Plan Review Details - Permit 01071019
Plan Review Stops For Permit 01071019
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-11-14 Cont ID  
Sent By jwitmer Date 2001-11-14 Time 09:35 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-11-14 00:00:00TRUSS PLANS 11/14/01 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-10-03 Cont ID  
Sent By jwitmer Date 2001-10-03 Time 06:52 Rev Time 0.75
Received By jwitmer Date 2001-10-03 Time 06:52 Sent To  
Notes
2001-10-03 00:00:00PAY IMPACT FEES & RADON FEES 10/3/01

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-08-27 Cont ID  
Sent By jwitmer Date 2001-08-27 Time 16:35 Rev Time 2.00
Received By jwitmer Date 2001-08-27 Time 14:45 Sent To  
Notes
2001-08-27 00:00:00BUILDING PLAN REVIEW:
 PERMIT: 01071019
 ADDRESS: 9042 LAKES BLVD
 CONT: STATHIS CONSTRUCTION
 TEL: (954) 275-1337
  
 1)- SHEET A-3 DETAIL #3, ADD. INFO. RE-
 QUIRED. IS THIS A EXISTING COLUMN OR A
 NEW COLUMN? LOADS IMPOSED? A FOUNDATION
 REQUIRED?
  
 2)- SHEET A-6 SHOWS A COLUMN WITH A MID-
 POINT BEARING POINT, WHERE IS THIS APPLI
 CATION USED? THIS SAME DETAIL REFRENCES
 (3) USES, A SINGGLE, DOUBLE & TRIPLE
 MEMBER TRUSS?
  
 3)- SHEET A-6 DETAIL #22 NOTES THAT
 1X2, 1X4 BUCKS WILL BE ATTACHED WITH "T"
 NAILS NO LENGTH IS GIVEN FOR THE NAIL
 OR MINIMUM EMBEDMENT.
  
 4)- A-6 DETAIL"A" NO INSILATION INFOR.
 IS GIVEN FOR ABOVE THE GARAGE CEILING.
  
 5)- SBC 104.2.2 ADD INFO. REQUIRED MISS-
 ING THE 2ND STORY ROOF FRAMING PLAN,
 TRUSS, GIRDER LOADS,VERTICAL / HORIZONT-
 AL AND GRAVITY LOADS TO BE RESISTED.
  
 6)- SBC 104.2.2 ADD INFO REQUIRED, SHEET
 A-3,A-4 & A-5 INFORMATIN ON THE CANTI-
 LEVERED TRUSS ASSEMBLY WITH 4" DROP.
  
 7)- MISSING IS A PRODUCT APPROVAL REPORT
 FOR THE SKYLIGHT, GLAZED OPENINGS RE-
 QUIRE LARGE MISSLE TESTING IF LOCATED
 LESS THAN 30' ABOVE GRADE. SBCCI OR DADE
 COUNTY REPORTS ARE ACCEPTED.
  
 8)- SBC 2309.6 ATTIC ACCESS FOR THE
 2ND FLOOR 22" X 36".
  
 9)- SBC 2309.7 SOFFIT VENTING INFO?
  
 10)- COUNTY IMPACT FEES
  
 11)- PERMIT APPLICATION GIVE THE SQUARE
 FOOTAGE OF ADDITION?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-09-25 Cont ID  
Sent By dpalmer Date 2001-09-25 Time 10:50 Rev Time 0.00
Received By dpalmer Date 2001-09-25 Time 10:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-20 Cont ID  
Sent By dpalmer Date 2001-08-20 Time 20:50 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 20:50 Sent To  
Notes
2001-08-20 00:00:00************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE THAT PERMIT APPLI-
 -CATION SAYS NEW BATHROOM AND BEDROOM???
 PLEASE NOTE THAT NOTHING WAS SUBMITTED
 FOR EITHER?
  
 2) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 3) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 4) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 5)NOTE: PLEASE NOTE LIGHTING FOR AHU.
  
 6)NOTE: PLEASE NOTE MISSING EGRESS
 LIGHTING FOR AHU`S. 210-70
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2002-01-04 Cont ID  
Sent By pkrauss Date 2002-01-04 Time 08:14 Rev Time 0.40
Received By pkrauss Date 2002-01-03 Time 10:07 Sent To  
Notes
2002-01-04 00:00:00 
 DENIED - THIS IS NOT A REVISION OR
 RESUBMITTAL.MECHANICAL WAS TAKEN OUT
 OF ORIGINAL SUBMITTAL.CONTRACTOR NEEDS
 TO FILL OUT PERMIT APPLICATION.
  
 FEES TO BE ADJUSTED BY DEAN RUNNELS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-10-17 Cont ID  
Sent By pkrauss Date 2001-09-26 Time 13:28 Rev Time 0.45
Received By tjonseck Date 2001-09-26 Time 13:28 Sent To  
Notes
2001-09-26 00:00:00 
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 2 COPIES OF ENERGY CALCS WHERE SUBMITTED
 BUT NOT HVAC SIZING IN ACCORDANCE WITH
 MANUAL J AS PER FLA ENERGY CODE
 607.1.ABC.1.
  
 PLEASE INIDICATE EXISTING UNIT WILL
 HANDLE THE LOAD OF THE ADDITIONAL SPACE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-20 Cont ID  
Sent By pkrauss Date 2001-08-20 Time 10:36 Rev Time 0.40
Received By pkrauss Date 2001-08-20 Time 10:36 Sent To  
Notes
2001-08-20 00:00:00*******************DENIED***************
  
 MECHANICAL PERMIT 01071020.
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE SUBMIT PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 PLEASE SUBMIT 2 SETS OF ENERGY CALCS &
 HVAC SIZING IN ACCORDANCE WITH MANUAL J
 AS PER FLA ENGERY CODE 607.1.ABC.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-20 Cont ID  
Sent By kstevens Date 2001-09-20 Time 17:51 Rev Time 0.33
Received By kstevens Date 2001-09-20 Time 17:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-13 Cont ID  
Sent By kstevens Date 2001-08-13 Time 14:44 Rev Time 0.50
Received By kstevens Date 2001-08-13 Time 14:44 Sent To  
Notes
2001-08-13 00:00:00DENIED
  
 1) SHOW WHERE WASHER AND WATER HEATER
 ARE TO BE LOCATED OR WHERE THEY ARE BE-
 ING RELOCATED FROM.
  
 2) SUBMIT SANITARY RISER DIAGRAM SHOWING
 RELOCATED WASHER AND NEW BATHROOM WITH
 PIPE SIZES AND VENTING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-25 Cont ID  
Sent By sgraham Date 2001-07-25 Time 11:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***