Plan Review Details - Permit 01070173
Plan Review Stops For Permit 01070173
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-10-17 Cont ID  
Sent By jwitmer Date 2001-10-17 Time 13:55 Rev Time 3.00
Received By jwitmer Date 2001-10-17 Time 13:55 Sent To  
Notes
2001-10-17 00:00:00UPPED THE JOB VALUE JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2001-08-17 Cont ID  
Sent By hpiskura Date 2001-08-17 Time 09:55 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-08-02 Cont ID  
Sent By jwitmer Date 2001-08-02 Time 12:03 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By jwitmer Date 2001-07-25 Time 19:35 Rev Time 2.25
Received By jwitmer Date   Time   Sent To  
Notes
2001-07-25 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01070173
 CONT: CATALFUMO
 TEL: (561) 694-3000 X 256
 ARCH: ADA
 TEL: (561) 626-7381
  
 1)- STAIRWELL DOOR #2 SBC 4.12.8.1 EXITS
 ALL STAIRWELL DOORS WHICH ARE TO BE LOCK
 ED FROM THE STAIRWELL SIDE SHALL HAVE
 THE CAPACITY OF BEING UNLOCK SIMULTAN-
 EOUSLY WITHOUT UNLATCHING UPON A SIGNAL
 FROM THE CENTRAL CONTROL STATION. THE
 DOORS SHALL BE SIMILARLY UNLOCKED UPON
 ACTUATION OF THE SPRINKLER SYSTEM OR
 UPON POWER FAILURE.
 2)- COMMON CORRIDORS A & B SBC 704.2.1.4
 FIRE REATED WALLS, WALLS THAT REQUIRE
 PROTECTED OPENINGS SHALL HAVE SIGNAGE,
 " FIRE & SMOKE BARRIER PROTECT ALL OPEN-
 INGS".
 3)- SBC 609.2.1 TYPE I & TYPE II BUILD-
 INGS PARTITIONS SHALL BE CONSTRUCTED OF
 NONCOMBUSTIBLE MATERIAL, FIRE TREATED
 WOOD, ALL BACKING,BUCKS ETC
 4)- SBC 104.2.2* ADD INFORMATION
 REQUIRED: SHEET A-2 DETAIL 14 AND A-3
 DETAIL 4, SOFFITS ANCHORAGE TO CONCRETE
 DECK ABOVE,SPACING & TYPE OF ANCHOR?
 5)- SBC 1204.2 THE WALLS AND FLOOR OF
 ALL RESTROOMS SHALL BE LINED WITH NON-
 ABSORBANT MATERIALS TO A HEIGHT OF 4'-0"
 6)- PROGRAM SPECIALIST VI FL. ACCESSIBIL
 ITY CODE 1997: 4.13.6 MANEUVERING
 CLEARENCES AT DOORS REQUIRES A MINIMUM
 OF 18" SIDE WALL SPACE ON THE LATCH
 SIDE OF THE DOOR.
 7)- FL ACC CODE 4.5.1 FLOOR SURFACES
 ALONG ACCESSIBLE ROUTES AND IN ACCESS-
 IBLE ROOMS & SPACES INCLUDING FLOORS,
 WALKS, RAMPS & STAIRS SHALLBE FIRM &
 SLIP RESISTANT. ADDAAG A-5: A SLIP
 COEFFICIENT OF 0.6 IS RECCOMENDED FOR
 ACCESSIBLE ROUTES & 0.8 FOR RAMPS.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-12 Time 17:09 Rev Time 0.00
Received By dpalmer Date 2002-03-12 Time 17:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2002-02-20 Cont ID  
Sent By dpalmer Date 2002-02-20 Time 07:22 Rev Time 0.00
Received By dpalmer Date 2002-02-20 Time 07:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2001-12-10 Cont ID  
Sent By dpalmer Date 2001-12-10 Time 19:30 Rev Time 0.00
Received By dpalmer Date 2001-12-10 Time 19:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2001-10-30 Cont ID  
Sent By dpalmer Date 2001-10-30 Time 11:44 Rev Time 0.00
Received By dpalmer Date 2001-10-30 Time 11:44 Sent To  
Notes
2001-10-30 00:00:00*************** UNSAT **************
  
 1)NOTE:PLEASE NOTE THAT PLANS NEED TO
 SHOW A DETAIL/OR/LAYOUT.
  
