Plan Review Details - Permit 01060951
Plan Review Stops For Permit 01060951
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-08-10 Cont ID  
Sent By jwitmer Date 2001-08-10 Time 13:17 Rev Time 1.25
Received By jwitmer Date 2001-08-10 Time 13:17 Sent To  
Notes
2001-08-10 00:00:00NOTE: SBC 1010.3 EXCEPTION CODE COM-
 MENTARY FIGURE 1013.3B EXIT DISCHARGE
 AND COMMUNICATING AREAS SPRINKLERED JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-07-11 Cont ID  
Sent By jwitmer Date 2001-07-11 Time 08:28 Rev Time 8.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-07-11 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01060951
 700 S ROSEMARY AVE # 106
 CONT: DITOCCO KONSTRUCTION INC
 P: (954) 943-7708
 ARCH: EDMOND LE BANC
 P: (561) 585-3403
  
 SBC= STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
 1)- SBC* 104.2.2- WE WILL NEED TO KNOW
 THE OCCUPANCIES THAT ARE TO OCCUPY THE
 SECOND FLOOR, WE UNDERSTAND THAT THE
 TENANT SPACE 202-B4.C MAY BE A NIGHTCLUB
 AND THE TENANT SPACE 202 B4.BMAY BE SOME
 TYPE OF GYM.
  
 2)- TENANT SPACE 202 B4.B (4936 SQ FT)
 WILL REQUIRE (2) MEANS OF EGRESS,
 SBC 1004.2.1. 2 APPROVED INDEPENDANT
 EXITS, ACCESSIBLE TOEACH TENANT AREA
 SERVING EVERY STORY. THE MAIN STAIRWAY
 WOULD HAVE TO COMPLY WITH RATINGS FOR
 MINIMUM FIRE RESISTANCE (TABLE 705.1.2)
 FOR SHAFT ENCLOSURES. 1 HR FOR BUSINESS
 & MERCANTILE. 2HR. SHAFT RATING (NOTE 2)
 FOR ASSEMBLY, FIRST & SECOND FLOOR.SBC
 1006.1 ENCLOSED STAIRWAYS.705.2/T705.1.2
 3)- TENANT SPACE 202 B4.C THIS SPACE IF
 OCCUPIED BY AN ASSEMBLY OCCUPANCY WOULD
 ALSO REQUIRE A 2 HR TENANT SEPERATION AS
 NOTED ON THE PLANS. SBC 1019.1: THE
 MINIMUM AGGREATE WIDTH OF MAIN ENTRANCE
 DOORWAYS FOR GROUP A ASSEMBLY OCCUPANC-
 IES SHALL BE SUFFICIENT TO ACCOMODATE
 50% OF THE OCCUPANT LOAD. EACH LEVEL OF
 A, ASSEMBLY OCUPANCY SHALL HAVE ACCESS
 TO A MAIN EXIT AND SHALL BE PROVIDED
 WITH ADDITIONAL EXITS OF SUFFICIENT
 WIDTH TO ACCONIDATE 1/2 OF THE TOTAL
 OCCUPANT LOAD SERVED BY THAT LEVEL.
  
 THIS WOULD REQUIRE THE FRONT STAIRWAY TO
 HAVE A 2 HR RATING, 1 1/2 HR RATING ON
 OPENINGS WHICH IS MISSING ON THE EXIST-
 ING STAIRWELL DOOR.
  
 THERE SEEMS TO BE A PROBLEM WITH EXITING
 FOR THIS TENANT SPACE, UNDER ASSEMBLY
 OCCUPANCY. WHEN WE USE 15 SQ FT/ PERSON
 THERE IS A GREAT CONCERN IF THE STAIRS
 & DOORWAYS WILL HANDLE THE LOADING
 PLEASE SUBMITT A LIFE SAFETY PLAN FOR
 THE FIRST FLOOR & SECOND FLOOR SHOWING
 THE EXITING, THE REAL PROBLEM!!!! IS
 WHEN UNDER A NIGHTCLUB OCCUPANCY WE GO
 A MORE CONCENTRATED AREAS FOR DANCE
 FLOORS TO 7 SQ FT & 3 SQ FT FOR BARS.
 THE DESIGN DOESN'T BEGIN TO WORK FOR
 A CONSINTRATION AS THIS MAY BE.
  
 4)- SBC 1003.3.5 THE LIFE SAFETY PLAN
 NEEDS TO SHOW THE CONVERGING EXITS AND
 THE TENANT LOADS THROUGH TO THE EXTERIOR
 OF THE BUILDING.
  
