Plan Review Details - Permit 01051238
Plan Review Stops For Permit 01051238
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 21:12 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 21:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-02 Cont ID  
Sent By hmoser Date 2001-06-02 Time 10:13 Rev Time 0.33
Received By hmoser Date 2001-06-02 Time 10:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-06 Cont ID  
Sent By kstevens Date 2001-11-06 Time 14:55 Rev Time 0.50
Received By kstevens Date 2001-11-06 Time 14:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-05-29 Cont ID  
Sent By kstevens Date 2001-05-29 Time 15:31 Rev Time 0.25
Received By kstevens Date 2001-05-29 Time 15:31 Sent To  
Notes
2001-05-29 00:00:00REVIEW NOTES:PASSED
  
 PROVISO:
  
 SUBMIT SANITARY RISER THAT REFLECTS THE
 FLOOR PLAN BEFORE ROUGH INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-08-09 Cont ID  
Sent By rmcdouga Date 2001-08-09 Time 13:38 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-09 00:00:00TRUSSES OK

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-07-18 Cont ID  
Sent By rmcdouga Date 2001-07-18 Time 10:36 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-18 00:00:00TRUSSES
 UNSAT
  
 1) TRUSS DRAWINGS AND LAYOUT MUST BE
 REVIEWED AND APPROVED BY THE DESIGNER OF
 RECORD OF THE STRUCTURE. THE DESIGN
 PROFESSIONAL IS REQUIRED TO SIGN & SEAL
 THE TRUSS LAYOUT IF THEY ARE ACCEPTABLE.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-07-18 Cont ID  
Sent By rmcdouga Date 2001-07-18 Time 09:43 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-06-29 Cont ID  
Sent By rmcdouga Date 2001-06-29 Time 15:42 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-06-29 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) STRUCTURE IS LOCATED IN AN "A" FLOOD
 ZONE. AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 3) THE ROOF FRAMING PLAN LOCATED ON
 SHEET 3 IS A REVERSE OF THE OTHER
 DRAWINGS SUBMITTED. PLEASE CORRECT.
  
 4) DETAIL A ON SHEET 3 IS NOT SHOWN.
  
 5) PROVIDE DETAIL OF CANTILEVERED BEAM
 REINFORCEMENT AT LANAI.
  
 6) PROVIDE (2) COPIES OF INSTALLATION
 SCHEDULE AND KEY PLAN FOR STORM PANELS.
  
 7) OWNER/AGENT SIGNATURE IS REQUIRED ON
 ENERGY CALCULATIONS.
  
 TRUSSES
 UNSAT
  
 1) THE MEAN ROOF HEIGHT GIVEN ON TRUSS
 DRAWINGS IS NOT CONSISTENT. MEAN ROOF
 HEIGHT OF STRUCTURE IS 15 FT. PLEASE
 CORRECT.
  
 2) DRAWINGS REFERENCE 97 SBCCI, WHICH IS
 THE ORGANIZATION. THE 97 SBC (STANDARD
 BUILDING CODE) IS THE MODEL CODE THAT
 SHOULD BE REFERENCED. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-29 Cont ID  
Sent By sgraham Date 2001-05-29 Time 10:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***