 PLEASE SUBMIT FOR REVIEW.
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-10-10 Cont ID  
Sent By dpalmer Date 2001-10-10 Time 21:21 Rev Time 0.00
Received By dpalmer Date 2001-10-10 Time 21:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-09-10 Cont ID  
Sent By dpalmer Date 2001-09-10 Time 19:04 Rev Time 0.00
Received By dpalmer Date 2001-09-10 Time 19:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-20 Cont ID  
Sent By dpalmer Date 2001-08-20 Time 22:06 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 22:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-07-30 Cont ID  
Sent By dpalmer Date 2001-07-30 Time 19:34 Rev Time 0.00
Received By dpalmer Date 2001-07-30 Time 19:34 Sent To  
Notes
2001-07-30 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NOTE #13 FOR
 RISER NOTES ON E-3 READS PANELS W/ 125A
 MAIN BRKRS, WHICH IS REQ`D BY 384-16B.
 PLEASE NOTE THAT PANEL SCHEDULES ON E-4
 AND E-5 FOR "L1,L2 AND L3" READS "MLO"
 PLEASE NOTE THAT THIS IS LIKELY TO BE
 A MISPRINT BUT PLANS ARE COMING BACK FOR
 OTHER COMMNETS AND NEED TO BE CORRECTED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-08-16 Cont ID  
Sent By lsmith Date 2001-08-16 Time 12:37 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-12-11 Cont ID  
Sent By mcarsill Date 2001-12-11 Time 14:08 Rev Time 0.00
Received By mcarsill Date 2001-12-11 Time 14:08 Sent To  
Notes
2001-12-11 00:00:001) SECURITY FEATURES PLANNED FOR EXIT
 DOORS MUST COMPLY WITH NFPA 101, THE
 LIFE SAFETY CODE, 1985 EDITION,
 "SPECIAL LOCKING ARRANGEMENTS".
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-10-04 Cont ID  
Sent By mcarsill Date 2001-10-04 Time 10:42 Rev Time 0.00
Received By mcarsill Date 2001-10-04 Time 10:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-07-06 Cont ID  
Sent By mcarsill Date 2001-07-06 Time 10:47 Rev Time 0.00
Received By mcarsill Date 2001-07-06 Time 10:47 Sent To  
Notes
2001-07-06 00:00:00SECURITY FEATURES PLANNED FOR EXIT DOORS
 MUST COMPLY WITH NFPA 101, THE LIFE
 SAFETY CODE, 1985 EDITION, SPECIAL
 LOCKING ARRANGEMENTS. DOORS ARE TO BE
 FAIL SAFE AND NOT FAIL SECURE.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2001-12-19 Cont ID  
Sent By pkrauss Date 2001-12-19 Time 09:27 Rev Time 0.40
Received By pkrauss Date 2001-12-19 Time 09:27 Sent To  
Notes
2001-12-19 00:00:00*******************DENIED***************
  
  
 PLEASE SUBMIT 2 SEALED, SIGNED AND
 DATED COPIES OF ENGINEER LETTER ON
 CONDENSATE PUMP IN LIEU OF PIPING.
  
 SUBMIT MANUFACTURER SUBMITTAL DATA FOR
 THE CONDENSATE PUMP THAT IS TO BE
 INSTALLED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2001-12-14 Cont ID  
Sent By pkrauss Date 2001-12-14 Time 11:32 Rev Time 0.45
Received By pkrauss Date 2001-12-14 Time 11:32 Sent To  
Notes
2001-12-14 00:00:00REVISION SUBMITTED FOR PIPING ONLY (AS
 BUILT) BY HAWTHORNE...D. ROMCKE SEALED
 PLANS (NOT TITLE BLOCK)...OKAY PER LUIS
 MARTINEZ...

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-09-24 Cont ID  
Sent By pkrauss Date 2001-09-24 Time 12:46 Rev Time 0.35
Received By pkrauss Date 2001-09-24 Time 12:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-21 Cont ID  
Sent By pkrauss Date 2001-08-21 Time 09:56 Rev Time 0.50
Received By pkrauss Date 2001-08-21 Time 09:38 Sent To  
Notes
2001-08-21 00:00:00*******************PROVISO**************
  
  
 FIRE DAMPERS REQUIRED ON EXHAUST
 DUCTWORK PENETRATING FIRE RATED WALLS
 IN FILE ROOMS.PLEASE SUBMIT REVISED
 PLAN INDICATING FIRE DAMPERS FOR THESE
 PENTRATIONS.NOTE:DUCTWORK SHALL
 PENETRATE RATED WALL PERPENDICULAR SO
 FIRE DAMPER CAN BE INSTALLED PROPERLY.
  
 IF YOU HAVE ANY QUESTIONS PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-07-26 Cont ID  
Sent By pkrauss Date 2001-07-26 Time 11:25 Rev Time 1.20
Received By pkrauss Date 2001-07-26 Time 11:25 Sent To  
Notes
2001-07-26 00:00:00*******************DENIED***************
  
  
 HP-9, SUPPLY DUCTS FOR ROOMS MF12 AND
 EC6 REQUIRE FIRE DAMPERS WHERE DUCT
 PENETRATES THE FIRE RATED WALL.
  
 PLEASE PROVIDE AIR BALANCE SCHEDULE TO
 SHOW COMPLIANCE WITH 1997 SMC 501.2.
  
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8333.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-10-27 Cont ID  
Sent By kstevens Date 2001-10-27 Time 09:20 Rev Time 0.50
Received By kstevens Date 2001-10-27 Time 09:20 Sent To  
Notes
2001-10-27 00:00:00PASSED
  
 INCREASE OF FEES DUE FOR ADDITION OF
 PHASE II

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-10-16 Cont ID  
Sent By kstevens Date 2001-10-16 Time 10:39 Rev Time 0.50
Received By kstevens Date 2001-10-16 Time 10:39 Sent To  
Notes
2001-10-16 00:00:00DENIED
 REFERENCE: SPC-94 -
  
 WATER HAMMER ARRESTORS TO BE INSTALLED
 PER MANUFACTURE'S INSTALLATION INSTRUCT-
 IONS AND WH-PDI 201 NOT AT THE TOP OF
 DROP AS SHOWN BUT CLOSE TO SOURCE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-19 Cont ID  
Sent By jleech Date 2001-07-19 Time 09:24 Rev Time 1.50
Received By jleech Date 2001-07-19 Time 09:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2001-08-16 Cont ID  
Sent By lsmith Date 2001-08-16 Time 12:37 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***