Plan Review Details - Permit 01061214
Plan Review Stops For Permit 01061214
Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 17:54 Rev Time 0.25
Received By dpalmer Date 2003-02-27 Time 17:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-03-26 Cont ID  
Sent By btrobaug Date 2002-03-26 Time 07:10 Rev Time 0.00
Received By btrobaug Date 2002-03-26 Time 07:10 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-10-09 Cont ID  
Sent By dpalmer Date 2001-10-09 Time 08:57 Rev Time 0.00
Received By dpalmer Date 2001-10-09 Time 08:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-09-18 Cont ID  
Sent By dpalmer Date 2001-09-18 Time 22:41 Rev Time 0.00
Received By dpalmer Date 2001-09-18 Time 22:36 Sent To  
Notes
2001-09-19 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT A COMPLETE NEW
 RISER DIGRAM IS NOW BEING SUBMITTED FOR
 REVIEW.
 PLEASE NOTE THAT PLANS SHOW A MAIN DISC-
 -ONNECT IN FRONT OF FPL`S METERING??
 THIS IS NOT PERMITTED.PER FPL.
 PLEASE ALSO NOTE THAT PER ZONING, ONLY
 ONE METER CAN BE INSTALLED FOR RESIDENCE
 A GUEST HOUSE IS PERMITTED BUT NOT A
 SECOND METER, IN SF-14 AREA.(SINGLE FAM)
  
  
 2)NOTE: PLEASE ALSO NOTE THAT NOT ALL
 NOTES FROM FIRST REVIEW WERE ADDRESSED.
  
 3)NOTEL PLEASE NOTE MISSING OUTLETS FOR
 KITCHEN COUNTER-SPACE PER 210-52-C-1,2,3
 ,4,5.
  
 4) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 5)NOTE:PLEASE NOTE THAT NEW SERVICE CAN
 BE LOCATED ON "FUTURE" GUEST HOUSE BUT,
 PLANS SHOW NEW HOUSE PANEL HAVING NO
 MAIN?? PER 225-31.
  
 6) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IFTHERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
2001-09-18 00:00:00****************** UNSAT *************

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-07-17 Cont ID  
Sent By dpalmer Date 2001-07-17 Time 09:49 Rev Time 0.00
Received By dpalmer Date 2001-07-17 Time 09:49 Sent To  
Notes
2001-07-17 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
  
 3) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 4) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 MISSING DOWNSTAIRS.
  
 5) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50. AT DETACHED BLDG.
  
 6) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 7)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUNDING CONDUCTOR BETWEENHOUSE AND
 OTHER STRUCTURE. SIZE 250-122
  
 8)NOTE: PLEASE NOTE THAT PANEL AT NEW HO
 USE SHOWS MLO? PLEASE CLARIFY MEANS OF
 DISCONNECT FOR STRUCTURE PER 225-31&32
  
  
 9)NOTE: PLEASE NOTE THAT FEEDERS TO
 MAIN HOUSE SHOW 2# 0?? PLEASE CALRIFY
 WIRE SIZE. 0 DOES NOT CORRELATE TO ANY
 AWG.
  
 10)NOTE: PLEASE NOTE THAT PANEL SCHEDULE
 FOR EXISTING HOUSE DOES NOT SHOW BREAKER
 SIZE FEEDING NEW HOUSE. PLEASE CLARIFY
 150A ?? FEED TO HOUSE. PLEASE NOTE THAT
 EXSITING PANEL WILL MOST LIKELY NOT BE
 ABLE TO HOLD A 150A 2-P BRKR>??
 PLEASE CLARIFY.
  
 11)NOTE: PLEASE NOTE THAT PLANS SAY TO
 VERIFY SERVICE ENTRANCE CONDUCTORS?
 PLEASE NOTE THAT WE NEED TO KNOW WHAT
 SIZE EXSITING CONDUCTORS ARE. 215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW, IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-03-28 Cont ID  
Sent By hmoser Date 2002-03-28 Time 18:31 Rev Time 0.33
Received By hmoser Date 2002-03-28 Time 18:30 Sent To  
Notes
2002-03-28 00:00:00PROVISO
 NEED SIZE AND LOCATION OF RETURN AIR
 NEED LOCATION OF A/C CONDENSOR
 REFER TO FLORIDA BULDING CODE 2001
 PLAN REVIEW BY HAROLD MOSER 3/28/02

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-10-05 Cont ID  
Sent By btrobaug Date 2002-03-26 Time 07:11 Rev Time 0.40
Received By pkrauss Date 2001-10-05 Time 16:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-13 Cont ID  
Sent By pkrauss Date 2001-09-13 Time 15:15 Rev Time 0.40
Received By pkrauss Date 2001-09-13 Time 14:49 Sent To  
Notes
2001-09-13 00:00:00*******************PROVISO**************
  
