| Plan Review Stops For Permit 01051240 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-06-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-06 |
Time |
21:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-06 |
Time |
21:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-06-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-06-02 |
Time |
13:15 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-06-02 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-10-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-10 |
Time |
15:15 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-10 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-16 |
Time |
18:47 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-07-16 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2001-07-16 00:00:00 | PROVISO; REVISED RISER DIAGRAM REQUIRED | | | BEFORE FINAL INSPECTION. RISER DIAGRAM | | | TO REFLECT FLOOR PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-05-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-05-31 |
Time |
18:41 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2001-05-31 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2001-05-31 00:00:00 | REVIEW NOTES:FAILED | | | | | | SANITARY RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN. | | | WASH MACHINE CAN NOT ENTER STACK ON A | | | CROSS WITH LAUNDRY SINK. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2001-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-08-09 |
Time |
13:35 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-09 00:00:00 | TRUSSES OK |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2001-07-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-07-18 |
Time |
15:59 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-18 00:00:00 | TRUSSES | | | UNSAT | | | | | | 1) TRUSS DRAWINGS AND LAYOUT MUST BE | | | REVIEWED AND APPROVED BY THE DESIGNER | | | OF RECORD FOR THE STRUCTURE. THE TRUSS | | | LAYOUT SHOULD BE SIGNED AND SEALED BY | | | THE DESIGN PROFESSIONAL IF THE TRUSSES | | | ARE ACCEPTABLE FOR USE ON THE STRUCTURE. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-07-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-07-18 |
Time |
14:30 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-06-28 |
Time |
13:17 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-28 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) STRUCTURE IS LOCATED IN AN"A" FLOOD | | | ZONE. A FLOOD ELEVATION CERTIFICATE WILL | | | BE REQUIRED. | | | | | | 3) THE ROOF FRAMING PLAN LOCATED ON | | | SHEET 3 IS A REVERSE OF THE OTHER | | | DRAWINGS SUBMITTED. PLEASE CORRECT. | | | | | | 4) DETAIL A ON SHEET 3 IS NOT SHOWN. | | | | | | 5) PROVIDE DETAIL OF CANTILEVERED BEAM | | | REINFORCEMENT AT LANAI. | | | | | | 6) PROVIDE (2) COPIES OF INSTALLATION | | | SCHEDULE AND KEY PLAN FOR STORM PANELS. | | | | | | TRUSSES | | | UNSAT | | | | | | 1) THE MEAN ROOF HEIGHT GIVEN ON TRUSS | | | DRAWINGS IS NOT CONSISTENT. H7A HAS | | | 11.73 FT.,HJ1 HAS 15FT,HJ5 HAS 15.8FT., | | | ETC. PLEASE CORRECT. | | | | | | 2) DRAWINGS LIST SBCCI 97, SOUTHERN | | | BUILDING CODE CONGRESS INTERNATIONAL IS | | | THE NAME OF THE ORGINAZATION NOT THE | | | ACTUAL MODEL CODE, WHICH IS THE 1997 | | | STANDARD BUILDING CODE OR 97 SBC. PLEASE | | | CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2001-06-28 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-28 00:00:00 | OK PER S.GRAHAM 5-29-01 RM |
|
|