Plan Review Details - Permit 01050459
Plan Review Stops For Permit 01050459
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-06-05 Cont ID  
Sent By hpiskura Date 2001-06-05 Time 10:14 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-10-11 Cont ID  
Sent By dpalmer Date 2001-10-11 Time 06:53 Rev Time 0.00
Received By dpalmer Date 2001-10-11 Time 06:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-07-05 Cont ID  
Sent By dpalmer Date 2001-07-05 Time 18:41 Rev Time 0.00
Received By dpalmer Date 2001-07-05 Time 18:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-06 Cont ID  
Sent By dpalmer Date 2001-06-06 Time 16:20 Rev Time 0.00
Received By dpalmer Date 2001-06-06 Time 16:20 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-06-06 Cont ID  
Sent By lsmith Date 2001-06-06 Time 11:53 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-05-15 Cont ID  
Sent By mcarsill Date 2001-05-15 Time 13:17 Rev Time 0.00
Received By mcarsill Date 2001-05-15 Time 13:17 Sent To  
Notes
2001-05-15 00:00:001) INTERIOR FINISH TO BE AT LEAST CLASS
 "C" ON WALLS AND CEILINGS.
 2) FIRE ALARM NOTES INDICATES THAT FIRE
 ALARM CIRCUITS TO BE CLASS B, STYLE C.
 ONLY CLASS A, STYLE D CIRCUITS WILL
 BE PERMITTED.
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER REMODEL.
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM EQUIPMENT INSTALLATION.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-07-30 Cont ID  
Sent By pkrauss Date 2001-07-30 Time 11:54 Rev Time 0.45
Received By pkrauss Date 2001-07-30 Time 11:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-07-05 Cont ID  
Sent By pkrauss Date 2001-06-29 Time 07:39 Rev Time 0.40
Received By pkrauss Date 2001-06-29 Time 07:39 Sent To  
Notes
2001-06-29 00:00:00REVISION - ADDED 2 HEAT PUMPS THAT LOOK
 TO BE SERVING AN AREA LABLED
 "NO WORK IN THIS AREA".
 CALL ARCHITECT DANNY BROWN.
  
 TALKED WITH DANNY BROWN, TWO NEW HEAT
 PUMPS SERVE COMMON AREA.DUCT IS BEING
 RUN UP TO FIRE DAMPERS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-04 Cont ID  
Sent By pkrauss Date 2001-06-04 Time 11:24 Rev Time 0.35
Received By pkrauss Date 2001-06-04 Time 10:58 Sent To  
Notes
2001-06-04 00:00:00*******************PROVISO**************
  
 AHU(S) 2, 3 AND 4 HAVE MORE CFM'S BEING
 DISTRIBUTED (DWG M2.1) THAN IS INDICATED
 ON THE HEAT PUMP SCHEDULE (DWG M0.1).
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT.8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-07-29 Cont ID  
Sent By pschmitz Date 2001-07-29 Time 14:32 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-07-29 00:00:00PLUMBING PLAN REVIEW,PROVISO
 SHT P0-1PLACEMENT OF WATER HAMMER
 ARRESTORS AS PER MFG, INSTRUCTIONS.
 PDI-WH102,NOT AT HIGH POINT.
 QUESTIONS PAUL SCHMITZ 561-659-8096
 X 8233.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-29 Cont ID  
Sent By kstevens Date 2001-07-09 Time 11:53 Rev Time 1.50
Received By pschmitz Date 2001-07-09 Time 11:53 Sent To  
Notes
2001-07-09 00:00:00DENIED
  
 1) PAGE A-1, STILL DO NOT HAVE CLEAR
 FLOOR SPACE FOR LOUNGE SINK. 30" X 48"
 REQUIRED. IF FRONT APPROACH, 30" X 19"
 CLEAR UNDER COUNTER REQUIRED. SHOW
 DETAIL.
  
 2) PAGE A-1, MEN & WOMENS RESTROOMS,
 5' TURNING RADIUS REQUIRED OUTSIDE OF
 STALL. DOORS CAN NOT OPEN INTO CLEAR
 FLOOR SPACE.
  
 3) PAGE PO-1 DOMESTIC WATER RISER DIA-
 GRAM, WATER HAMMER ARRESTORS MUST BE IN-
 STALLED PER MANUFACTURE INSTALLATION IN-
 STRUCTIONS. PLEASE SEE ATTACHED SHEET.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-29 Cont ID  
Sent By pschmitz Date 2001-06-09 Time 12:15 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-06-09 00:00:00PLUMBING PLAN REVIEW"DENIED"
 (1) SHT A1 COMPLY W/FACBC 97,4.1.6(1)(B)
 ACCESSIBLE BUILDING ALTERATIONS.
 (2) SHT A4 REST RM 121 & 122,DETAIL#5,10
 H/C,W/C,DIMENSION OFF WALL 19",FACBC 97
 COMLPY WITH FIG 28, 18" OFF THE WALL.
 (3) SHT A4,RM 121 LAVATORIES, MIRRORS,
 COMPLY W/FACBC 97 SEC 4.19.
 URINALS COMPLY W/FACBC SEC 4.18.2 & .3
 HGTH TO LIP OF URI 17" TO FF. CLEAR FLR
 SPACE,30" X 48".
 (4) SHT P0.1,DOMESTIC WATER ISOMETRIC &
 NOTES 13,18, REFERENCE, AIR CHAMBERS.
 SHOW A DETAIL OF AN APPROVED AIR CHAMBER
 AND HOW IT WILL BE ACCESSIBLE,RECHARGE-
 ABLE. SPC 94 SEC 607.8.3
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status N Date 2001-06-06 Cont ID  
Sent By lsmith Date 2001-06-06 Time 11:54 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***