Plan Review Details - Permit 01061314
Plan Review Stops For Permit 01061314
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-01 Cont ID  
Sent By lmartine Date 2002-02-01 Time 11:57 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-07-11 Cont ID  
Sent By hpiskura Date 2001-07-11 Time 07:31 Rev Time 0.00
Received By hpiskura Date 2001-07-10 Time 13:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-24 Cont ID  
Sent By dpalmer Date 2002-05-24 Time 08:46 Rev Time 0.00
Received By dpalmer Date 2002-05-24 Time 08:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-12 Cont ID  
Sent By dpalmer Date 2001-07-12 Time 06:59 Rev Time 0.00
Received By dpalmer Date 2001-07-12 Time 06:59 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-07-05 Cont ID  
Sent By mamini Date 2001-07-05 Time 14:15 Rev Time 3.00
Received By mamini Date 2001-07-05 Time 14:14 Sent To  
Notes
2001-07-05 00:00:00PASSED WITH PROVISOS:
 1. AN APPROVED BACKFLOW PREVENTER IS
 REQUIRE AT ALL CROSS CONNECTIONS.
 2. ALL EXISTING CATCH BASINS MUST BE
 PROTECTED FOM DEBRIS AND SEDIMENTATION.
 3. ANY NEW CONNECTION TO CITY SERVICES
 WILL REQUIRE A SEPARATE PERMIT THROUGH
 PUBLIC UTILITIES ENGINEERING SERVICES
 DEPARTMENT. 659-8040
  
 IF ANY QUESTION PLEASE CONTACT659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2002-02-01 Cont ID  
Sent By mcarsill Date 2002-02-01 Time 13:28 Rev Time 0.00
Received By mcarsill Date 2002-02-01 Time 13:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-10-04 Cont ID  
Sent By mcarsill Date 2001-10-04 Time 14:52 Rev Time 0.00
Received By mcarsill Date 2001-10-04 Time 14:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-08-27 Cont ID  
Sent By mcarsill Date 2001-08-27 Time 15:01 Rev Time 0.00
Received By mcarsill Date 2001-08-27 Time 15:01 Sent To  
Notes
2001-08-27 00:00:001) PLEASE EXPLAIN ARRANGEMENT OF AN
 EMERGENCY STOP CONNECTED TO THE
 BUILDINGS FIRE ALARM SYSTEM. WHAT
 CODE ALLOWS THIS TO BE DONE. THE
 EMERGENCY STOP BUTTON CANNOT BE
 MONITORED BY THE BUILDINGS FIRE ALARM
 SYSTEM. PLEASE EXPLAIN AND PROVIDE
 CODE REFERENCE.
 2) PLANS HAVE NOT BEEN REVIEWED BY
 PBC DERM WITH REGARDS TO THE UNDEGROUND
 FUEL TANKS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-07-05 Cont ID  
Sent By mcarsill Date 2001-07-05 Time 18:25 Rev Time 0.00
Received By mcarsill Date 2001-07-05 Time 18:25 Sent To  
Notes
2001-07-05 00:00:001) UNDERGROUND FUEL TANKS TO COMPLY
 WITH NFPA 30, THE STANDARD FOR
 FLAMMABLE AND COMBUSTIBLE LIQUIDS
 CODE.
 2) COMPLIANCE IS REQUIRED WITH CITY
 CODE SECTIONS 11-70 AND 11-71 WITH
 REGARDS TO DEPTH OF COVERAGE OF FUEL
 TANKS AND VENT PIPES FOR THESE TANKS.
 3) FUEL DISPENSING HOSES SHALL BE LISTED
 AND BE NO LONGER THAN 18 FEET LONG.
 4) PLEASE INDICATE BREAKAWAY LOCATIONS.
 5) PLEASE INDICATE TYPES OF FIRE
 EXTINGUISHERS PLANNED FOR USE.
 6) PLEASE CLEARLY IDENTIFY DISTANCES
 FROM UNDERGROUND TANKS TO PROPERTY
 LINES AND ADJACENT BUILDINGS.
 7) ALL DISPENSING DEVICES ARE TO BE
 APPROVED FOR USE.
 8) PLEASE INDICATE THE DISTANCES
 BETWEEN THE UNDERGOUND FUEL TANKS.
 9) THE REMOVABLE SIGN TO INDICATE
 SITE SHOULD BE PERMANANT TO PREVENT
 VANDALISM OR THEFT.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2002-02-01 Cont ID  
Sent By pkrauss Date 2002-02-01 Time 13:36 Rev Time 0.40
Received By pkrauss Date 2002-02-01 Time 13:36 Sent To  
Notes
2002-02-01 00:00:00MASTER PLAN REVISED TO INDICATE
 ADDITIONAL UNDERGROUND TANK (3 TOTAL)
 AS PER FUEL PERMIT 02011241.NO HVAC
 FOR THIS PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-08-27 Cont ID  
Sent By pkrauss Date 2001-08-27 Time 14:03 Rev Time 0.40
Received By pkrauss Date 2001-08-27 Time 13:28 Sent To  
Notes
2001-08-27 00:00:00 
  
