Plan Review Details - Permit 01051239
Plan Review Stops For Permit 01051239
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 21:36 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 21:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By hmoser Date 2001-06-02 Time 10:40 Rev Time 0.33
Received By hmoser Date 2001-06-02 Time 10:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-10-30 Cont ID  
Sent By kstevens Date 2001-10-30 Time 20:12 Rev Time 0.50
Received By kstevens Date 2001-10-30 Time 20:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-10-10 Cont ID  
Sent By kstevens Date 2001-10-10 Time 15:10 Rev Time 0.33
Received By kstevens Date 2001-10-10 Time 15:10 Sent To  
Notes
2001-10-10 00:00:00DENIED
  
 REVISION DOES NOT REFLECT FLOOR PLAN.
 PLEASE SUBMIT A SANITARY RISER DIAGRAM
 THAT REFLECTS THE INSTALLATION OF THE
 SYSTEM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-16 Cont ID  
Sent By jleech Date 2001-07-16 Time 17:23 Rev Time 0.33
Received By jleech Date 2001-07-16 Time 17:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-30 Cont ID  
Sent By kstevens Date 2001-05-30 Time 18:48 Rev Time 0.25
Received By kstevens Date 2001-05-30 Time 18:48 Sent To  
Notes
2001-05-30 00:00:00REVIEW NOTES:FAILED
  
 SANITARY RISER DIAGRAM DOES NOT REFLECT
 FLOOR PLAN.
 PLEASE SUBMIT A RISER DIAGRAM THAT
 MATCHES THE FLOOR PLAN FOR PLAN REVIEW.
 SPC-94 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT.8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-07-17 Cont ID  
Sent By lsmith Date 2001-07-17 Time 07:53 Rev Time 1.50
Received By lsmith Date   Time   Sent To  
Notes
2001-07-17 00:00:00************BUILDING PROVISO************
  
 PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH BFE
 SBC 104.2.2

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-03 Cont ID  
Sent By lsmith Date 2001-07-03 Time 13:00 Rev Time 3.50
Received By lsmith Date   Time   Sent To  
Notes
2001-07-03 00:00:00*************BUILDING UNSAT*************
  
 LEA SMITH, BLDG. PLANS EXAMINER
 659-8096 EXT 8394
  
  
 1. PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BFEBEFORE C/O.
  
 2. PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 SINGLE FRENCH DOORS (SUBMITTED
 APPROVALS EXPIRED 4/2/01)
  
 3. DETAIL A/3 ON SHEET 3B: REBENDING OF
 FLANGE ON GIRDER HANGER IS NOT ALLOWED
 PER MFGR.CAPACITY OF HANGER NEEDS TO
 BE DERATED.PLEASE CORRECT.
  
 4. DESIGN PARAMETERS ON SHEET 1 LISTS
 26 PSF & MEAN ROOF HEIGHT AS 17'.
 PLEASECORRECT AS PER PLAN.
  
 5. INDICATE ON GLASS BLOCK SUBMITTALS
 WHICH TYPE BEING USED.
  
 PLEASE RESUBMIT WHEN ABOVE CORRECTIONS
 ARE COMPLETED.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-29 Cont ID  
Sent By sgraham Date 2001-05-29 Time 10:05 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***