Plan Review Details - Permit 01051399
| Plan Review Stops For Permit 01051399 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-12 |
Time |
20:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-12 |
Time |
20:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-11-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-26 |
Time |
14:43 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-11-26 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2001-11-26 00:00:00 | MECH REV PERMIT 01051418 - EXHAUST FAN | | | REVISION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-06-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-06-07 |
Time |
18:21 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-06-07 |
Time |
18:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-02 |
Time |
13:36 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2001-06-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2001-06-02 00:00:00 | REVIEW NOTES: FAILED | | | | | | SUBMIT SANITARY RISER DIAGRAM THAT | | | REFLECTS FLOOR PLAN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-09-06 |
Time |
15:46 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-07-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-07-02 |
Time |
11:20 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-02 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) ON SHEET 3A, DETAIL A3 IS MISLABELED | | | AS A4. PLEASE CORRECT. | | | | | | 3) PROVIDE CONNECTION DETAILS FOR GIRDER | | | FG1 AT THE COLUMNS ON SHEET 3A. | | | | | | 4) INDICATE THE CONNECTORS FOR GIRDERS | | | HGT AND T8. | | | | | | 5) ON SHEET 4A THE RIGHT ELEVATION IS | | | MISTAKENLY LABELED AS LEFT ELEVATION. | | | PLEASE CORRECT. | | | | | | 6) PROVIDE MANUAL J CALCULATIONS AS | | | REQUIRED BY 1997 FLORIDA ENERGY | | | EFFICIENCY CODE. | | | | | | 7) THE TIE BEAM ELEVATION OF 15'-0" AT | | | THE BOTTOM OF SHEET 4A IS INCORRECT. IT | | | SHOULD BE 12'-0". PLEASE CORRECT. | | | | | | | | | TRUSSES | | | UNSAT | | | | | | 1) THE MEAN ROOF HEIGHTS GIVEN ON THE | | | TRUSS DRAWINGS ARE INCONSISTENT WITH | | | EACH OTHER AND DO NOT CONCUR WITH THE | | | MEAN ROOF HEIGHT OF THE STRUCTURE. | | | PLEASE CORRECT. | | | | | | 2) THE TRUSS DRAWINGS INCORRECTLY | | | REFERENCE THE 97 SBCCI,WHICH IS AN | | | ORGANIZATION. THE PROPER REFERENCE WOULD | | | BE THE 97 SBC, WHICH IS THE ACTUAL CODE. | | | PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-01 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-06-01 |
Time |
14:15 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|