Plan Review Details - Permit 01070616
Plan Review Stops For Permit 01070616
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-31 Cont ID  
Sent By dpalmer Date 2001-07-31 Time 20:53 Rev Time 0.00
Received By dpalmer Date 2001-07-31 Time 20:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-21 Cont ID  
Sent By hmoser Date 2001-07-21 Time 11:34 Rev Time 0.33
Received By hmoser Date 2001-07-21 Time 11:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-10 Cont ID  
Sent By kstevens Date 2001-08-10 Time 10:24 Rev Time 0.50
Received By kstevens Date 2001-08-10 Time 10:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-18 Cont ID  
Sent By jleech Date 2001-07-18 Time 19:13 Rev Time 0.33
Received By jleech Date 2001-07-18 Time 19:13 Sent To  
Notes
2001-07-18 00:00:00DENIED;
 1.SANITARY RISER DIAGRAM REQUIRED.
  
 2.PLUMBING LINE DRAWING ON PAGE 1A IS
 NOT TO CODE. HORIZONTAL DRY VENTS NOT
 SIZED PROPERLY.
  
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 659-8096 EXT 8369

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-01-14 Cont ID  
Sent By rmcdouga Date 2002-01-14 Time 10:01 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-01-14 00:00:00TRUSSES OK W/LETTER FROM ENGINEER

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-10-30 Cont ID  
Sent By rmcdouga Date 2001-10-30 Time 09:53 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-10-30 00:00:00TRUSSES UNSAT
 SAME COMMENTS AS 01070604. 10-30-01 RM

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-15 Cont ID  
Sent By rmcdouga Date 2001-08-15 Time 10:51 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-02 Cont ID  
Sent By rmcdouga Date 2001-08-02 Time 18:29 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-02 00:00:00*************BUILDING UNSAT*************
  
 1) STRUCTURE IS LOCATED IN AN "A8" FLOOD
 ZONE. A FLOOD ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 2) THE SURVEY DOES NOT CORRESPOND TO THE
 PLANS. PROVIDE SURVEY WITH CORRECT MODEL
 SHOWN ON LOT.
  
 3) WALL SECTION DETAIL ON SHEET A-2 HAS
 A 20" DEPTH FOOTER AND FOOTING SCHEDULE
 ON A-1 INDICATES AN 18" FOOTER DEPTH FOR
 F-1. PLEASE CORRECT.
  
 4) DUE TO INCORRECT SURVEY, PERCENTAGE
 OF ALLOWABLE WALL OPENINGS COULD NOT BE
 VERIFIED. (97 SBC TABLE 600)
  
 5) TRUSS ENGINEER TO BE SUPPLIED WITH
 INFORMATION ON A/C EQUIPMENT THAT IS
 BEING HUNG FROM TRUSSES TO INSURE THAT
 TRUSSES ARE DESIGN TO SUPPORT IMPOSED
 LOADS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-17 Cont ID  
Sent By sgraham Date 2001-07-17 Time 13:37 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***