time 0.00
Received By mcarsill Date 2001-07-25 Time 11:22 Sent To  
Notes
2001-07-25 00:00:001) PLEASE PROVIDE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
 2) PLEASE PROVIDE MORE DETAILS ON QVENT.
 WHAT DOES THIS EQUIPMENT PROTECT. IF
 SMOKE OR GREASE LADEN VAPORS ARE EMITTED
 THEN A HOOD,DUCT, AND FIRE SUPPRESSION
 SYSTEM WILL BE REQUIRED THAT MEETS
 NFPA 33 AND NFPA 17.
  
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-14 Cont ID  
Sent By pkrauss Date 2001-09-14 Time 16:49 Rev Time 0.40
Received By pkrauss Date 2001-09-14 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-09 Cont ID  
Sent By pkrauss Date 2001-08-09 Time 11:48 Rev Time 0.50
Received By pkrauss Date 2001-08-09 Time 11:29 Sent To  
Notes
2001-08-09 00:00:00*******************DENIED***************
  
  
 PLEASE PROVIDE THE FOLLOWING INFOMRATION
 FOR REVIEW.
  
  
 1.AIR BALANCE SCHEDULE TO SHOW
 COMPLIANCE WITH 1997 SMC 501.2.
  
 2.FAN SHUTDOWN BY DUCT SMOKE DETECTOR
 WITH NOTIFICATION TO ALARM/STROBE
 AS PER 1997 SMC 406.1 AND NFPA 90A
 4-4.4.3.
  
 3.PLEASE INDICATE AS TO WHERE THE
 CONDENSATE IS TO TERMINATE.
  
 NOTE, CONDENSATE WILL FOLLOW THE
 PITCH OF THE ROOF SO LONG AS THE
 PITCH IS DOWN.
  
 NOTE:ADDITIONAL PERMITS REQUIRED FOR
 HOOD, FIRE SUPRESSION AND WALK
 IN COOLER/FREEZER.PLEASE
 SUBMIT PLANS AND MANUFACTURER
 SUBMITTAL DATA WITH PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-09-28 Cont ID  
Sent By kstevens Date 2001-09-28 Time 17:51 Rev Time 0.50
Received By kstevens Date 2001-09-28 Time 17:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-09-10 Cont ID  
Sent By kstevens Date 2001-09-10 Time 08:41 Rev Time 1.00
Received By kstevens Date 2001-09-07 Time 18:55 Sent To  
Notes
2001-09-10 00:00:00DENIED
  
 REFERENCE: SPC-94 - FACBC-97
  
 1) COMMENT #1 FROM PREVIOUS REVIEW NOT
 ADDRESSED. PLEASE COMPLY WITH RUNNING
 THE GREASE LINE SEPARATE FROM THE SANIT-
 ARY LINE. PAGE P-1
  
 2) PAGE P-1, WATER RISER DIAGRAM STILL
 SHOWS AIR CHAMBERS AT EACH FIXTURE.
 LOCATION OF WATER HAMMER ARRESTORS SHALL
 BE PER MANUFACTURE'S INSTALLATION IN-
 STRUCTIONS NOT AT TOP OF DROP AS SHOWN.
 PLEASE LOCATE ARRESTORS WHERE INSTRUCTED
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-14 Cont ID  
Sent By kstevens Date 2001-08-14 Time 15:33 Rev Time 1.75
Received By kstevens Date 2001-08-14 Time 15:23 Sent To  
Notes
2001-08-14 00:00:00DENIED
  
 1) GREASE LINE REQUIRED TO PICK UP FLOOR
 DRAINS, FLOOR SINKS, HAND SINKS, AND
 THREE COMPARTMENT SINK. MINIMUN 750 GAL
 GREASE TRAP REQUIRED. PLEASE CONTACT
 RODNEY COMPO AT WEST PALM BEACH UTILITY
 (561) 837-4074
  
 2) AIR CHAMBERS TO MEET SPC-94 REQUIRE-
 MENTS 607.8.2 & 607.8.3 - MUST BE RE-
 CHARGEABLE AND ACCESSABLE.
  
 3) PERMINATE SHIPS LADDER REQUIRED FOR
 WATER HEATER TO MAKE IT ACCESSABLE AND
 SERVICEABLE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2001-09-07 Cont ID  
Sent By lsmith Date 2001-09-07 Time 12:19 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***