 5)- SBC 104.2.2* ADDITIONAL INFORMATION
 SERVICE CORRIDOR 108: VERIFY THAT THERE
 IS A ACCESSIBLE RAMP WITH A HEIGTH TRANS
 ITION OF 1'-4"?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-11-08 Cont ID  
Sent By dpalmer Date 2001-11-08 Time 16:16 Rev Time 0.00
Received By dpalmer Date 2001-11-08 Time 16:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-08 Cont ID  
Sent By dpalmer Date 2001-08-08 Time 09:41 Rev Time 0.00
Received By dpalmer Date 2001-08-08 Time 09:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-07-02 Cont ID  
Sent By dpalmer Date 2001-07-02 Time 08:24 Rev Time 0.00
Received By dpalmer Date 2001-07-02 Time 08:24 Sent To  
Notes
2001-07-02 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT ANY HANDWRITTEN
 CHANGES ON PLANS ARE TO BE INITIALED AND
 DATED BY THE ARCH/AND OR ENGINEER OF
 RECORD. 471.025 AND 481.22 OF F.A.C
  
 2)NOTE: PLEASE NOTE THAT DUE TO COMMENTS
 FROM FIRE REVIEW. ELECTRICAL PLANS MAY
 BE CHANGED. PLEASE NOTE THAT ELECTRICAL
 WILL BE STAMPED AT THAT TIME.
  
 PLEASE ADDRESS COMMENT #1. IF THERE ARE
 ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-07-11 Cont ID  
Sent By jwitmer Date 2001-07-11 Time 08:28 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-08-14 Cont ID  
Sent By mcarsill Date 2001-08-14 Time 08:16 Rev Time 0.00
Received By mcarsill Date 2001-08-14 Time 08:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-06-22 Cont ID  
Sent By mcarsill Date 2001-06-22 Time 13:20 Rev Time 0.00
Received By mcarsill Date 2001-06-22 Time 13:20 Sent To  
Notes
2001-06-22 00:00:001) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS.
 2) ADDITIONAL ILLUMINATED EXIT SIGNS
 AND EMERGENCY LIGHTING EQUIPMENT APPEARS
 TO BE NEEDED.
 3) NEW ELEVATOR TO COMPLY WITH
 THE REQUIREMENTS OF ANSI A17.1.
 4) EXISTING STAIR SHAFT TO BE INSPECTED
 TO ENSURE MINIMUM CODE REQUIREMENTS
 HAVE BEEN MET.
 5) PROVIDE SEPARATE PLANS AND PERMITS
 FOR FIRE ALARM REMODEL.
 6) ALL NEW STAIRS TO COMPLY WITH NEW
 STAIR REQUIREMENTS OF NFPA 101, THE
 LIFE SAFETY CODE, 1985 EDITION.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-15 Cont ID  
Sent By pkrauss Date 2001-10-15 Time 11:26 Rev Time 0.45
Received By pkrauss Date 2001-10-08 Time 13:17 Sent To  
Notes
2001-10-15 00:00:00*******************PROVISO**************
  
  
 PLAN SHEET B-M1 DETAIL OF PARTIAL GROUND
 FLOOR PLAN - "B" BLOCK, 12" X 12" EXH.
 UP SHOULD THIS PENETRATION BE RATED A
 FIRE DAMPER WILL BE REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-06 Cont ID  
Sent By pkrauss Date 2001-06-29 Time 11:17 Rev Time 0.35
Received By pkrauss Date 2001-06-29 Time 11:17 Sent To  
Notes
2001-07-06 00:00:00SHELL ONLY - DIVIDING AREA INTO 3
 DIFFERENT TENANT SPACE.1 ON 1ST
 FLOOR, TWO ON 2ND FLOOR.
  
 INTERIOR BUILD OUT WILL HAVE SEPERATE
 PLANS AND PERMIT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-10-24 Cont ID  
Sent By kstevens Date 2001-10-24 Time 10:06 Rev Time 0.25
Received By kstevens Date 2001-10-24 Time 10:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-10-22 Cont ID  
Sent By kstevens Date 2001-10-22 Time 13:27 Rev Time 1.00
Received By kstevens Date 2001-10-22 Time 13:27 Sent To  
Notes
2001-10-22 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PERMIT NUMBER FOR ELEVATOR/ESCALATOR
 AREA NOT FOR TENANT SPACE THAT THIS
 PLUMBING IS FOR. NO PLUMBING PERMIT HAS
 NEVER BEEN ISSUED FOR TENANT BUILD OUT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-06 Cont ID  
Sent By kstevens Date 2001-07-06 Time 14:15 Rev Time 0.50
Received By kstevens Date 2001-07-06 Time 14:15 Sent To  
Notes
2001-07-06 00:00:00PASSED
  
 PROVISO
  
 1) VENT TO BE 3" TO SERVE TENNANT B4A.
 PAGE B-P1
  
 2) SEPARATE PLANS FOR TENNANT BUILD-OUT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2001-07-11 Cont ID  
Sent By jwitmer Date 2001-07-11 Time 08:27 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***