 PERMIT 01061314FOR BUILDING PERMIT
 ADDITIONAL PERMIT REQUIRED FOR FUEL.
  
  
 THIS PERMIT IS NOT APPROVAL FOR
 UNDERGROUND FUEL.ADDITIONAL PLANS
 WITH PALM BEACH CO. D.E.R.M. APPROVAL
 REQUIRED PRIOR TO ANY UNDERGROUND WORK
 BEING DONE.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-07-23 Cont ID  
Sent By pkrauss Date 2001-07-23 Time 13:25 Rev Time 0.50
Received By pkrauss Date 2001-07-23 Time 13:25 Sent To  
Notes
2001-07-23 00:00:00********************DENIED**************
  
  
 INSUFFICIENT INFORMATION PROVIDED FOR
 MECHANICAL REVIEW.PLEASE PROVIDE HVAC
 EQUIPMENT INFORMATION AND ANY EXHAUST
 INFORMATION FOR REVIEW.
  
 ADDITIONAL PERMIT REQUIRED FOR FUEL.
 PLEASE PROVIDE PLANS AND MAUFACTURER
 SUBMITTAL DATA WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-30 Cont ID  
Sent By kstevens Date 2001-08-30 Time 14:34 Rev Time 0.50
Received By kstevens Date 2001-08-30 Time 14:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-07 Cont ID  
Sent By jleech Date 2001-07-07 Time 11:51 Rev Time 2.00
Received By jleech Date 2001-07-07 Time 11:50 Sent To  
Notes
2001-07-07 00:00:00DENIED;
  
 1.COVER PAGE (CONSTRUCTION DATA).
 PLUMBING CODE SHOULD BE 1994 ADDITION
 OF THE STANDARD PLUMBING CODE.
  
 2.PAGE MEP 1 DIAGRAM #3 BALL VALVES ARE
 REQUIRED IN PLACE OF GATE VALVES.
  
 3.PAGE MEP 1 MEP NOTE #5 BACKFLOW
 PREVENTER NOT PERMITED TO BE INSTALLED
 IN ELECTRICAL ROOM.
  
 4.PAGE SPI NOTE 2.07 CONSTRUCTION WATER
 SHALL HAVE BACKFLOW PROTECTION.
  
 5.CANOPY;
 A.SHOW SQUIRE FOOTAGE AND CALCULATE
 RAINFALL FOR EACH GUTTER AND DOWN
 SPOUT.
 B. SIZE PER. CHAPTER 11 94 SPC.
 C.SHOW PIPING TO EXISTING STORM
 SEWER SYSTEM PER.1101.2
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-26 Cont ID  
Sent By sgraham Date 2001-07-26 Time 10:48 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***