| Plan Review Stops For Permit 01051470 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-11-15 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-11-15 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2004-11-15 00:00:00 | UPDATED GARAGE DOOR PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-11-03 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2004-11-03 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
| 2004-11-03 00:00:00 | CHECKLIST: | | | 1-PRODUCT APPROVAL SUBMITTAL SUBMITTED | | | FOR GARAGE DOOR WAS EXPIRED OVER A | | | YEAR AGO(8-14-03). NEED CURRENT | | | PRODUCT APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-30 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-30 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | REVISED RISER ONLY ON FULL SHEET. | | | REDLINED 60A FEED FOR PANEL "D". |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2003-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-24 |
Time |
06:00 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-01-24 |
Time |
06:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2003-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-07 |
Time |
16:46 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-01-07 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2003-01-07 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE RISER DIAGRAM AND | | | PANEL SCHEDULE NEED TO CORRELATE. | | | PLEASE SHOW SIZES OF PANELS AND MATCH | | | UP WITH RISER.("D"). | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULES AND | | | CORRELATE WIRE/PANELS/OCP. NOTE 200A | | | BRKR ON #3AWG. PLEASE ALSO SEE SOME | | | OTHER WIRE SIZES TOO SMALL FOR OCP. | | | | | | 3)NOTE: PLEASE NOTE AHU #1 SHOWN W/ #8 | | | AWG. PLEASE NOTE WIRE IS SIZED PER KW | | | OF UNIT AND NOT PER 65% DERATING.424-3 | | | SHOWN AS #6 ON PANEL SCHEDULE. | | | 4)NOTE: PLEASE NOTE PANEL "F" FEEDS "G" | | | AND LOAD EXCEEDS 80% RATING OF BRKR?/ | | | PLEASE ADJUST. | | | | | | 5)NOTE: PLEASE SEE LOAD FOR RANGE AND | | | CLARIFY LOAD AT 3KW? | | | | | | PLEASE GO OVER PLANS AND SUBMIT THE | | | ABOVE INFOMRATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | | | | 6)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED. 210-8-A-6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2002-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-25 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-25 |
Time |
10:29 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-06 |
Time |
21:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-06 |
Time |
21:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-18 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-18 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | *********** REVISION REQUESTED ********* | | | | | | PLEASE NOTE THAT NOT ALL ITEMS WERE | | | CHANGED ON THE PLANS BY ARCHITECT OF | | | RECORD. PLEASE NOTE MANY ITEMS WERE | | | REDLINED ON PLANS. THESE WERE COMMENTS | | | FROM FIRST TWO REVIEWS. | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | NOW THAT TWO MAIN DISCONNECTS ARE BEING | | | INSTALLED TO MEET GROUPING OF MAINS PER | | | 230-72. PLEASE SUBMIT AIC RATINGS FOR | | | MAINS. | | | | | | 2)NOTE: PLEASE NOTE THAT RISER DIAGRAM | | | NEEDS TO BE REVISED