Plan Review Details - Permit 01070620
Plan Review Stops For Permit 01070620
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-22 Cont ID  
Sent By dpalmer Date 2001-07-22 Time 10:15 Rev Time 0.00
Received By dpalmer Date 2001-07-22 Time 10:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-10 Cont ID  
Sent By pkrauss Date 2001-08-10 Time 11:21 Rev Time 0.35
Received By pkrauss Date 2001-08-10 Time 11:08 Sent To  
Notes
2001-08-10 00:00:00MASTER PERMIT 01070666.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-07-19 Cont ID  
Sent By hmoser Date 2001-07-19 Time 19:56 Rev Time 0.33
Received By hmoser Date 2001-07-19 Time 19:56 Sent To  
Notes
2001-07-19 00:00:00 
 #1ENERGY CALCS SHOW HEATRECOVERY
 UNIOT. HEATRECOVERY UNIOT IS
 NOT NO PLANS

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-18 Cont ID  
Sent By jleech Date 2001-07-18 Time 18:04 Rev Time 0.25
Received By jleech Date 2001-07-18 Time 18:04 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-15 Cont ID  
Sent By rmcdouga Date 2001-08-15 Time 15:44 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-04 Cont ID  
Sent By rmcdouga Date 2001-08-04 Time 11:57 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-04 00:00:00*************BUILDING UNSAT*************
  
 1)STRUCTURE IS LOCATED IN AN "A8" FLOOD
 ZONE. A FLOOD ELEVATION CERTIFICATE
 WILL BE REQUIRED.
  
 2) SURVEY AND PLANS DO NOT CORRESPOND
 WITH EACH OTHER. SURVEY INDICATES A
 CATALINA MODEL AND PLANS ARE FOR A
 LAGUNA MODEL. SUBMITED CORRECTED SURVEY.
  
 3) DUE TO INCORRECT SURVEY, THE
 PERCENTAGE OF EXTERIOR OPENINGS ALLOWED
 BY 97 SBC TABLE 600 COULD NOT BE
 CALCULATED.
  
 4) THE PLANS HAVE AN EXTRA SHEET A-2.
 PLEASE REMOVE ONE OF THEM FROM EACH SET.
  
 5) THE WALL SECTION ON A-2 INDICATES A
 FOOTER WITH A 20" DEPTH THE FOOTER
 SCHEDULE ON A-1 GIVES FOOTER DEPTH AS
 18". PLEASE REVISE SO THAT PLANS ARE
 CONSISTENT.
  
 6) THE FOOTINGS FOR THE 10" COLUMNS AT
 THE ENTRY ARE INDICATED AS F-8
 MONOLITHIC PADS BUT APPEAR TO BE F-8A
 CONCRETE PADS. PLEASE CLARIFY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-17 Cont ID  
Sent By sgraham Date 2001-07-17 Time 10:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***