 NO DRYER EXHAUST INDICATED ON PLAN.
 DRYER EXHAUST DUCT SHALL BE A MINIMUM
 OF 4" AND A MINIMUM OF 30 GAUGE
 GALVENIZED STEEL OR OTHER
 NONCOMBUSTIBLE MATERIAL OF EQUIVALENT
 STRENGTH & CORROSION RESISTANCE.THE
 WALL OR ROOF CAP SHALL BE NONSCREENED
 WITH A BACKDRAFT DAMPER.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-07-14 Cont ID  
Sent By hmoser Date 2001-07-14 Time 08:34 Rev Time 0.33
Received By hmoser Date 2001-07-14 Time 08:34 Sent To  
Notes
2001-07-14 00:00:00 
  
  
 #1
 NO ENERGY CALC.
 #2
 CHECK DUCT SIZE OR C.F.M.
 GREAT ROOM AND BEDROOM 3

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-18 Cont ID  
Sent By kstevens Date 2001-09-18 Time 13:59 Rev Time 0.33
Received By kstevens Date 2001-09-18 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-03 Cont ID  
Sent By kstevens Date 2001-07-03 Time 07:45 Rev Time 0.33
Received By kstevens Date 2001-07-03 Time 07:45 Sent To  
Notes
2001-07-03 00:00:00FAILED
  
 SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. WATER CLOSET WASHES
 PAST AN UNVENTED SHOWER. PLEASE SUBMIT A
 RISER DIAGRAM THAT MEETS CODE REQUIRE-
 MENTS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2002-04-04 Cont ID  
Sent By jgomez Date 2002-04-04 Time 17:09 Rev Time 0.33
Received By jgomez Date 2002-04-04 Time 17:09 Sent To  
Notes
2002-04-04 00:00:00REVISION APPROVAL.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2002-04-02 Cont ID  
Sent By jgomez Date 2002-04-01 Time 18:53 Rev Time 0.50
Received By jgomez Date 2002-04-02 Time 12:11 Sent To  
Notes
2002-04-02 00:00:00REVISION CHECKLIST:
 1-SPECIFY NAME OF ROOM AT SECOND FLOOR.
 IS IT GOING TO BE BEDROOM #2 OR IT
 WILL HAVE ANOTHER FUNCTION.
 2-IF BEDROOM #2, THEN SPECIFY EGRESS
 WINDOW SIZE AND TYPE TO COMPLY WITH
 SECTION 1005.4 SBC 1997.
 3-IF ROOM IS TO BE USED FOR ANOTHER
 PURPOSE OTHER THAN SLEEPING, THEN,
 SPECIFY ON PLANS UNDER THE NAME OF THE
 ROOM THAT SUCH ROOM NOT TO BE USED FOR
 SLEEPING PURPOSE (AS PER BUILDING
 OFFICIAL REQUIREMENTS
 4-CLARIFY SIZE AND TYPE OF WINDOW AT
 NORTH WEST SIDE OF BEDRROOM #2,
 -CHECK FOR EGRESS.
 5-SPECIFY SAFETY GLASS WHERE REQUIRED.
 - SEE PLANS.
  
 6-PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 10-03-02.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-10-03 Cont ID  
Sent By jgomez Date 2001-10-03 Time 18:39 Rev Time 2.00
Received By jgomez Date 2001-10-03 Time 18:39 Sent To  
Notes
2001-10-03 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
 2-PROVIDE PRODUCT APPROVAL FOR:
 A)CASEMENT WINDOWS.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)FRENCH DOOR WITH TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 D)METAL ROOFING.
 E)SPANISH "S" CONCRETE TILE.
 F)HALF CIRCLE WINDOWS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-09-21 Cont ID  
Sent By jgomez Date 2001-09-21 Time 14:46 Rev Time 3.00
Received By jgomez Date 2001-09-21 Time 14:46 Sent To  
Notes
2001-09-21 00:00:00CHECKLIST:
 1-NEED TO RECORD NOTICE OF COMMENCEMENT.
 2-UTILITY ROOM STAIRS NEED A LANDING.
 SEC. 1012.1.6 SBC 1997.
 3-SPECIFY SAFETY GLASS AT BEDROOM #2.
 SEE PLANS. SEC. 2405.2 SBC 1997.
 4-CLARIFY WHICH ONE IS THE EGRESS WINDOW
 FROM BEDROOM #2 THAT COMPLY WITH SEC.
 1005.4 SBC 1997. IF IT IS THE ONE AT
 LEFT SIDE OF ROOM, THEN, WHY IS THERE
 A MULLION SHOWN IN THE MIDDLE?.
 PROVIDE SIZES OF WINDOWS TO VERIFY
 CLEAR DIMENSIONS.
 5-SPECIFY SIZE OF ATTIC VENTS TO VERIFY
 COMPLIANCE WITH SEC. 2309.7 SBC 1997.
 6-TRUSS CONNECTOR SPECIFIED LSTA IS A
 WOOD TO WOOD CONNECTOR, NOT A WOOD TO
 MASONRY CONNECTOR. REVISE AS REQUIRED.
 SPECIFY CONNECTOR THAT WILL RESIST THE
 LATERAL LOADS AS WELL.
 7-PROVIDE COMPLETE CONSTRUCTION DETAILS
 FOR BAY WINDOW. SPECIFY SIZE AND TYPE
 OF COLUMNS. FASTENERS OF COLUMNS: TOP
 AND BOTTOM. SPECIFY CONNECTORS FOR
 WOOD LINTELS AT THE ENDS AND TO THE
 COLUMNS.
 8-OWES $203.07 FOR UPDATED CONSTRUCTION
 VALUE AND RADON FEES. PAY ATTACHED
 RECEIPT AND BRING PAID RECEIPT.
  
  
 NOTES:
 A-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS AT TIME OF RESUBMITTAL OR APPLY
 FOR SEPARATE PERMIT.
 B-PROVIDE MISSING PRODUCT APPROVALS AT
 TIME OF RESUBMITTAL OR BEFORE INSTALL-
 ATION IF TIME IS NEED IT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-26 Cont ID  
Sent By jgomez Date 2001-07-26 Time 11:05 Rev Time 3.50
Received By jgomez Date 2001-07-26 Time 11:05 Sent To  
Notes
2001-07-26 00:00:00CHECKLIST:
 1-AFTER ORIGINALS DRAWINGS ARE REVISED,
 PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT.
 3-PROVIDE ENERGY CALCULATIONS AND OWNER
 TO SIGN AND DATE THEM AS WELL.
 4-ARCHITECT TO FILL THE DESIGN CERTIFICA
 TION FOR BUILDING CODE COMPLIANCE FORM
 ATTACHED.
 5-A)STEPS AT FRONT ENTRY NEED RAILING.
 SECTION 1007.5 SBC 1997.
 B)UTILITY ROOM STAIRS NEED A LANDING AND
 RAILING. SEC 1012.1.6 & 1007.5 SBC/97.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC 2405.2 SBC 1997.
 7-EGRESS WINDOW AT BEDROOM #2 NEED TO
 COMPLY WITH SECTION 1005.4 SBC 1997.
 8-PROVIDE SOIL TEST REPORT FOLLOWING
 THE REQUIREMENTS OF SEC. 1804.2.7 OF
 CITY AMENDMENTS TO SBC 1997.
 9-REVISE NOTES IN FOUNDATION PLAN AND
 FOOTING TO BE 12" MINIMUM BELOW FINISH
 GRADE. SEE SECTIONS 1804.2.1 AND SEC
 1804.1.3 SBC 1997.
 10-SPECIFY DRAFSTOPPING LOCATION AND
 MATERIAL ON SECOND FLOOR FRAMING PLAN.
 SECTION 2305.2 SBC 1997.
 11-REVISE RIGHT ELEVATION AS REQUIRED TO
 MEET REQUIREMENTS OF TABLE 600 SBC/97.
 THE AMOUNT OF OPENINGS AT FIRST FLOOR
 EXCEED THE AMOUNT ALLOWED BY TABLE 600
 12-PROVIDE STRUCTURAL BUCK DETAILS FOR
 EXTERIOR DOORS AND WINDOWS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 13-PROVIDE COMPLETE FRAMING DETAIL FOR
 SKYLIGHT. SEC. 104.2.2 CITY AMENDMENTS
 14-PROVIDE FRAMING DETAILS FOR ARCHED
 OPENINGS. SEC. 104.2.2 CITY AMENDMENTS
 15-PROVIDE COMPLETE DETAIL/SECTION THRU
 STEEL COLUMN AT REAR PORCH. SPECIFY
 CONNECTORS TOP AND BOTTOM. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 16-PROVIDE SMOKE DETECTORS AT EACH STORY
 AS REQUIRED BY SEC 905.2.2 SBC 1997.
 17-PROVIDE TWO COPIES OF PRODUCT
 APPROVALS FOR:
 A)ENTRY DOOR AS SHOWN ON EXT. ELEVATION.
 B)SKYLIGHT (NEED TWO COPIES).
 C)WINDOW MULLIONS (IS EXPIRED).
 D)METAL ROOFING (AT BAY WINDOW).
 E)SPANISH "S" CONCRETE TILE.
 F)HALF CIRCLE WINDOWS.
 G)CASEMENT WINDOWS (EXPIRED)
 H)FRENCH DOORS (NEED TWO COPIES).
  
 18-STORM SHUTTERS:
 A)PROVIDE 2 COPIES OF PRODUCT APPROVAL.
 B)PROVIDE A KEY PLAN AND A COMPLETE
 INSTALLATION SCHEDULE (SAMPLE ATTACHED
 C)CLEARLY INDICATE ON STORM SHUTTERS
 DRAWINGS THE SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED ACCORDING TO THE MEAN ROOF
 HEIGHT, DESIGN PRESSURES, PANEL SPAN,
 EDGE DISTANCE, CONNECTION TYPE AND
 STRUCTURE TO BE ATTACHED TO (CONCRETE
 BLOCK OR CONCRETE)
  
 19-SEE COMMENTS BY THE OTHER TRADES AND
 ADDITIONAL COMMENTS ON THE PLANS AND
 PLEASE RETURN REVIEWED SET AFTER THE
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-02 Cont ID  
Sent By sgraham Date 2001-06-27 Time 10:06 Rev Time 0.00
Received By sgraham Date 2001-10-09 Time 13:16 Sent To  
Notes
2001-06-27 00:00:00NEED A SURVEY