Plan Review Details - Permit 01051214
| Plan Review Stops For Permit 01051214 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-07-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-07-13 |
Time |
06:54 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-06-05 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-06-05 |
Time |
13:35 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-05 00:00:00 | ***********FAILED 6/5/01 LEA | | | SMITH******1. APPLICATION SHOWS | | | PREMANUFACTURED SPA2. DRAWINGS SHOW | | | EQUIPMENT NOT CONTAINEDIN SPA UNIT, | | | LOCATED ONSIDE OF HOUSE. PLEASE | | | CLARIFY WHAT EQUIPTMENT WILL BE | | | LOCATED AT THE SIDE OF THE HOUSE. | | | 3. DRAWING SHOWS EXTENSIVE TILE/PAVER | | | WORK WITH NO DETAIL FOR CONSTRUCTION. | | | NEED WALL SECTION SHOWING METHOD OF | | | AND TYPE OF WALL TO BE CONSTRUCTED | | | AROUND THE SPA. | | | 4. NEED TO LIST ON THE PLANS THE SYSTEM | | | OF COMPLIANCE WITH THE STATE POOL SAFETY | | | ACT SEC 515 FOR PROTECTION OF THE AREA | | | BETWEEN THE HOUSE AND SPA. | | | 5. SEE OTHER COMMENTS FROM PLUMBING & | | | ELEC FOR THEIR REQUIREMENTS. | | | 6. NEED COPY OF CONTRACT TO VERIFY VALUE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-12 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-12 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-05 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-05 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2001-07-05 00:00:00 | **************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT AN ELECTRICAL | | | PERMIT IS REQUESTED AND NO ELECTRICAL | | | PLANS/DRAWINGS WERE SUBMITTED? | | | | | | PLEASE SUBMIT FOR REVIEW | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-05-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2001-05-31 |
Time |
09:18 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2001-05-31 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2001-05-31 00:00:00 | NO ELECTRIC SHOWN |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-07-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-07-12 |
Time |
14:08 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-07-11 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-06-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-28 |
Time |
13:15 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-06-28 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2001-06-28 00:00:00 | FAILED | | | | | | 1) NOT ENOUGH INFORMATION. PLEASE SHOW | | | COMPLETE PIPING DIAGRAM WITH DETAILS AT | | | POOL EQUIPMENT. SHOW PUMP, FILTER, HEAT- | | | ER, ECT. WITH VALVES ECT. | | | (EXAMPLE INCLUDED WITH NOTES.) | | | | | | 2) GIVE DETAILS OF PIPING AT SPA. SHOW | | | HOW ALL 7 LINE TIE INTO SPA. | | | | | | 3) COMMENT #1 FROM PREVIOUS PLAN REVIEW | | | NOT ADDRESSED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-01 |
Time |
08:12 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-06-01 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2001-06-01 00:00:00 | REVIEW NOTES:FAILED | | | | | | 1) SUBMIT ALL INFORMATION FROM | | | MANUFACTURE ON SPA INCLUDING PUMPS | | | AIR BLOWER ECT. | | | | | | 2) BACKFLOW WILL BE REQUIRED ON WATER | | | SERVICE. | | | | | | 3) SUPPLY PIPING DIAGRAM FROM EQUIPMENT | | | TO SPA. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-05-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-05-25 |
Time |
13:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy