Plan Review Details - Permit 01051434
Plan Review Stops For Permit 01051434
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-06-27 Cont ID  
Sent By dpalmer Date 2001-06-27 Time 18:17 Rev Time 0.00
Received By dpalmer Date 2001-06-27 Time 18:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 22:14 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 22:14 Sent To  
Notes
2001-06-06 00:00:00****************** UNSAT **************
  
 1)NOTE:PLEASE SEE 210-52-C-3 FOR MISSING
 OUTLET AT PENINSULAR IN KITCHEN.
  
 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 AIC RATINGS HAVE BEEN SUBMITTED FOR
 PANELS BUT NOT FOR MAINS?
  
 3) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
 MISSING IN FAMILY ROOM.
  
 4) PLEASE NOTE MISSING OUTLET(S) REQ`D
 BY 210-52E OF THE NEC.
 FRONT RECEPT.
  
  
 5) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
 OUTSIDE AND IN ATTIC IN GARAGE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-26 Cont ID  
Sent By pkrauss Date 2001-10-26 Time 12:53 Rev Time 0.35
Received By pkrauss Date 2001-10-26 Time 12:53 Sent To  
Notes
2001-10-26 00:00:00AS-BUILTS

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By hmoser Date 2001-06-02 Time 13:40 Rev Time 0.33
Received By hmoser Date 2001-06-02 Time 13:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By kstevens Date 2001-06-02 Time 07:00 Rev Time 0.33
Received By kstevens Date 2001-06-02 Time 07:00 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-06-27 Cont ID  
Sent By lhatten Date 2001-06-27 Time 20:27 Rev Time 4.00
Received By lhatten Date 2001-06-24 Time 20:26 Sent To  
Notes
2001-06-27 00:00:00REVIEW & STAMPED PLANS 06/24/2001
 CALC. FEES & PRINT CARDS 06/27/2001

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-01 Cont ID  
Sent By sgraham Date 2001-06-01 Time 13:25 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***