Plan Review Details - Permit 01061475
| Plan Review Stops For Permit 01061475 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-10-24 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2001-10-24 |
Time |
16:00 |
Rev Time |
1.00 |
| Received By |
lhatten |
Date |
2001-10-24 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2001-10-24 00:00:00 | ASBUILT FOR INTERIOR RENOVATION AS WELL | | | AS ELEVATIONS PER HISTORIC PRESERVATION | | | 10/24/2001 | | | SAME AS ABOVE 10/24/2001 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2001-07-20 |
Time |
16:16 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-20 00:00:00 | OK PER TOM SUFFLIED TO PRINT PERMIT | | | 07/20/01 MM |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-19 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-19 |
Time |
10:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-11 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-11 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | ******** UNSAT ****** | | | | | | SEE REDLINES ON PLANS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-24 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-24 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2001-09-24 00:00:00 | PLANS ARE JUST NOW BEING SUBMITTED FOR | | | REVIEW. ELEC PERMIT WAS ISSUED IN ERROR | | | AS TURN AROUND WITH NO PLANS. | | | OWES AS REVISION, NOT A RE-STAMP. | | | PLANS WERE NEVER SUBMITTED FOR PLAN | | | REVIEW. PERMIT WAS ISSUED AS MISC | | | UNDER A PRE- INSPECT. PER TOM SUFF |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-23 |
Time |
14:33 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-23 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-19 |
Time |
10:03 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-17 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2001-10-17 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) RISER DIAGRAM NOT APPROVED. MANY | | | FIXTURES MISSING, BAR SINK 1ST FLOOR, | | | TUB, SHR, LAV, MASTER BATH, W/C, SHR, & | | | LAV 2ND BATH. BATH #3 NOT DRAWN CORRECT- | | | LY, SHOWS DRAINING UP TO CEILING. | | | PLEASE RESUBMIT SANITARY RISER DIAGRAM | | | THAT REFLECTS FLOOR PLAN AND HAS ALL | | | FIXTURES. PLEASE SHOW ALL PIPE SIZES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-11 |
Time |
15:04 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-11 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | DENIED | | | REFERENCE SPC-94 | | | | | | 1) PLEASE SUBMIT A SANITARY RISER DIA- | | | GRAM THAT REFLECTS THE FLOOR PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-07-20 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-07-20 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|