Plan Review Details - Permit 01050040
| Plan Review Stops For Permit 01050040 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-24 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-24 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-05-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-10 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-10 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2001-05-10 00:00:00 | ****************** UNSAT ************** | | | | | | 1)NOTE: PLEASE CLARIFY MEANS OF EGRESS | | | LIGHTING FOR LIVING ROOM PER 210-70. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 3) PLEASE CLARIFY EQUIPMENT GROUNDING | | | METHOD BETWEEN FIRST MEANS OF DISCONNECT | | | AND PANEL(S). EQUIPMENT GROUNDING | | | CONDUCTORS ARE TO BE SIZED BY 250-122. | | | | | | 4) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-08 |
Time |
13:06 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-02-08 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2002-02-08 00:00:00 | | | | MECH PERMIT 01050069 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2001-11-21 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-05-07 |
Time |
19:07 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2001-05-07 |
Time |
19:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-06-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-06-25 |
Time |
10:06 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2001-06-25 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-05-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-05-02 |
Time |
11:49 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-05-02 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-07-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-07-03 |
Time |
10:24 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-05-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-05-29 |
Time |
13:15 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-29 00:00:00 | LEA SMITH, PLAN REVIEWER | | | 659-8096 EXT 8394 | | | | | | 1. BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALMBEACH CO.,THE PERMIT PLANS STAMPED | | | BY THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. | | | 2. NEED PRODUCT APPROVAL FOR FRONT DOOR | | | WITH SIDE LITES. | | | 3. DETAILS ON PRIVACY WALL NOT SHOWN ON | | | SITE PLAN AS PER NOTED ON A-2.NOTE: | | | PRIVACY WALL FOOTER CAN NOT ENCROACH ON | | | ADJOINING PROPERTY (ZERO LOT LINE) | | | 4. A NOTICE OF COMMENCMENT MUST BE | | | FILED AT PBC AND A COPY SUBMITTED | | | BEFORE PERMIT IS ISSUED. | | | 5. NEED DESIGN CERTIFICATION FORM | | | COMPLETED. | | | 6. PLANS SHOWS OPTIONAL BBQ.NEED MFGR | | | SPECS ON UNIT AND UL LISTING. | | | 7. RADON FEES OF $42.24 PER ATTACHED BZ | | | REC.#185701 TO BE PAID. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | | LEA AT THE EXTENSION SHOWN ABOVE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-05-22 |
Time |
14:15 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-22 00:00:00 | PER SG 5/22/01 |
|
|
|