Plan Review Details - Permit 01050031
| Plan Review Stops For Permit 01050031 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2001-05-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-08 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-05-08 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2001-05-08 00:00:00 | PASSED WITH PROVISOS: | | | 1. ANY WORK WITHIN PUBLIC R.O.W REQUIRES | | | A SEPARATE PERMIT THROUGH OFFICE OF CITY | | | ENGINEER, RECHARD PITTMAN, 100045TH | | | STREET WEST PALM BEACH, FL 33407 | | | 2. PLEASE SUBMITT TWO SETS OF PLANS TO | | | PUBLIC UTILITIES ENGINEERING SERVICES | | | FOR THIER REVIEW AND ACTUAL CONNECTION, | | | 1000 45TH STREET WEST PALM BEACH, FL | | | 33407. | | | ANY QUESTION PLEASE CONTACT 561-659-8096 | | | EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-05-01 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-01 |
Time |
13:46 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-05-01 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2001-05-01 00:00:00 | FAILED: | | | 1. WE CONCUR WITH REVIEW COMMENT # 1,2 | | | MADE BY CAPTAIN MIKE CARSILLO (FIRE | | | SPRINKER REVIEW STOP), BACKFLOW | | | PREVENTERS SHOULD BE LOCATED AS CLOSE AS | | | POSSIBLE TO THE SOURCE, PREFERABLY ON | | | BACK OF SIDEWALK AND ON PROPERTY. | | | IF ANY QUESTION PLEASE CONTACT 561-659- | | | 8096 EXT. 8492 |
|
|
| Review Stop |
FS |
|
| Rev No |
2 |
Status |
P |
Date |
2001-05-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-08 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-08 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FS |
|
| Rev No |
1 |
Status |
F |
Date |
2001-05-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-01 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-01 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2001-05-01 00:00:00 | 1) THE BACKFLOW DEVICE SHOWN ON THE | | | PLANS IS IN THE INCORRECT LOCATION. | | | THE UTILITIES DEPARTMENT REQUIRED THAT | | | THE BACKFLOW DEVICE BE INSTALLED ON THE | | | EAST SIDE OF THE BUILDING NEAR PINEWOOD | | | AVENUE. | | | 2) NO TAMPER SWITCHES, CHAINS OR LOCKS | | | SHOWN FOR THE BACKFLOW DEVICE. | | | 3) THE FIRE LINE THAT IS TO BE INSTALLED | | | IS TO BE LISTED FOR FIRE PROTECTION | | | SERVICE AND MEET THE REQUIREMENTS OF | | | NFPA 24. | | | 4) FIRE SPRINKLER SYSTEM IS TO BE | | | SUPERVISED BY A LICENSED CENTRAL STATION | | | APPROVED BY THE FIRE RESCUE DEPARTMENT. | | | 5) NO SPARE HEAD BOX SHOWN. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
|