Plan Review Details - Permit 01051400
Plan Review Stops For Permit 01051400
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-12-10 Cont ID  
Sent By dpalmer Date 2001-12-10 Time 15:51 Rev Time 0.00
Received By dpalmer Date 2001-12-10 Time 15:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-12-05 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 19:19 Rev Time 0.00
Received By dpalmer Date 2001-12-05 Time 19:19 Sent To P
Notes
2001-12-05 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASENOTE THAT LOCATION OF
 POOL PANEL IS NOT SHOWN ON PLANS.
 GROUPING OF MAINS? 230-72 PLEASE NOTE
 THAT POOL PANEL IS SHOWN ONRISER
 DIAGRAM COMING FROM METERCAN? PLEASE
 CLARIFY METER/MAIN COMBO AND WHY ISNT
 POOL PANEL BEING FED FROM THIS METER/MAI
 N LIKE A/C UNIT? PLEASE CLARIFY
  
 2)NOTE: PLEASE NOTE THAT PLANS AND
 PANEL SCHEDULES SHOWN METER/MAIN AND
 RSIER DIAGRAM IS NOT CLEAR ON THIS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-07-28 Cont ID  
Sent By rmcdouga Date 2001-07-28 Time 11:29 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-28 00:00:00REVISION TO ADD 4 HI-HATS IN LIBRARY
 O.K. PER B.GERWE. 7-28-01 RM

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 23:04 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 23:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By hmoser Date 2001-06-02 Time 14:57 Rev Time 0.33
Received By hmoser Date 2001-06-02 Time 14:56 Sent To  
Notes
2001-06-02 00:00:00PROVISO INSTALL EX.FAN IN BEDROO #3
 BATHROOM

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-12-08 Cont ID  
Sent By kstevens Date 2001-12-08 Time 09:01 Rev Time 0.50
Received By kstevens Date 2001-12-08 Time 09:01 Sent To  
Notes
2001-12-08 00:00:00REVISED SANITARY RISER DIAGRAM/REVERSED

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-16 Cont ID  
Sent By dpalmer Date 2001-12-05 Time 19:21 Rev Time 0.33
Received By jleech Date 2001-07-16 Time 18:02 Sent To  
Notes
2001-07-16 00:00:00PROVISO; PIPE AS SIZED IN RED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-02 Cont ID  
Sent By kstevens Date 2001-06-02 Time 07:55 Rev Time 0.25
Received By kstevens Date 2001-06-02 Time 07:55 Sent To  
Notes
2001-06-02 00:00:00REVIEW NOTES: FAILED
  
 SUBMIT SANITARY RISER DIAGRAM THAT
 MATCHES FLOOR PLAN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-07-27 Cont ID  
Sent By rmcdouga Date 2001-07-27 Time 15:46 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-27 00:00:00REVISION TO REPLACE FRENCH DOORS AT
 FAMILY ROOM WITH SLIDING GLASS DOORS IS
 OK 7-27-01.RM

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-07-19 Cont ID  
Sent By rmcdouga Date 2001-07-19 Time 11:21 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-19 00:00:00TRUSSES
 USAT
  
 1) TRUSS DRAWINGS AND LAYOUT MUST BE
 REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD FOR THE STRUCTURE. IF THE TRUSSES
 ARE ACCEPTABLE THE DESIGN PROFESSIONAL
 IS TO SIGN AND SEAL THE TRUSS LAYOUT.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-07-19 Cont ID  
Sent By rmcdouga Date 2001-07-19 Time 10:44 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-02 Cont ID  
Sent By rmcdouga Date 2001-07-02 Time 16:28 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-02 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) PROVIDE (2) COPIES OF MANUAL J
 CALCUALTIONS AS REQUIRED BY THE FLORIDA
 ENERGY EFFICIENCY CODE.
  
 3) DETAIL A3 IS MISLABELED AS A4 ON
 SHEET 3A. PLEASE CORRECT.
  
 4) INDICATE REQUIRED TIE BEAMS FROM THE
 SCHEDULE FOR THE FRENCH DOORS AND
 SLIDING GLASS DOORS THAT OPEN ONTO THE
 LANAI. (SEE SHEET 3A)
  
 5) INDICATE THE CONNECTIONS FOR GIRDER
 FG1 TO THE COLUMNS AT THE LANAI.
  
 6) INDICATE THE CONNECTORS FOR GIRDER
 HG7 AND TRUSS T8 ON SHEET 3A.
  
 7) PROVIDE REVISED STORM PANEL KEY PLAN
 AND INSTALLATION SCHEDULE THAT
 CORRESPOND TO THE OPTIONS THAT ARE GOING
 TO BE USED.
  
 NOTE: STRUCTURE IS LOCATED IN AN "A"
 FLOOD ZONE AN ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 TRUSSES
 UNSAT
  
 1) THE MEAN ROOF HEIGHTS GIVEN ON THE
 TRUSS DRAWINGS DIFFER FROM EACH OTHER
 AND DO NOT CORRESPOND WITH THE MEAN ROOF
 HEIGHT OF THE STRUCTURE (17FT.). PLEASE
 CORRECT.
  
 2) THE DESIGN CRITERIA LISTED ON THE
 TRUSS DRAWINGS SHOULD BE 1997 STANDARD
 BUILDING CODE (SBC) AND NOT THE SBCCI,
 WHICH IS AN ORGANIZATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-01 Cont ID  
Sent By sgraham Date 2001-06-01 Time 13:19 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***