Plan Review Details - Permit 01060525
Plan Review Stops For Permit 01060525
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-15 Cont ID  
Sent By dpalmer Date 2001-06-15 Time 06:53 Rev Time 0.00
Received By dpalmer Date 2001-06-15 Time 06:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-19 Cont ID  
Sent By hmoser Date 2001-06-19 Time 17:49 Rev Time 0.33
Received By hmoser Date 2001-06-19 Time 17:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-11-06 Cont ID  
Sent By kstevens Date 2001-11-06 Time 14:55 Rev Time 0.50
Received By kstevens Date 2001-11-06 Time 14:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-07-19 Cont ID  
Sent By rmcdouga Date 2001-07-19 Time 09:44 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-16 Cont ID  
Sent By jleech Date 2001-07-16 Time 18:43 Rev Time 0.33
Received By jleech Date 2001-07-16 Time 18:42 Sent To  
Notes
2001-07-16 00:00:00PROVISO; REVISED RISER DIAGRAM REQUIRED
 BEFORE FINAL INSPECTION. RISER DIAGRAM
 TO REFLECT FLOOR PLAN.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-14 Cont ID  
Sent By kstevens Date 2001-06-14 Time 09:52 Rev Time 0.33
Received By kstevens Date 2001-06-14 Time 09:52 Sent To  
Notes
2001-06-14 00:00:00REVIEW NOTES: FAILED
  
 PLEASE SUBMIT A SANITARY RISER DIAGRAM
 THAT REFLECTS THE FLOOR PLAN.
 SPC-94104.2.1 & 104.3.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-08-01 Cont ID  
Sent By rmcdouga Date 2001-08-01 Time 16:36 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-01 00:00:00TRUSSES OK 8-1-01 RM

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-07-19 Cont ID  
Sent By rmcdouga Date 2001-07-19 Time 10:02 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-19 00:00:00TRUSSES
 UNSAT
  
 1) TRUSS DRAWINGS AND LAYOUT MUST BE
 REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD FOR THE STRUCTURE. IF ACCEPTABLE
 TO THE DESIGNER OF RECORD THE TRUSS
 LAYOUT SHOULD BE SIGNED AND SEALED BY
 HIM IN ADDITION TO THE TRUSS ENGINEER.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-07-18 Cont ID  
Sent By rmcdouga Date 2001-07-18 Time 19:34 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-06-29 Cont ID  
Sent By rmcdouga Date 2001-06-29 Time 18:36 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-06-29 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATED IN AN "A" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 3) THE ROOF FRAMING PLAN LOCATED ON
 SHEET 3 IS A REVERSE OF THE OTHER
 DRAWINGS SUBMITTED. PLEASE CORRECT.
  
 4) DETAIL A ON SHEET 3 IS NOT SHOWN.
  
 5) PROVIDE DETAIL OF THE CANTILEVERED
 CONCRETE BEAM REINFORCEMENT AT THE LANAI
  
 TRUSSES
 UNSAT
  
 1) THE MEAN ROOF HEIGHT GIVEN ON THE
 TRUSS DRAWINGS IS NOT CONSISTENT. PLEASE
 CORRECT. MEAN ROOF HEIGHT OF THE
 STRUCTURE IS 15FT.
  
 2) DESIGN CRITERIA ON PLANS LISTS 97
 SBCCI, THE ORGANIZATION AND NOT THE 97
 SBC, THE CODE. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-02 Cont ID  
Sent By sgraham Date 2001-07-02 Time 09:54 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***