TO INCLUDE NEW MAIN | | | DISCONNECTS AND WIRING. | | | | | | 3)NOTE: PLEASE NOTE MISSING EQUIPMENT | | | GROUNING CONDUCTORS PER 250-122 BETWEEN | | | MAIN AND PANELS. | | | | | | 4)NOTE: PLEASE NOTE THAT PANELS NOW ONLY | | | NEED TO BE SHOWN AS "MLO". | | | | | | 5) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | | | | 6) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210-8-A-6. | | | | | | 7) NOTE: PLEASE SHOW GROUNDING ELECTRODE | | | GOING TO BUILDING STEEL. | | | PER 250-50. | | | | | | 8)NOTE: PLEASE NOTE MISSING OUTLETS AND | | | LTS REQ`D FOR AHU`S AND OUTLETS FOR | | | COND UNITS. 210-8/210-63/210-70/309.1 | | | | | | PLEASE SUBMIT THE ABOVE AS A REVISION | | | FOR REVIEW, BEFORE ANY ROUGH ELECTRICAL | | | INSPECTION IS CALLED IN. PLEASE ALSO | | | NOTE THAT THERE WILL BE A FEE DUE FOR | | | REVISION. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-29 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-29 |
Time |
19:55 |
Sent To |
|
|
| Notes |
| 2001-08-29 00:00:00 | ***************** UNSAT **************** | | | | | | PLEASE SEE THE FOLLOW NOTES, NOT ALL | | | NOTES WERE ADRESSED FROM FIRST REVIEW. | | | | | | 1)NOTE: PLEASE NOTE THAT ONE LINE DIA- | | | -GRAM SHOWS TWO PANELS, ONE LH AND ONE | | | RH. PLEASE CLARIFY LOCATIONS OF PANELS. | | | MAINS NEED TO BE GROUPED PER 230-72. | | | PLANS SHOW ONLY ONE PANEL IN GARAGE? | | | WHERE IS THE OTHER PANEL? | | | | | | 2)NOTE: PLEASE NOTE ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE ARE TO BE SHOWN AS | | | GFI/GFI PROTECTED PER 210-8-A-6. | | | PLEASE NOTE THAT OUTLET SPACING NEEDS TO | | | MEET 210-52-C-1. WITHIN 2' OF COUNTER | | | END AND EVRY 4' THER-AFTER. | | | | | | 3)NOTE: PLEASE NOTE MISSING REQ`D LIGHT | | | AND RECEPT FOR ALL AHU`S IN ATTIC SPACES | | | PER 210-70 AND 210-63. | | | PLEASE ALSO NOTE MISSING OUTLET FOR | | | COND UNITS PER 309-1 OF THE MECH CODE. | | | | | | 4)NOTE: PLEASE NOTE MISSING SOME OUTLETS | | | PER 210-52 UPSTAIRS. | | | | | | 5)NOTE: PLEASE NOTE THAT BLDG/FOOTER | | | STEEL IS REQ`D PER 250-50 FOR GROUNDING | | | ELECTRODE SYSTEM. | | | | | | PLEASE NOTE THAT SOME OF THE ITEMS ABOVE | | | COULD HAVE BEEN REDLINED ON PLANS BUT | | | MAIN SERVICE PANEL LOCATION ON PLANS | | | MUST BE GROUPED, GROUNDING ELECTRODE | | | TO BLDG. STEEL. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-12 |
Time |
21:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-12 |
Time |
21:21 |
Sent To |
|
|
| Notes |
| 2001-06-12 00:00:00 | ******************* UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT ALL PLANS THAT | | | ARE SIGNED AND SEALED ARE TO HAVE A | | | TITLE BLOCK 61G15-23.002 .ALSO PLANS | | | ARE TO BE DATED PER 481.221 AND 471.025 | | | WHEN SIGNED AND SEALED. | | | | | | 2) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 3) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | | | | 4) NOTE: PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52. | | | | | | | | | 5)NOTE: PLEASE NOTE THAT GARAGE OUTLETS | | | NEED TO BE SHOWN AS GFI/GFI PROTECTED | | | PER 210-8 | | | ALSO OUTSIDE OUTLETS. | | | | | | 6) PLEASE NOTE MISSING OUTLET(S) REQ`D | | | BY 210-52E OF THE NEC. | | | MISSING OUTLET IN FRONT | | | | | | 7)NOTE: PLEASE NOTE ALL A/C EQUIPMENT | | | NOT SHOWN ON PLANS. | | | MISSING DISCONNECTS PER 440-11 | | | PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. | | | | | | 8) NOTE: PLEASE SHOW ALL OUTLETS | | | SERVINGKITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECT--ED PER 210-8-A-6. | | | | | | 9)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 10)NOTE: PLEASE NOTE THAT PLANS DO NOT | | | SHOW LOCATIONS PF PANELS? PLEASE NOTE | | | GROUPING OF MAINS PER 230-72 | | | | | | 11)NOTE: PLEASE SHOW GROUNDING | | | ELECTRODEGOING TO BUILDING STEEL AND | | | COLD WATER | | | PER 250-50. | | | | | | 12)NOTE: PLEASE SUBMIT PANEL SCHEDULES | | | FOR BOTH PANELS. THIS MAY CHANGE IN THE | | | COARSE OF BLDG BUT IS REQ`D FOR | | | PRELIMINARY CIRCUITING. 215-5 | | | | | | 13)NOTE: PLEASE NOTE THAT LOAD | | | CALCULATIONS SHOW ALL AHU HEAT LOADS | | | BEING DERATED AT 40%. PLEASE CLARIFY. | | | ALL LOAD CALCSARE TO BE DONE IN ACCORD | | | TO NEC AND ART 220. PLEASE NOTE THAT | | | THE MAX DEDUCTION FOR DERATING AHU`S | | | AND HEAT STRIP LOADS IS 65%. PLEASE SEE | | | ART 220. | | | | | | 14)NOTE: PLEASE NOTE THAT SUB PANEL FOR | | | DOCK WAS NOT SHOWN ON RISER DIAGRAM?? | | | PLEASE SHOW ON LINE DIAGRAM. BEING SUB- | | | -PANEL FROM PANEL ?? SHOW ON PANEL | | | SCHEDULE. | | | CONDUIT SIZES/WIRE SIZES ETC. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
15:04 |
Sent To |
B |
|
| Notes |
| 2004-11-12 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-01 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-01 |
Time |
10:38 |
Sent To |
B |
|
| Notes |
| 2004-11-01 00:00:00 | TO JG DESK/SUBMITTAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-07 |
Time |
11:21 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-03-07 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | MECHANICAL PERMIT 02080612 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-06-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-06-06 |
Time |
19:02 |
Rev Time |
0.75 |
| Received By |
hmoser |
Date |
2001-06-06 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2001-06-06 00:00:00 | NO BATH EXHAUST ON MECHANICAL PLAN | | | BATH EXHAUST ON LIGHTING PLAN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-03-05 |
Time |
18:19 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-03-05 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2002-03-05 00:00:00 | PASSED/PROVISO: SUBMIT SANT RISER DIAG. | | | THAT REFLECTS FLOOR PLAN AND MEET SPC-94 | | | CODE REQUIREMENTS PRIOR TO FINAL INSP. | | | REVISION....... |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-25 |
Time |
10:29 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-07 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-08-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-08-25 |
Time |
07:28 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-08-25 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2001-08-25 00:00:00 | PROVISO; | | | REVISED RISER DIAGRAM REQUIRED BEFORE | | | PLUMBING FINAL. RISER DIAGRAM NOT TO | | | CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-06-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-02 |
Time |
10:59 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-06-02 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2001-06-02 00:00:00 | REVIEW NOTES:FAILED | | | | | | 1) PAGE A-10 SEC. 15400 PLUMBING NOTES. | | | PROVIDE MANUFACTURE SPECIFICATIONS FOR | | | LEAD WRAP PIPE SOUND INFORMATION. | | | | | | 2) SANITARY RISER DIAGRAM DOES NOT | | | COMPLY WITH SPC-94. SUBMIT RISER DIAGRAM | | | THAT MEETS CODE REQUIREMENTS AND | | | REFLECTS FLOOR LAYOUT AS IT WILL BE IN- | | | STALLED. | | | | | | REVIEW BY KEN STEVENS. ANY QUESTIONS | | | CALL (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
8 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2004-09-20 |
Time |
15:11 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2004-09-20 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
| 2004-09-20 00:00:00 | CHECKLIST: | | | 1-NEED PRODUCT APPROVAL FOR SINGLE ENTRY | | | DOOR WITH SIDELITES. PRODUCT APPROVAL | | | SUBMITTED DOESN'T INCLUDE THIS ASSEMBLY | | | | | | 2-PROVIDE INFORMATION AS REQUESTED ON | | | PROVISO DATED 2-25-02. SEE ATTACHED | | | COPY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 805-6712. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2002-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-05-24 |
Time |
14:27 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2002-05-24 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2002-05-24 00:00:00 | 1-TRUSS ENGINEER NEEDS TO FOLLOW FLORIDA | | | BOARD OF PROFESSIONAL ENGINEERS RULES | | | AND PROVIDE ORIGINAL SIGNATURE, DATE | | | AND USE EMBOSSED SEAL ON ALL THE | | | DOCUMENTS SUBMITTED FOR PUBLIC RECORDS | | | AS REQUIRED BY CHAPTER 471 FL STATUTES |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2002-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-05-20 |
Time |
15:06 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2002-05-20 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2002-05-20 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | 1-TRUSS ENGINEER TO SIGN, SEAL AND DATE | | | TRUSS PLAN AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTES. | | | 2-TRUSS ENGINEER TO PROVIDE ORIGINAL | | | SIGNATURE, SEAL AND DATE ON ALL | | | ENGINEERED DRAWINGS & MICROLLAM BEAMS | | | AS REQUIRED BY CHAPTER 471 FL STATUTES | | | 3-MICROLLAM BEAMS ENGINEERED BEAMS ARE | | | NOT LEGIBLE. ALSO, WHAT'S THE DESIGN | | | CRITERIA USED. ASCE 7-98 140MPH AS THE | | | ENGINEERED TRUSSES? | | | 4-ENGINEER OF RECORD TO REVISE TRUSS | | | ANCHOR SCHEDULE TO RESIST THE UPLIFT | | | LOADS AS CALCULATED ON THE ENGINEERED | | | TRUSSES. SEE ENGINEERED TRUSSES. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2002-02-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2002-02-25 |
Time |
17:08 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2002-02-25 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2002-02-25 00:00:00 | APPROVED WITH PROVISO: | | | 1-FLOOD ZONE A5. PROVIDE INSPECTOR WITH | | | ELEVATION CERTIFICATE. | | | 2-PROVIDE PRODUCT APPROVAL FOR: | | | A)ENTRY DOORS ASSEMBLY. | | | B)GARAGE DOORS. | | | | | | 3-REMOVE KITCHEN BY THE PLAY ROOM AREA | | | AS REQUESTED BY ZONING. | | | 4-MASONRY FENCES TO BE DONE UNDER A | | | SEPARATE PERMIT. | | | 5-STORM PANEL SHUTTERS FOR ENTRY DOOR. | | | A)CLEARLY INDICATE ON DRAWINGS ALL THE | | | COMPONENTS THAT ARE GOING TO BE USED | | | FOR THIS APPLICATION. SEE PAGE -2-. | | | B)PROVIDE COMPLETE INSTALLATION | | | SCHEDULE AND KEY PLAN. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2001-11-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-11-09 |
Time |
16:42 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-11-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2001-11-09 00:00:00 | PRODUCT APPROVAL REVIEW: | | | | | | 1-PRODUCT APPROVALS SUBMITTED ARE OK | | | EXCEPT FOR MAIN ENTRY DOOR ASSEMBLY. | | | NEED TO PROVIDE PRODUCT APPROVAL FOR | | | COMPLETE ASSEMBLY AS SHOWN ON THE | | | ARCHITECTURAL PLANS AND ELEVATIONS. | | | PRODUCT APPROVALS SUBMITTED FOR WOOD | | | FIXED WINDOW AND WOOD FRENCH DOORS ARE | | | FOR SINGLE UNITS ONLY AS SHOWN ON | | | APPROVED PLANS. SEE LIMITATIONS ON | | | SHEET #2 OF PRODUCT APPROVALS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-09-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-09-15 |
Time |
16:30 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2001-09-15 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2001-09-15 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-ENTRY DOORS WITH SIDELITES, FRENCH | | | DOORS WITH SIDELITES AND BAY WINDOWS | | | CALL FOR 2X STRUCTURAL MULLIONS. | | | PROVIDE COMPLETE SPECIFICATIONS AND | | | CONNECTION DETAILS SHOWING THE SUPPORT | | | TO STRUCTURE AND TO WINDOWS/DOORS. | | | -ALSO, CLARIFY WHAT ASSEMBLIES ARE | | | GOING TO USE THE STRUCTURAL MULLIONS | | | SUBMITTED IN THE PRODUCT APPROVAL. | | | 2-ENGINEER OF RECORD TO REVIEW ALL | | | WINDOW, DOORS, MULLIONS PRODUCT | | | APPROVALS TO ASSURE THAT THEY MEET THE | | | DESIGN PRESSURES HE CALCULATED. (USE | | | SHOP DRAWINGS REVIEW STAMP). | | | 3-PROVIDE PRODUCT APPROVAL FOR: | | | -ENTRY DOORS WITH SIDELITES ASSEMBLY. | | | -INSWING FRENCH DOORS. SEE PLANS. | | | -EXTERIOR SWING DOORS. SEE PLANS. | | | -UL LISTING FOR BBQ. | | | -PROVIDE UL LISTING FOR FIREPLACE AND | | | SUBMITT TWO COPIES. | | | 4-BORING TEST REPORT SHALL BE DONE | | | USING SECTION 1804.2.7 OF CITY | | | AMENDMENTS TO SBC 1997, NOT SOUTH | | | FLORIDA BUILDING CODE. | | | -PROVIDE TWO COPIES. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-09-10 |
Time |
19:46 |
Rev Time |
4.00 |
| Received By |
jgomez |
Date |
2001-09-11 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2001-09-10 00:00:00 | CHECKLIST: | | | 1-ENTRY DOOR SIZE DOESN'T PROVIDE THE | | | MINIMUM CLEAR OPENING (AT LEAST ONE | | | LEAF) OF 32" AS REQUIRED BY TABLE | | | 1004 SBC 1997. | | | 2-COMPLETE THE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM. | | | 3-PROVIDE SMOKE DETECTORS AT EACH STORY | | | AS REQUIRED BY SEC. 905.2 SBC 1997. | | | 4-ENTRY DOOR ASSEMBLY, FRENCH DOORS WITH | | | SIDELITES AND BAY WINDOWS CALL FOR | | | 2XSTRUCTURAL MULLIONS, BUT THERE IS | | | NOT SPECIFICATIONS FOR FASTENERS. | | | REMEMBER THAT THIS ASSEMBLIES WILL | | | HAVE MISSILE IMPACT GLAZING. | | | 5-ENGINEER OF RECORD TO REVIEW ALL | | | MISSILE IMPACT PRODUCT APPROVALS TO | | | VERIFY THAT THEY WILL MEET THE DESIGN | | | PRESSURES CALCULATED ON PLANS. | | | 6-PROVIDE PRODUCT APPROVALS FOR: | | | -INSWING FRENCH DOORS AS SHOWN ON PLANS | | | -EXTERIOR SWING DOORS. EG @ LAUNDRY,ETC | | | -UL LISTING FOR BBQ. | | | 7-OWES ADDITIONAL FEES OF $1234.68 FOR | | | LOW VALUATION AND RADON FEES. SEE | | | ATTACHED RECEIPT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-07-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-07-17 |
Time |
10:33 |
Rev Time |
6.00 |
| Received By |
jgomez |
Date |
2001-07-17 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2001-07-17 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | BRING STAMPED DRAWINGS AND RECEIPT. | | | 2-NEED TO FILE NOTICE OF COMMENCEMENT. | | | 3-PROVIDE SIGNED, SEALED AND DATED | | | SURVEY WITH NEW BUILDING LAYOUT AND | | | PROPOSED FINISH FLOOR ELEVATIONS. | | | 4-COMPLETE THE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM ATTACHED | | | 5-SPECIFY DESIGN PRESSURES CALCULATED AT | | | ALL EXTERIOR OPENINGS. SEC 1606 SBC/97 | | | 6-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR | | | OPENING (AT LEAST ON ONE LEAF) AS | | | REQUIRED BY TABLE 1004 SBC 1997. | | | 7-PROVIDE COMPLETE AREA TABULATIONS. EG: | | | A/C AREAS, PORCHES, GARAGE, BALCONIES. | | | 8-WINDOWS SPECIFIED DON'T PROVIDE THE | | | MIN CLEAR OPENINGS REQUIRED FOR EGRESS | | | SEC. 1005.4 SBC 1997. REVISE SIZE OF | | | WINDOWS AT GUEST BEDRM AND 2ND FLOOR | | | BEDRMS. ALSO, OFFICE AT 2ND FLOOR MAY | | | BE CONSIDERED AS A BEDRM, THEREFORE, | | | WINDOWS SHALL COMPLY W/ THIS SEC. TOO. | | | 9-PROVIDE ATTIC ACCESS AT GARAGE, LOGGIA | | | & MASTER BEDRM BALCONY. SEC 2309.6 SBC | | | 10-PROVIDE SMOKE DETECTORS AT EACH STORY | | | AS REQUIRED BY SEC. 905.2 SBC 1997. | | | 11-FLAT ROOF AND PARAPETS: | | | A)MIN SLOPE 1/4"/FT. SEC 1503.1.2.3 SBC | | | B)PROVIDE DRAINAGE FOR MASTER BEDROOM | | | BALCONIES AND EMERGENCY SCUPPERS AS | | | REQUIRED BY SEC. 1517.6.4 SBC 1997. | | | 12-SPECIFY ATTIC VENTILATION AS REQUIRED | | | BY SEC 2309.7 SBC 1997. | | | 13-ARCHITECT TO DATE DRAWINGS AT TIME OF | | | SEALING. CHAPTER 481 FLORIDA STATUTES | | | 14-REVISE DESIGN ASSUMPTION NOTES ON | | | SHEET S-1.1. ASCE 7-95 FOR 145MPH OR | | | SBC FOR 110 MPH. | | | 15-OWNER TO SIGN & DATE ENERGY CALCS. | | | 16-SOIL TEST REPORT TO HAVE ORIGINAL | | | SIGNATURE, DATE AND EMBOSSED SEAL AS | | | REQUIRED BY CHAPTER 471 FL. STATUTES. | | | 17-PROVIDE PRODUCT APPROVAL FOR: | | | A)ENTRY DOOR WITH SIDELITES AND TRANSOM | | | SINGLE ASSEMBLY AS SHOWN ON PLANS. | | | B)FIXED WINDOWS(NEED APPROVED DWGS) | | | C)FRENCH DOORS WITH SIDELITES SINGLE | | | ASSEMBLY AS SHOWN ON PLANS. | | | D)SWING DOORS. EG: @ LAUNDRY AND BATH. | | | E)UL LISTING AND SPECS FOR FIREPLACE. | | | F)UL LISTING AND SPECS FOR BBQ. | | | G)ROOF TILE. | | | H)FLAT ROOF SYSTEM. | | | I)WINDOW MULLIONS. | | | | | | 18-SEE PLANS FOR ADDITIONAL MINOR | | | COMMENTS AND PLEASE RETURN REVIEWED | | | SET IN ORDER TO EXPEDITE THE REVIEW | | | PROCESS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2002-03-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-25 |
Time |
11:33 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2002-02-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-25 |
Time |
16:01 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-25 00:00:00 | NO KITCHEN ALLOWED IN THE PLAYROOM | | | PROPERTY ZONED SF7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-01 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-06-01 |
Time |
13:06 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|