Plan Review Details - Permit 01060623
| Plan Review Stops For Permit 01060623 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-07-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-05 |
Time |
07:05 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-30 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-30 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-15 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-15 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2001-06-15 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | 1) | | | | | | 2)NOTE: PLEASE NOTE PLAN WERE NOT SUB- | | | -MITTED COMPLETE. NO LOAD CALCULATIONS, | | | NO SERVICE FEEDER SIZES, NO PANEL SCHEDU | | | LES THAT CORRELATE WITH BRANCH CIRCUITS | | | SHOWN ON PLANS. | | | 3) NOTE: PLEASE SHOW ALL CONTINUOUS AT | | | 125%. (LIGHTING ETC) | | | | | | 3)NOTE: PLEASE SHOW SIZES FOR ALL | | | EQUIPMENT. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REIVEW | | | 561-659-8099 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-06-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-06-20 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-06-20 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-06-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-29 |
Time |
09:13 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-06-29 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2001-06-29 00:00:00 | ******************PROVISO*************** | | | | | | | | | SHOULD ANY DUCT WORK BE REPLACED OR | | | ADDED, CALL FOR AN INSPECTION PRIOR TO | | | CONNECTING TO ANY EXISTING DUCT WORK. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-06-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-06-30 |
Time |
07:35 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-06-30 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2001-06-30 00:00:00 | BATHROOM TO REMAIN AS IS. |
|
|
|