| 2001-07-26 00:00:00 | CHECKLIST: |
| | 1-AFTER ORIGINALS DRAWINGS ARE REVISED, |
| | PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING STAMPED DRAWINGS AND RECEIPT. |
| | 2-NEED TO RECORD NOTICE OF COMMENCEMENT. |
| | 3-PROVIDE ENERGY CALCULATIONS AND OWNER |
| | TO SIGN AND DATE THEM AS WELL. |
| | 4-ARCHITECT TO FILL THE DESIGN CERTIFICA |
| | TION FOR BUILDING CODE COMPLIANCE FORM |
| | ATTACHED. |
| | 5-A)STEPS AT FRONT ENTRY NEED RAILING. |
| | SECTION 1007.5 SBC 1997. |
| | B)UTILITY ROOM STAIRS NEED A LANDING AND |
| | RAILING. SEC 1012.1.6 & 1007.5 SBC/97. |
| | 6-SPECIFY SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS AND SEC 2405.2 SBC 1997. |
| | 7-EGRESS WINDOW AT BEDROOM #2 NEED TO |
| | COMPLY WITH SECTION 1005.4 SBC 1997. |
| | 8-PROVIDE SOIL TEST REPORT FOLLOWING |
| | THE REQUIREMENTS OF SEC. 1804.2.7 OF |
| | CITY AMENDMENTS TO SBC 1997. |
| | 9-REVISE NOTES IN FOUNDATION PLAN AND |
| | FOOTING TO BE 12" MINIMUM BELOW FINISH |
| | GRADE. SEE SECTIONS 1804.2.1 AND SEC |
| | 1804.1.3 SBC 1997. |
| | 10-SPECIFY DRAFSTOPPING LOCATION AND |
| | MATERIAL ON SECOND FLOOR FRAMING PLAN. |
| | SECTION 2305.2 SBC 1997. |
| | 11-REVISE RIGHT ELEVATION AS REQUIRED TO |
| | MEET REQUIREMENTS OF TABLE 600 SBC/97. |
| | THE AMOUNT OF OPENINGS AT FIRST FLOOR |
| | EXCEED THE AMOUNT ALLOWED BY TABLE 600 |
| | 12-PROVIDE STRUCTURAL BUCK DETAILS FOR |
| | EXTERIOR DOORS AND WINDOWS. SECTION |
| | 104.2.2 CITY AMENDMENTS TO SBC 1997. |
| | 13-PROVIDE COMPLETE FRAMING DETAIL FOR |
| | SKYLIGHT. SEC. 104.2.2 CITY AMENDMENTS |
| | 14-PROVIDE FRAMING DETAILS FOR ARCHED |
| | OPENINGS. SEC. 104.2.2 CITY AMENDMENTS |
| | 15-PROVIDE COMPLETE DETAIL/SECTION THRU |
| | STEEL COLUMN AT REAR PORCH. SPECIFY |
| | CONNECTORS TOP AND BOTTOM. SECTION |
| | 104.2.2 CITY AMENDMENTS TO SBC 1997. |
| | 16-PROVIDE SMOKE DETECTORS AT EACH STORY |
| | AS REQUIRED BY SEC 905.2.2 SBC 1997. |
| | 17-PROVIDE TWO COPIES OF PRODUCT |
| | APPROVALS FOR: |
| | A)ENTRY DOOR AS SHOWN ON EXT. ELEVATION. |
| | B)SKYLIGHT (NEED TWO COPIES). |
| | C)WINDOW MULLIONS (IS EXPIRED). |
| | D)METAL ROOFING (AT BAY WINDOW). |
| | E)SPANISH "S" CONCRETE TILE. |
| | F)HALF CIRCLE WINDOWS. |
| | G)CASEMENT WINDOWS (EXPIRED) |
| | H)FRENCH DOORS (NEED TWO COPIES). |
| | |
| | 18-STORM SHUTTERS: |
| | A)PROVIDE 2 COPIES OF PRODUCT APPROVAL. |
| | B)PROVIDE A KEY PLAN AND A COMPLETE |
| | INSTALLATION SCHEDULE (SAMPLE ATTACHED |
| | C)CLEARLY INDICATE ON STORM SHUTTERS |
| | DRAWINGS THE SPECIFIC MOUNTING |
| | CONDITIONS AND ANCHOR TYPE AND SPACING |
| | TO BE USED ACCORDING TO THE MEAN ROOF |
| | HEIGHT, DESIGN PRESSURES, PANEL SPAN, |
| | EDGE DISTANCE, CONNECTION TYPE AND |
| | STRUCTURE TO BE ATTACHED TO (CONCRETE |
| | BLOCK OR CONCRETE) |
| | |
| | 19-SEE COMMENTS BY THE OTHER TRADES AND |
| | ADDITIONAL COMMENTS ON THE PLANS AND |
| | PLEASE RETURN REVIEWED SET AFTER THE |
| | CORRECTIONS ARE DONE TO THE ORIGINAL |
| | DRAWINGS IN ORDER TO EXPEDITE THE |
| | REVIEW PROCESS. |