| Plan Review Stops For Permit 01070374 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-29 |
Time |
22:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-29 |
Time |
22:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-17 |
Time |
21:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-17 |
Time |
21:15 |
Sent To |
|
|
| Notes |
| 2001-09-17 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT PLANS NOW | | | INCLUDE A RISER DIAGRAM WITH NEW EQUIP- | | | -MENT BEING INSTALLED. | | | PLEASE NOTE, NEED TO SUBMIT AIC RATINGS | | | FOR ALL NEW EQUIPMENT/MAIN/PANELS. | | | PER 110-9/215-5 | | | | | | 2)NOTE: PLEASE CLARIFY 10 GFI CIRCUITS | | | SHOWN ON PANEL SCHEDULE. PLEASE NOTE | | | THAT TWO SMALL APPLIANCE CIRCUITS ARE | | | REQ`D BY 210-52-B1 | | | | | | 3)NOTE: PLEASE LABEL GFI CIRCUIT FOR | | | BATH.210-11-C-3. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-02 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-02 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | ******************* UNSAT ************* | | | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | AND SHOW EXISTING SERVICE SIZE. | | | 220-3-C-1 | | | | | | 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210-8-A-6. | | | INCLUDING ISLAND. | | | | | | 3)NOTE" PLEASE PROVIDE PANEL SCHEDULE OF | | | MIN REQ`D CIRCUITS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-12-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-03 |
Time |
09:25 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-12-03 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2001-10-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-26 |
Time |
16:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-10-26 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2001-10-26 00:00:00 | *******************DENIED*************** | | | | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.PLEASE PROVIDE THE FOLLOWING IN | | | FORMATION FOR REVIEW. | | | | | | PROVIDE EQUIPMENT INFORMATION. | | | | | | DUCT SIZE, MATERIAL AND LAYOUT. | | | | | | GRILL SIZE AND LOCATION. | | | | | | CFM DISTRIBUTION. | | | | | | ENERGY CALCULATIONS WITH MANUAL J CALCS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-09-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-14 |
Time |
07:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-09-14 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2001-09-14 00:00:00 | ********************DENIED************** | | | | | | | | | PLEASE PROVIDE ENERGY CALCULATIONS AS | | | PER FLORIDA ENERGY CODE 101.2.2. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-08-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-07 |
Time |
07:55 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-08-07 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2001-08-07 00:00:00 | *******************DENIED*************** | | | INSUFFICIENT INFORMATION | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | WITH MECHANICAL PERMIT APPLICATION. | | | | | | 1.MAKE, MODEL, SEER, BTU, AND KW HEAT | | | STRIP FOR AHU/CONDENSER. | | | | | | 2.PROVIDE MATERIAL AND R-VALUE FOR | | | DUCT BEING INSTALLED. | | | | | | 3.SIZE OF GRILLS AND CFM BEING | | | DISTRIBUTED. | | | | | | 4.PLEASE PROVIDE ENERGY CALCULATIONS | | | TO SHOW COMPLIANCE WITH FLORIDA | | | ENERGY EFFICIENCY CODE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-12 |
Time |
19:47 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-09-12 |
Time |
19:47 |
Sent To |
|
|
| Notes |
| 2001-09-12 00:00:00 | SEPARATE GAS REQUIRED | | | IF ANY GAS WORK IS TO BE DONE.. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-06 |
Time |
08:57 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-08-06 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2001-08-06 00:00:00 | DENIED.. | | | | | | 1) NOT ENOUGH INFROMATION. | | | | | | 2) PLEASE SUBMIT A SANITARY RISER DIA- | | | GRAM SHOWING ALL NEW FIXTURES AND ANY | | | FIXTURES RELOCATED. | | | | | | 3) PLEASE SUBMIT DETAIL ON WATER AND | | | DRAINAGE FOR DISHWASHER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2002-01-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-01-30 |
Time |
16:13 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2002-01-30 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2002-01-30 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS UNDER A SEPARATE PERMIT. | | | 2-ELECTRICAL, PLUMBING AND MECHANICAL | | | WORK UNDER SEPARATE PERMITS SINCE THEY | | | DIDN'T SIGN ORIGINAL APPLICATION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2001-12-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-12-26 |
Time |
10:59 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2001-12-26 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2001-12-26 00:00:00 | 5TH CHECKLIST: | | | 1-PRODUCT APPROVAL INFORMATION SUBMITTED | | | STILL IS NOT ACCEPTABLE. | | | A)SITE SPECIFIC FORM NEEDS TO BE SIGNED, | | | SEALED & DATED BY ARCHITECT OF RECORD | | | AS WELL. | | | B)DESIGN PRESSURES SPECIFIED FOR THE | | | SLIDING GLASS DOORS ARE INCORRECT. | | | THOSE ARE THE RESULT PRESSURES, NOT | | | THE DESIGN PRESSURES. THEREFORE, THIS | | | PRODUCT APPROVAL IS NOT ACCEPTABLE. | | | SEE DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT OF RECORD. | | | C)PRODUCT APPROVAL IS FOR CASEMENT | | | WINDOWS.THERE ARE NOT CASEMENT WINDOWS | | | IN THIS PROJECT. SEE ARCHITECT'S PLANS | | | D)ENGINEER TO SEE ARCHITECT'S PLANS TO | | | SEE SIZES AND TYPE OF GLASS REQUIRED | | | ACCORDING TO LOCATION. (SAFETY GLASS | | | REQUIRED AT HAZARDOUS LOCATIONS. | | | SECTION2405.2 SBC 1997). | | | E)PROVIDE COMPLETE PRODUCT APPROVAL | | | INFORMATION FOR WINDOW MULLIONS. | | | | | | 2-OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS AS REQUIRED BY | | | SEC. 103.1 FLORIDA ENERGY EFFICIENCY | | | CODE FOR BUILDING CONSTRUCTION, 1997. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2001-12-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-12-06 |
Time |
15:28 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-12-06 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2001-12-06 00:00:00 | CHECKLIST: | | | 1-NEED ENERGY CALCULATIONS OF FORM | | | 600A-97. SEC. 101.2.2 FL. ENERGY CODE. | | | -INFORMATION SUBMITTED ARE THE MANUAL | | | J CALCS FOR A/C SIZING. | | | 2-COMMENTS FOR SITE SPECIFIC PRODUCT | | | APPROVAL INFORMATION SUBMITTED: | | | A)NEED TO COMPLETELY FILL OUT FORM FOR | | | SITE SPECIFIC INSTALLATIONS. SEE | | | ATTACHED COPY. | | | NOTE: THIS FORM TO BE SEALED, SIGNED & | | | DATED BY MANUFACTURER'S ENGINEER AND | | | BY ARCHITECT OF RECORD. | | | B)DESIGNED PRESSURES SPECIFIED FOR THE | | | SLIDING GLASS DOORS ARE TEST RESULTS, | | | NOT DESIGN PRESSURES. THEREFORE, THIS | | | PRODUCT APPROVAL IS NOT ACCEPTABLE. | | | -DESIGN PRESSURES MUST MEET OR EXCEED | | | THE DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT FOR THIS PROJECT. | | | C)THERE ARE NOT CASEMENT WINDOWS ON THIS | | | PROJECT. THERE ARE SINGLE HUNG WINDOWS | | | D)THERE IS NOT INFORMATION GIVEN FOR THE | | | FIXED WINDOWS. ALSO, CHECK SIZES SHOWN | | | ON ARCHITECT'S PLANS. | | | E)ENGINEER NEEDS TO PROVIDE ORIGINAL | | | SIGNATURE & DATE ON ALL DOCUMENTS | | | SUBMITTED FOR PUBLIC RECORDS AS REQ'D | | | BY CHAPTER 471 OF FLORIDA STATUTES. | | | | | | 3-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS. INFORMATION PROVIDED IS ONLY | | | THE PRODUCT APPROVAL. | | | -CLEARLY INDICATE ON DRAWINGS THE | | | SPECIFIC INSTALLATION FOR THIS PROJECT. | | | SAMPLE ATTACHED. SEE SHEET 2 OF 17. | | | NOTE: PROVIDE COMPLETE PRODUCT APPROVAL | | | REPORT. ONLY APPROVED DRAWINGS | | | WERE SUBMITTED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
N |
Date |
2001-11-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-11-02 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2001-11-02 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-11-02 |
Time |
