Plan Review Details - Permit 01050623
| Plan Review Stops For Permit 01050623 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-08-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-02 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-02 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2001-08-02 00:00:00 | 1) MONITORING OF THE FIRE ALARM AND | | | FIRE SPRINKLER SYSTEM ARE NOT OPTIONAL. | | | BOTH SYSTEMS MUST BE MONITORED BY A | | | LICENSED UL LISTED CENTRAL STATION | | | APPROVED BY THE FIRE RESCUE DEPARTMENT. | | | 2) COMBINATION BURGLAR AND FIRE ALARM | | | SYSTEMS ARE TO MEET NFPA 72 REQUIREMENTS | | | 2-4.7.2 | | | 3) DUCT SMOKE DETECTORS WHEN ACTIVATED | | | SHALL AUTOMATICALLY SHUT DOWN AIR | | | HANDLING UNITS AND CAUSE THE FIRE ALARM | | | SYSTEM TO SOUND. | | | 4) SMOKE DETECTORS SHALL BE LOCATED | | | FARTHER THAN THREE FEET FROM AIR | | | CONDITIONER DIFFUSERS. | | | 5) LOCKS ON EXIT DOORS SHALL BE FAIL | | | SAFE AND NOT FAIL SECURE. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096, EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-07-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-07-25 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-07-25 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-06-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-06-05 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-06-05 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2001-06-05 00:00:00 | 1) PLANS NOT SIGNED AND SEALED. ONLY ONE | | | SET OF DRAWINGS PROVIDED. NO CUT SHEETS | | | OR BOOKLETS PROVIDED. | | | | | | ACCORDING TO RUSS GRANT, THE VALUE OF | | | THE FIRE ALARM SYSTEM IS APPROXIMATELY | | | 20,000 DOLLARS. HE WAS ADVISED OF THE | | | PROBLEMS WITH THE PLANS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-05-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-14 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-14 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2001-05-14 00:00:00 | 1) PLANS NOT SIGNED AND SEALED. PLANS | | | CONTAINS ARCHITECTS TITLE BLOCK. | | | 2) FIRE ALARM AND SPRINKLER SYSTEM TO | | | BE MONITORED BY A LICENSED UL LISTED | | | CENTRAL STATION APPROVED BY THE FIRE | | | RESCUE DEPARTMENT. | | | 3) PERMIT APPLICATION INDICATES BURGLAR | | | ALARM AND VEHICLE ENTRY CONTROL BUT | | | ONLY PLANS FOR FIRE ALARM EQUIPMENT IS | | | SHOWN. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
|