Plan Review Details - Permit 01050453
Plan Review Stops For Permit 01050453
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-10-12 Cont ID  
Sent By lmartine Date 2001-10-12 Time 17:46 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2001-08-21 00:00:00 
 BUILDING COMMENTS
 -----------------
  
 PROVISO.
  
 1]
 ORIGINAL PLAN REVIEW FEE OF $250.00 HAS
 NOT BEEN PAID.
 2]
 HAVE SOMEONE INSERT REVISED PAGES TO
 MAKE TWO COMPLETE PACKAGES FOR FINAL
 PERMITTING.
 3]
 LICENSED CONTRACTORS SHALL APPLY FOR
 APLLICABLE PERMITS. [BLDG. ELECT.
 PLUMB. AND ROOFING]
 4]
 PLANS SHALL BE REVIEWED BY PALM BEACH
 COUNTY IMPACT FEE OFFICE, SUBMIT COPY
 OF PAID RECEIPT.
  
  
 PLANS REVIEWED BY:
 LUIS MARTINEZ
 561-659-8096
 #8456

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-05-29 Cont ID  
Sent By lmartine Date 2001-05-29 Time 17:46 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-05-29 00:00:00 
 PROVISO
 ---------
  
 MINIMUM ROOF SLOPE 1/4 INCH/FT,
 1503.1.2.3, 1997 SBC
  
 REVIEWED BY:
 L.MARTINEZ

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-20 Cont ID  
Sent By dpalmer Date 2001-08-20 Time 21:28 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 21:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-05-15 Cont ID  
Sent By dpalmer Date 2001-05-15 Time 07:29 Rev Time 0.00
Received By dpalmer Date 2001-05-15 Time 07:29 Sent To  
Notes
2001-05-15 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE CLARIFY PANEL LOCATION.
 PLANS REFERENCE TO CIRCUIT GOING TO
 PANEL?
  
 2)NOTE: PLEASE NOTE THAT MEANS OF DISC-
 -CONNECT FOR POWER IS REQ`D AT DETACHED
 STRUCTURE. PER 225.31 THIS CAN BE AS
 LITTLE AS A SINGLE POLE SWITCH IF ONLY
 ONE CIRCUIT? PLEASE SHOW.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-05-29 Cont ID  
Sent By lmartine Date 2001-05-29 Time 17:57 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-05-14 Cont ID  
Sent By mcarsill Date 2001-05-14 Time 15:38 Rev Time 0.00
Received By mcarsill Date 2001-05-14 Time 15:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-29 Cont ID  
Sent By lmartine Date 2001-05-29 Time 17:58 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-08-21 Cont ID  
Sent By lmartine Date 2001-08-21 Time 13:10 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-05-31 00:00:00PLUMBING PLAN RVIEWPROVISO
 SEE SHT A3 LICENSED PLUMBING CONTRACTOR
 REQUIRED.PES

Review Stop Z ZONING
Rev No 1 Status N Date 2001-05-29 Cont ID  
Sent By lmartine Date 2001-05-29 Time 17:58 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy