|
 |
 |
 |
 |
 |
Plan Review Details - Permit 01050922
| Plan Review Stops For Permit 01050922 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-07-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-02 |
Time |
17:09 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-13 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-13 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-06-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-11 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-11 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2001-06-11 00:00:00 | ****************** UNSAT ************** | | | | | | 1) NOTE: PLEASE SHOW ALL CONTINUOUS AT | | | 125%. (LIGHTING ETC) | | | PLEASE CLARIFY THE LOADS SHOWN. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | PLEASE NOTE THAT THE AIC RATING WAS | | | SUBMITTED FOR PANEL, BUT NOT FOR MAIN. | | | | | | 3) PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. | | | | | | 4) PLEASE CLARIFY EQUIPMENT GROUNDING | | | METHOD BETWEEN FIRST MEANS OF DISCONNECT | | | AND PANEL(S). EQUIPMENT GROUNDING | | | CONDUCTORS ARE TO BE SIZED BY 250-122. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-22 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-22 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | 1) INTERIOR FINISH SHALL BE CLASS A OR | | | B IN EXITS. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096 EXT. 8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-14 |
Time |
13:35 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-08-14 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-06-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-14 |
Time |
08:35 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-06-14 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2001-06-14 00:00:00 | ********************DENIED************** | | | | | | | | | PLEASE PROVIDE OUTSIDE AIR CALCULATIONS | | | AS PER ASHRAE 62-89. | | | | | | PLEASE PROVIDE AIR BALANCE SCHEDULE FOR | | | COMPLIANCE WITH 1997 SMC 501.2. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-08-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-08-09 |
Time |
10:14 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-09 00:00:00 | PLUMBING PLAN REVIEW,PROVISO. | | | SHT A3-2 MIN HGTH ON D/F 27"AFF. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-06-12 |
Time |
08:48 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-27 00:00:00 | PLUMBING PLAN REVIEW "DENIED" | | | SPC 94 TAB 407, 1 D/F REQ | | | END OF COMMENTS PAUL SCHMITZ | | | QUESTIONS 561-659-8096 X 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-08-14 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |