Plan Review Details - Permit 01051437
Plan Review Stops For Permit 01051437
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-06-27 Cont ID  
Sent By dpalmer Date 2001-06-27 Time 18:21 Rev Time 0.00
Received By dpalmer Date 2001-06-27 Time 18:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-06-12 Cont ID  
Sent By dpalmer Date 2001-06-12 Time 20:36 Rev Time 0.00
Received By dpalmer Date 2001-06-12 Time 20:36 Sent To  
Notes
2001-06-12 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 PLEASE NOTE THAT THE AIC RATING HAS BEEN
 SUBMITTED FOR THE PANELS BUT NOT FOR
 MAINS.
  
 2) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
  
 3) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 4) PLEASE NOTE MISSING OUTLET(S) REQ`D
 BY 210-52E OF THE NEC.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-07 Cont ID  
Sent By hmoser Date 2001-06-07 Time 17:51 Rev Time 0.33
Received By hmoser Date 2001-06-07 Time 17:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-18 Cont ID  
Sent By kstevens Date 2002-05-18 Time 16:54 Rev Time 0.00
Received By kstevens Date 2002-05-18 Time 16:53 Sent To  
Notes
2002-05-18 00:00:00REVISION OK - SANT RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By kstevens Date 2001-06-02 Time 13:09 Rev Time 0.25
Received By kstevens Date 2001-06-02 Time 13:09 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-06-27 Cont ID  
Sent By lhatten Date 2001-06-27 Time 20:10 Rev Time 4.00
Received By lhatten Date 2001-06-24 Time 20:08 Sent To  
Notes
2001-06-27 00:00:00REVIEW & STAMPED PLANS 06/24/2001
 CALC. FEES &PRINT CARDS 06/27/2001

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-01 Cont ID  
Sent By sgraham Date 2001-06-01 Time 14:16 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***