Plan Review Details - Permit 01051240
Plan Review Stops For Permit 01051240
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 21:55 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 21:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By hmoser Date 2001-06-02 Time 13:15 Rev Time 0.33
Received By hmoser Date 2001-06-02 Time 13:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-10-17 Cont ID  
Sent By kstevens Date 2001-10-10 Time 15:15 Rev Time 0.33
Received By kstevens Date 2001-10-10 Time 15:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-16 Cont ID  
Sent By jleech Date 2001-07-16 Time 18:47 Rev Time 0.33
Received By jleech Date 2001-07-16 Time 18:46 Sent To  
Notes
2001-07-16 00:00:00PROVISO; REVISED RISER DIAGRAM REQUIRED
 BEFORE FINAL INSPECTION. RISER DIAGRAM
 TO REFLECT FLOOR PLAN.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-31 Cont ID  
Sent By kstevens Date 2001-05-31 Time 18:41 Rev Time 0.25
Received By kstevens Date 2001-05-31 Time 18:41 Sent To  
Notes
2001-05-31 00:00:00REVIEW NOTES:FAILED
  
 SANITARY RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN.
 WASH MACHINE CAN NOT ENTER STACK ON A
 CROSS WITH LAUNDRY SINK.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-08-09 Cont ID  
Sent By rmcdouga Date 2001-08-09 Time 13:35 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-09 00:00:00TRUSSES OK

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-07-18 Cont ID  
Sent By rmcdouga Date 2001-07-18 Time 15:59 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-18 00:00:00TRUSSES
 UNSAT
  
 1) TRUSS DRAWINGS AND LAYOUT MUST BE
 REVIEWED AND APPROVED BY THE DESIGNER
 OF RECORD FOR THE STRUCTURE. THE TRUSS
 LAYOUT SHOULD BE SIGNED AND SEALED BY
 THE DESIGN PROFESSIONAL IF THE TRUSSES
 ARE ACCEPTABLE FOR USE ON THE STRUCTURE.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-07-18 Cont ID  
Sent By rmcdouga Date 2001-07-18 Time 14:30 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-06-28 Cont ID  
Sent By rmcdouga Date 2001-06-28 Time 13:17 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-06-28 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATED IN AN"A" FLOOD
 ZONE. A FLOOD ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 3) THE ROOF FRAMING PLAN LOCATED ON
 SHEET 3 IS A REVERSE OF THE OTHER
 DRAWINGS SUBMITTED. PLEASE CORRECT.
  
 4) DETAIL A ON SHEET 3 IS NOT SHOWN.
  
 5) PROVIDE DETAIL OF CANTILEVERED BEAM
 REINFORCEMENT AT LANAI.
  
 6) PROVIDE (2) COPIES OF INSTALLATION
 SCHEDULE AND KEY PLAN FOR STORM PANELS.
  
 TRUSSES
 UNSAT
  
 1) THE MEAN ROOF HEIGHT GIVEN ON TRUSS
 DRAWINGS IS NOT CONSISTENT. H7A HAS
 11.73 FT.,HJ1 HAS 15FT,HJ5 HAS 15.8FT.,
 ETC. PLEASE CORRECT.
  
 2) DRAWINGS LIST SBCCI 97, SOUTHERN
 BUILDING CODE CONGRESS INTERNATIONAL IS
 THE NAME OF THE ORGINAZATION NOT THE
 ACTUAL MODEL CODE, WHICH IS THE 1997
 STANDARD BUILDING CODE OR 97 SBC. PLEASE
 CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-28 Cont ID  
Sent By rmcdouga Date 2001-06-28 Time 13:14 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-06-28 00:00:00OK PER S.GRAHAM 5-29-01 RM