| Plan Review Stops For Permit 01061173 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-03 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-03 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-08-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-08-15 |
Time |
19:38 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2001-08-15 |
Time |
19:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-07-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-06-25 |
Time |
19:10 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-06-25 |
Time |
19:10 |
Sent To |
|
|
| Notes |
| 2001-07-30 00:00:00 | PLANS DENIED | | | #1 PLANS ARE NOT STAMPED | | | PLAN REVIEW BY HAROLD MOSER | | | [561]659-8096 EXT 8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-09-22 |
Time |
11:46 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-09-22 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-26 |
Time |
10:49 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-06-26 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2001-06-26 00:00:00 | ...PROVISO... | | | | | | SEPARATION WALL REQUIRED TO KEEP FLAM- | | | ABLE MATERIAL AWAY FROM GAS W/HEATER | | | PER SGC-97 SEC 504.3 (IN CLOSET) |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
P |
Date |
2002-10-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-10-22 |
Time |
15:50 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-22 00:00:00 | SUBMITTAL FOR BUTT GLASS WITH LETTER | | | FROM ARCHITECT REVISING POSITIVE AND | | | NEGATIVE WINDLOAD PRESSURES FOR THE | | | OPENING IS OK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-10-17 |
Time |
17:28 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-17 00:00:00 | SUBMITTAL FOR BUTT GLASS DENIED. THE | | | LETTER FROM THE ARCHITECT STATES THAT | | | THE CALCULATIONS FOR THE REVISED WIND | | | LOAD PRESSURE AT THE BUTT GLASS WINDOW | | | IS ATTACHED. HOWEVER NO CALCULATIONS | | | WERE SUBMITTED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2002-10-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-10-10 |
Time |
17:29 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-10 00:00:00 | SUBMITTAL DENIED | | | | | | BUTT GLAZING | | | | | | 1) THE ENGINEERING FOR THE BUTT GLAZING | | | MUST BE REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD FOR THE STRUCTURE. | | | | | | 2) THE WIND PRESSURE AT THIS OPENING IS | | | GIVEN AS -48 AND +47 PSF ON SHEET A-5 OF | | | THE PLANS. THE PRODUCT ENGINEERING IS | | | ONLY GOOD FOR -34.2 AND +33.6 PSF. | | | | | | | | | FRONT DOORS | | | | | | 1) THE PRODUCT APPROVAL SUBMITTAL FORM | | | IS ILLEGIBLE. | | | | | | 2) THE ENGINEER'S SIGNATURE IS NOT | | | ORIGINAL. | | | | | | 3) THE ENGINEER'S NAME AND LICENSE | | | NUMBER SHOULD BE ON DOCUMENT AND BE | | | LEGIBLE. | | | | | | 4) INSTALLATION SITE LOCATION IS | | | REQUIRED TO BE ON THE FORM. | | | | | | 5) THE DESIGNER OF RECORD IS REQUIRED TO | | | REVIEW AND APPROVE THE INFORMATION AND | | | SIGN AND SEAL THE FORM. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-10-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-10-05 |
Time |
16:26 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-05 00:00:00 | REVISION OK W/PROVISO 10-5-01 RM | | | PROVISO | | | PROVIDE DETAIL DRAWING OF C13 STEEL | | | COLUMN. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-08-29 |
Time |
16:11 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-29 00:00:00 | ************BUILDING PROVISO************ | | | | | | 1) PROVIDE ENGINEERING FOR BUTT GLASS | | | ASSEMBLIES PER 1997 SBC 2406.2. | | | | | | 2)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - CASEMENT WINDOWS | | | - STRUCTURAL MULLIONS (DOOR & WINDOW | | | ASSEMBLIES) | | | | | | NOTE: ALL EXTERIOR GLAZING MUST BE | | | IMPACT RESISTANT OR A SEPARATE PERMIT | | | FOR STORM PANELS WILL BE REQUIRED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-07-27 |
Time |
11:14 |
Rev Time |
5.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-27 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROVIDE EGRESS WINDOW IN EXERCISE | | | ROOM, WHICH COULD BE USED AS A SLEEPING | | | ROOM. 97 SBC 1005.4 | | | | | | 3) PROVIDE ENGINEERING FOR BUTT GLASS | | | ASSEMBLIES PER 1997 SBC 2406.2. | | | | | | 4) PROVIDE AT LEAST ONE BATHROOM WITH A | | | DOOR THAT HAS A 29" CLEAR OPENING PER 97 | | | FLORIDA ACCESSIBILITY CODE 4.22.2. | | | | | | 5) PROVIDE ROOF FRAMING PLAN FOR CHIMNEY | | | INDICATING CONNECTORS THAT WILL BE USED | | | TO ANCHOR TRUSSES. | | | | | | 6) THE NAIL SPACING FOR ROOFS USING 8D | | | COMMON NAILS IN ZONE 3 IS 4" AT THE | | | EDGES AND 6" INTERMEDIATE PER CITY | | | AMENDMENTS TO THE 97 SBC SEC.2306. | | | PLEASE CORRECT SCHEDULE ON SHEET A-8. | | | | | | 7) PLEASE CLARIFY DETAIL AA-2 AND AA-3 | | | INDICATED ON SHEET A-7. THEY ARE NOT | | | SHOWN ON SHEET A-8. | | | | | | 8) SPECIFY THE CONNECTORS FOR ALL OF THE | | | TRUSSES NOT SPECIFICALLY INDICATED ON | | | SHEET A-7. | | | | | | 9)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - STRUCTURAL MULLIONS FOR WINDOW | | | ASSEMBLIES | | | - STRUCTURAL MULLIONS FOR DOOR WITH | | | TRANSOM ABOVE ASSEMBLIES | | | - CASEMENT WINDOWS | | | | | | NOTE: ALL EXTERIOR GLAZINGS TO BE IMPACT | | | GLASS OR STORM PANELS WILL BE REQUIRED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-06-25 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|