| Plan Review Stops For Permit 01071019 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-14 |
Time |
09:35 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-14 00:00:00 | TRUSS PLANS 11/14/01 JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-03 |
Time |
06:52 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2001-10-03 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2001-10-03 00:00:00 | PAY IMPACT FEES & RADON FEES 10/3/01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-27 |
Time |
16:35 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2001-08-27 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2001-08-27 00:00:00 | BUILDING PLAN REVIEW: | | | PERMIT: 01071019 | | | ADDRESS: 9042 LAKES BLVD | | | CONT: STATHIS CONSTRUCTION | | | TEL: (954) 275-1337 | | | | | | 1)- SHEET A-3 DETAIL #3, ADD. INFO. RE- | | | QUIRED. IS THIS A EXISTING COLUMN OR A | | | NEW COLUMN? LOADS IMPOSED? A FOUNDATION | | | REQUIRED? | | | | | | 2)- SHEET A-6 SHOWS A COLUMN WITH A MID- | | | POINT BEARING POINT, WHERE IS THIS APPLI | | | CATION USED? THIS SAME DETAIL REFRENCES | | | (3) USES, A SINGGLE, DOUBLE & TRIPLE | | | MEMBER TRUSS? | | | | | | 3)- SHEET A-6 DETAIL #22 NOTES THAT | | | 1X2, 1X4 BUCKS WILL BE ATTACHED WITH "T" | | | NAILS NO LENGTH IS GIVEN FOR THE NAIL | | | OR MINIMUM EMBEDMENT. | | | | | | 4)- A-6 DETAIL"A" NO INSILATION INFOR. | | | IS GIVEN FOR ABOVE THE GARAGE CEILING. | | | | | | 5)- SBC 104.2.2 ADD INFO. REQUIRED MISS- | | | ING THE 2ND STORY ROOF FRAMING PLAN, | | | TRUSS, GIRDER LOADS,VERTICAL / HORIZONT- | | | AL AND GRAVITY LOADS TO BE RESISTED. | | | | | | 6)- SBC 104.2.2 ADD INFO REQUIRED, SHEET | | | A-3,A-4 & A-5 INFORMATIN ON THE CANTI- | | | LEVERED TRUSS ASSEMBLY WITH 4" DROP. | | | | | | 7)- MISSING IS A PRODUCT APPROVAL REPORT | | | FOR THE SKYLIGHT, GLAZED OPENINGS RE- | | | QUIRE LARGE MISSLE TESTING IF LOCATED | | | LESS THAN 30' ABOVE GRADE. SBCCI OR DADE | | | COUNTY REPORTS ARE ACCEPTED. | | | | | | 8)- SBC 2309.6 ATTIC ACCESS FOR THE | | | 2ND FLOOR 22" X 36". | | | | | | 9)- SBC 2309.7 SOFFIT VENTING INFO? | | | | | | 10)- COUNTY IMPACT FEES | | | | | | 11)- PERMIT APPLICATION GIVE THE SQUARE | | | FOOTAGE OF ADDITION? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-09-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-25 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-25 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-20 |
Time |
20:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-20 |
Time |
20:50 |
Sent To |
|
|
| Notes |
| 2001-08-20 00:00:00 | ************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE NOTE THAT PERMIT APPLI- | | | -CATION SAYS NEW BATHROOM AND BEDROOM??? | | | PLEASE NOTE THAT NOTHING WAS SUBMITTED | | | FOR EITHER? | | | | | | 2) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | | | | 3) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 4) PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. | | | | | | 5)NOTE: PLEASE NOTE LIGHTING FOR AHU. | | | | | | 6)NOTE: PLEASE NOTE MISSING EGRESS | | | LIGHTING FOR AHU`S. 210-70 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-04 |
Time |
08:14 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-01-03 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2002-01-04 00:00:00 | | | | DENIED - THIS IS NOT A REVISION OR | | | RESUBMITTAL.MECHANICAL WAS TAKEN OUT | | | OF ORIGINAL SUBMITTAL.CONTRACTOR NEEDS | | | TO FILL OUT PERMIT APPLICATION. | | | | | | FEES TO BE ADJUSTED BY DEAN RUNNELS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2001-10-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-26 |
Time |
13:28 |
Rev Time |
0.45 |
| Received By |
tjonseck |
Date |
2001-09-26 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2001-09-26 00:00:00 | | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 2 COPIES OF ENERGY CALCS WHERE SUBMITTED | | | BUT NOT HVAC SIZING IN ACCORDANCE WITH | | | MANUAL J AS PER FLA ENERGY CODE | | | 607.1.ABC.1. | | | | | | PLEASE INIDICATE EXISTING UNIT WILL | | | HANDLE THE LOAD OF THE ADDITIONAL SPACE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS 659-8096 EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-20 |
Time |
10:36 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-08-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2001-08-20 00:00:00 | *******************DENIED*************** | | | | | | MECHANICAL PERMIT 01071020. | | | | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.PLEASE SUBMIT PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | PLEASE SUBMIT 2 SETS OF ENERGY CALCS & | | | HVAC SIZING IN ACCORDANCE WITH MANUAL J | | | AS PER FLA ENGERY CODE 607.1.ABC.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-20 |
Time |
17:51 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-09-20 |
Time |
17:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-13 |
Time |
14:44 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-08-13 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2001-08-13 00:00:00 | DENIED | | | | | | 1) SHOW WHERE WASHER AND WATER HEATER | | | ARE TO BE LOCATED OR WHERE THEY ARE BE- | | | ING RELOCATED FROM. | | | | | | 2) SUBMIT SANITARY RISER DIAGRAM SHOWING | | | RELOCATED WASHER AND NEW BATHROOM WITH | | | PIPE SIZES AND VENTING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-07-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-07-25 |
Time |
11:20 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|