| Plan Review Stops For Permit 01061450 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-09-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-04 |
Time |
13:03 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2001-09-04 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-08-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-16 |
Time |
15:14 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2001-08-16 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2001-08-16 00:00:00 | BUILDING PLAN REVIEW | | | 1928 S DIXIE | | | | | | 1)- ALL COMMENTS ARE SATISFIED WITH EXCE | | | PTIONTO FIRE DISTRICT: | | | | | | TYPE VI CONSTRUCTION NOT ALLOWED IN FIRE | | | DISTRICT. APPEAL TO THE CBAA FOR A | | | VARIANCE . | | | | | | JIM WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-02 |
Time |
16:50 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2001-08-02 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01061450 | | | 1928 S DIXIE HWY | | | IRONWOOD PROPERTIES | | | 441-0222 | | | | | | SBC= STANDARD BUILDING CODE | | | | | | 1)- SBC F-102.1 FIRE DISTRICT RELOCATE | | | TO OUTSIDE FIRE DISTRICT AS PER CONVER- | | | SATION WITH L. MARTINEZ. | | | | | | 2)- SBC 104.2.2 ADDITIONAL INFORMATION | | | REQUIRED. DETAIL A CUT SECTION THROUGH | | | THE ENTRY WAY AND BRICK RAMP, TRAILER TO | | | BE SET 5" ABOVE GRADE (PER NOTE). | | | CODE REQUIREMENTS TO BE MET: | | | A) SBC 2304.3.4 FLOOR JOIST REQUIRE | | | 18" CLEARENCE FROM EARTH NOT P.T. | | | B) SBC 103.7 STATE TERMITE PROTEC- | | | TION CODE, ST. MEM.# 692 | | | 2.1- 6" CLEARENCE FROM GRADE, | | | WOOD PRODUCTS, | | | EXCEPTION: A 4" INSPSECTION SPACE | | | IS ACCEPTABLE AT PATIOS & SLABS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2001-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-12 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-12 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-04 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-04 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-08-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-15 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-15 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2001-08-15 00:00:00 | A CASE IS PLANNED TO BE HEARD IN FRONT | | | OF THE CBAA WITH REGARDS TO TYPE VI | | | CONSTRUCTION BEING LOCATED IN THE CITY | | | FIRE LIMITS. (AUGUST 22,2001) NO ACTION | | | CAN BE TAKEN AS THE PLANS REMAIN THE | | | SAME. MATTER MUST BE HEARD BEFORE THE | | | CBAA. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-02 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-02 |
Time |
19:47 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | PLEASE BE ADVISED THAT THE TRAILER | | | CANNOT BE LOCATED WITHIN THE CITY FIRE | | | LIMITS IF IT IS TYPE VI CONSTRUCTION. | | | CERTAIN RESTRICTIONS APPLY TO THE CITY | | | FIRE LIMITS. NO BULK FLAMMABLES OR | | | COMBUSTIBLE LIQUIDS OR BULK LP GAS ARE | | | PERMITTED TO BE STORED IN THE FIRE | | | LIMITS. THE TRAILER IF NON CONFORMING | | | CONSTRUCTION MUST BE LOCATED OUTSIDE | | | THE FIRE LIMITS. | | | | | | SMOKE DETECTORS AND A PORTABLE FIRE | | | EXTINGUISHER ARE REQUIRED. | | | | | | BUILDING ADDRESS REQUIRED PER CITY CODE | | | 3343-00. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-02 |
Time |
07:55 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-08-02 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-08-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-08-03 |
Time |
08:42 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-17 00:00:00 | PLUMBING PLAN REVIEWPROVISO: | | | COMPLY W/SPC-94 SEC 301.11.1 SANI SEWER | | | TO EXISTING. | | | SEC 301.11.2 WATER CONNECTION TO EXIST- | | | ING. | | | BACK FLOW PREVENTER REQ ON WATER SERVICE | | | TO TRAILER LOCAL ORDINANCE # 2853-95. | | | END OF COMMENTS PAUL SCHMTZ |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-07-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-07-10 |
Time |
07:28 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|