| Plan Review Stops For Permit 01050966 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-10-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-15 |
Time |
10:39 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-15 00:00:00 | REVISION #4 09/20/01 OKJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-07-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-23 |
Time |
14:46 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-06-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-06-07 |
Time |
16:29 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-07 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01050966 | | | 1 N. CLEMATIS SUITE 5TH FLOOR | | | | | | 1)- A SUITE # WILL BE REQUIRED TO | | | COMPLETE THE ADDRESS. | | | | | | 2)- FL ACCESSIBILITY CODE: OFFICE #4 | | | SHEET A2-E REQUIRES 18" CLEARENCE PER | | | FL ACC CODE 4.13.6. | | | | | | 3)- SHEET A6-E DETAIL #7 PER U-465 UL | | | LISTING, STUD SPACING NOT GIVEN. | | | | | | 4)- SHEET A6-E DEAIL #7 CORRIDOR PARTI- | | | TIONS & FIRE RATED WALLS REQUIRED TO | | | HAVE PROTECTED OPENINGS SHALL PERMANETLY | | | IDENTIFY WITH SIGNS OR STECLING "FIRE & | | | SMOKE BARRIER PROTECT ALL OPENINGS". | | | | | | 5)- SBC 704.2.1.2. DETAILS 6& 7 OF A6-E | | | ALL PARTITIONS REQUIRED TO HAVE FIRE RES | | | ISTANCE RATING SHALL EXTEND FROM THE TOP | | | OF THE FLOOR BELOW TO THE CEILING ABOVE | | | AND SHALL BE SECURELY ATTACHED & SEALED, | | | HAVING A FIRE RESISTANCE RATING AT LEAST | | | EQUAL FOR THE PARTITION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-10 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-10 |
Time |
18:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-10 |
Time |
20:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-10 |
Time |
20:05 |
Sent To |
|
|
| Notes |
| 2001-09-10 00:00:00 | ***************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT PER FS/FAC | | | PLANS MUST CONTAIN ORIG WET SIGNATURE | | | OF ARCHITECT.PLEASE NOTE THAT PLANS ARE | | | HAVE A STAMPED SIG. NOT PERMITTED PER | | | 61G15-23.002, 481.221. | | | | | | 2)NOTE: PLEASE ALSO NOTE THAT PLANS ARE | | | NOTE SIGNED, DATED AND SEALED BY THE | | | ORIGINAL ENGINEERS OF RECORD. "KAMM" | | | FOR ALL "M,E,P" DRAWINGS BOTH SETS. | | | | | | 3)NOTE: PLEASE NOTE THAT E5.1 DOES NOT | | | INDICATE ANY CHANGES? CLOUDS? ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-06-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-07 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-07 |
Time |
18:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-06-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-06-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-10-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-10-16 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-10-16 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-09-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-11 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-11 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2001-09-11 00:00:00 | PLANS DO NOT HAVE ORIGINAL SIGNATURE. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-22 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-22 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | 1) INTERIOR FINISH TO BE A MINIMUM OF | | | CLASS C ON THE WALLS AND CEILINGS. | | | 2) AN ADDITIONAL EMERGENCY LIGHT MAY | | | BE NEEDED NEAR THE WAITING ROOM. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-10-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-10-13 |
Time |
07:16 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-10-13 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2001-10-13 00:00:00 | *******************DENIED*************** | | | | | | | | | ENGINEER TO REVISE DWGS AS PER CONVERSAT | | | ION 10-17-01 WITH D. FRICK (KAMM) PHK | | | | | | | | | | | | | | | PLANS INDICATE REMOVING FIRE DAMPER TO | | | NEW LOCATION.LOCATION NOT SPECIFIED. | | | | | | ALL PENETRATIONS THROUGH A FIRE RATED | | | WALL SHALL HAVE PROTECTION BY MEANS OF | | | A FIRE DAMPER AS PER 1997 SMC 610.1.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2001-09-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-24 |
Time |
12:19 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-09-24 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2001-09-24 00:00:00 | ******************DENIED**************** | | | | | | | | | PLANS ARE NOT SEALED, SIGNED OR DATED | | | BYTHE ENGINEER OF RECORD (KAMM). | | | | | | PLEASE ALSO NOTE SIGNATURE FOR THE | | | ARCHITECT IS A STAMP AND NOT AN | | | ORIGINAL SIGNATURE.PLANS ARE | | | OTHERWISE ACCEPTABLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-07-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-07-23 |
Time |
10:36 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-07-23 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2001-07-23 00:00:00 | PROVISO FROM 6-8-01, ENGINEER RESPONSE | | | -FIRE DAMPER INSTALLED PREVIOUSLY AND | | | INSPECTED - APPROVED INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-06-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-08 |
Time |
08:17 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-06-08 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2001-06-08 00:00:00 | *******************PROVISO************** | | | | | | DRAWING M2.1 INDICATES THE FIRE DAMPER | | | IN THE EQUIPMENT ROOM (523) PENETRATING | | | THE WALL ON A DIAGONAL, PLEASE | | | REFERENCE MANUFACTURER INSTALLATION | | | INSTRUCTIONS. | | | | | | RATED WALL MAY HAVE TO BE BUILT OUT AS | | | TO ACCOMIDATE FIRE DAMPER TO PENETRATE | | | WALL PERPENDICULAR. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-11 |
Time |
14:22 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-10-11 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2001-10-11 00:00:00 | DENIED | | | REFERENCE: SPC-94- FLA STATE STATUES | | | | | | 1) WATER HAMMER NOT INSTALLED IN PROPER | | | LOCATION. PLEASE INSTALL CLOSE TO FIX- | | | TURE PER MANUFACTURE INSTALLATION INSTRU | | | CTIONS AND WH-PDI 201. | | | | | | 2) SHEET PO.1 NOT SEALED AS REQUIRED PER | | | 61G15-23.002(1). PLEASE SEAL PLANS AS | | | REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-09-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-09-06 |
Time |
17:13 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-09-06 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2001-09-11 00:00:00 | DENIED | | | | | | PLANS DO NOT HAVE ORIGINAL SIGNATURE BY | | | ARCHITECT, (STAMPED). ALSO PLANS ARE NOT | | | SIGNED AND SEALED BY ENGINEER OF RECORD. | | | | | | ALSO PAGE PO.1 WATER RISER DIAGRAM, | | | (MARKED FLOOR DRAIN DETAIL), WATER HAM- | | | MER ARRESTOR NOT INSTALLED CORRECTLY. | | | PLEASE SHOW INSTALLATION PER MANUFACTURE | | | INSTALLATION INSTRUCTION AND PER WH-PDI | | | 201. | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-07-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-22 |
Time |
11:26 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2001-07-22 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-05-31 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-05-31 |
Time |
14:18 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-31 00:00:00 | PLUMBING PLAN RVIEWDENIED | | | (1) SHT A2-E,RM 591, BATH RM TO COMPLY | | | W/ FACBC 97 SEC 4.1.3(11) COMMON USE | | | BATH RM'S AT LEAST ONE LAV & ONE SHOWER | | | TO COMLPY WITH CLEAR FLR SPACE AND | | | GRAB BARS. | | | (2) SHT A2-E RM 590, BREAK RM SINK | | | COMPLY W FACBC 97 SEC 4.24.3 KNEE CLEAR- | | | ANCE, SEC 4.24.5 CLEAR FLR SPACE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-06-08 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-06-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|