14:30 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2001-11-02 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2001-11-02 00:00:00 | CHECKLIST: | | | 1-NEED ENERGY CALCULATIONS ON FORM | | | 600A-97 AS REQUIRED BY SECTION 101.2.2 | | | OF FLORIDA ENERGY EFFICIENCY CODE FOR | | | BUILDING CONSTRUCTION, 1997 EDITION. | | | -INFORMATION SUBMITTED ARE NOT THE | | | ENERGY CALCULATIONS. | | | 2-PROVIDE PRODUCT APPROVAL FOR: | | | A)SLIDING GLASS DOORS WITH SIZE AND | | | DESIGN PRESSURES AS SPECIFIED ON | | | ARCHITECT'S PLANS. | | | -PRODUCT APPROVAL SUBMITTED DOESN'T | | | MEET EITHER ONE. | | | C)FIXED WINDOWS WITH THE SIZE SHOWN IN | | | ARCHITECT'S PLANS. | | | -PRODUCT APPROVAL SUBMITTED IS FOR | | | WINDOWS UP TO 120" IN WIDTH AND UP TO | | | 60" IN HEIGHT. SEE ARCHITECT'S PLAN | | | FOR SIZE SPECIFIED. | | | 3-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS. | | | -CLEARLY INDICATE ON SHUTTER DRAWINGS | | | THE SPECIFIC MOUNTING CONDITIONS AND | | | ALL THE SPECIFIC COMPONENTS TO BE USED | | | ON THIS PROJECT. | | | -IF INFORMATION IS NOT COMPLETE AT THIS | | | TIME, THEN SUB-CONTRACTOR MAY APPLY | | | FOR A SEPARATE PERMIT IN ORDER TO | | | EXPEDITE THE BUILDING PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2001-09-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-09-24 |
Time |
19:07 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2001-09-24 |
Time |
19:07 |
Sent To |
|
|
| Notes |
| 2001-09-24 00:00:00 | CHECKLIST: | | | 1-NEED ENERGY CALCULATIONS AS REQUIRED | | | BY SECTION 101.2.2 OF STATE OF FLORIDA | | | ENERGY EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION, 1997 EDITION. | | | 2-CLARIFY HOW IS TRUSS ANCHOR TAPR | | | ANCHORED TO EXISTING TIE BEAM. | | | 3-SPECIFY SAFETY GLASS WHERE REQUIRED BY | | | SEC. 2405.2 SBC 1997. SEE PLANS. | | | 4-PROVIDE PRODUCT APPROVAL FOR: | | | A)FLAT ROOF SYSTEM TO BE USED. | | | B)SLIDING GLASS DOORS WITH THE SIZES AND | | | AND THE DESIGN PRESSURES AS SHOWN ON | | | THE ARCHITECT'S PLANS. | | | C)FIXED WINDOWS WITH THE SIZE AS SHOWN | | | ON ARCHITECT'S PLANS. | | | | | | 5-PROVIDE COMPLETE INFORMATION FOR STORM | | | PANELS:KEY PLAN, INSTALLATION SCHEDULE | | | AND CLEARLY INDICATE ON DRAWINGS THE | | | SPECIFIC MOUNTING CONDITIONS TO BE | | | USED. | | | -IF COMPLETE INFORMATION IS NOT | | | PROVIDE A TIME OF RESUBMITTAL, THEN A | | | SEPARATE PERMIT MAY BE APPLIED FOR. | | | 6-OWES ADDITIONAL FEES OF $315.28 FOR | | | UPDATED BUILDING VALUATION AND RADON | | | FEES. PLEASE PAY ATTACHED RECEIPT. | | | 7-SPECIFY FIREBLOCKING MATERIAL AND | | | LOCATION AS REQ'D BY SEC. 2305 SBC/97. | | | SEE SHEET #6 FOR COMMENTS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-07-31 |
Time |
11:01 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2001-07-31 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2001-07-31 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | BRING STAMPED DRAWINGS AND RECEIPT. | | | 2-NEED TO FILE NOTICE OF COMMENCEMENT. | | | 3-PROVIDE ENERGY CALCULATIONS. | | | 4-PROVIDE SOIL TEST REPORT. | | | 5-SPECIFY VENTILATION FOR ROOF AS REQ'D | | | BY SEC. 2309.7.2 SBC 1997. | | | 6-TRUSS ANCHOR SCHEDULE: | | | -CONNECTOR SEMCO RTPGA IS A WOOD TO | | | WOOD CONNECTOR. NOT WOOD TO CONCRETE. | | | REVISE AS REQUIRED. | | | -CLARIFY HOW IS CONNECTOR TAPR EMBEDED | | | INTO EXISTING TIE BEAM. | | | 7-REVISE THE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM. SEE | | | COMMENTS ON FORM. | | | 8-SPECIFY SAFETY GLASS WHERE REQUIRED. | | | SEC 2405.2 SBC/97. SEE FLOOR PLAN. | | | 9-NEED PRODUCT APPROVAL FOR: (2 COPIES) | | | -FLAT ROOF SYSTEM. | | | -CLAY BARREL TILE. | | | -SLIDING GLASS DOORS. | | | -SINGLE HUNG WINDOWS. | | | -FIXED WINDOWS. | | | 10-PROVIDE COMPLETE INFORMATION FOR | | | STORM PANELS. INSTALLATION SCHEDULE | | | KEY PLAN, ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-08-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-08-07 |
Time |
15:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|