Plan Review Details - Permit 01050919
| Plan Review Stops For Permit 01050919 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-07-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-02 |
Time |
17:48 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-13 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-13 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-12 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-12 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2001-06-12 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CLARIFY ALL CONTINUOUS | | | LOADS AT 125%. PER 230-42 AND 215-3 | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | PLEASE NOTE THAT THE AIC RATING WAS | | | SHOWN FOR PANEL BUT NOT FOR MAIN. | | | | | | 3) PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. PLEASE CLARIFY. | | | | | | 4) PLEASE CLARIFY EQUIPMENT GROUNDING | | | METHOD BETWEEN FIRST MEANS OF DISCONNECT | | | AND PANEL(S). EQUIPMENT GROUNDING | | | CONDUCTORS ARE TO BE SIZED BY 250-122. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-22 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-22 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | 1) INTERIOR FINISH IN EXITS SHALL BE | | | CLASS A OR B. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-12-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-10 |
Time |
15:48 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-12-10 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-08-14 |
Time |
13:25 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-08-14 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-06-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-14 |
Time |
08:21 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-06-14 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2001-06-14 00:00:00 | ********************DENIED************** | | | | | | | | | PLEASE PROVIDE OUTSIDE AIR CALCULATIONS | | | AS PER ASHRAE 62-89. | | | | | | PLEASE PROVIDE AIR BALANCE SCHEDULE FOR | | | COMPLIANCE WITH 1997 SMC 501.2. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT.8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-08-09 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-08-14 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-14 00:00:00 | PER PES PROVISO SEE PLANS LS 8/14/01 | | 2001-08-09 00:00:00 | PLUMBING PLAN REVIEW, PROVISO. | | | SHT B5-2 MIN HGTH ON D/F 27" AFF. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-06-12 |
Time |
08:46 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-27 00:00:00 | PLUMBING PLAN REVIEW"DENIED" | | | SPC 94 TAB 407, 1 D/F REQ. | | | END OF COMMENTSPAUL SCHMITZ | | | QUESTIONS 561-659-8096X 8233 |
|
|
|