Plan Review Details - Permit 01050024
Plan Review Stops For Permit 01050024
Review Stop E ELECTRICAL
Rev No 1 Status N Date 2001-05-07 Cont ID  
Sent By dpalmer Date 2001-05-07 Time 15:47 Rev Time 0.00
Received By dpalmer Date 2001-05-07 Time 15:47 Sent To  
Notes
2001-05-07 00:00:00*********** NOT REVIEWED *************
  
 1)NOTE: PLEASE NOTE THAT ALL THE ELECTRI
 CAL WAS CROSSED OUT ON ELEC FLOOR PLAN.
 NO REVIEW WAS DONE.
 PLEASE SUBMIT ELECTRICAL PLAN WITH
 PERMIT APPLICATION WHICH WILL BE REQ`D.
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-21 Cont ID  
Sent By pkrauss Date 2001-05-21 Time 12:15 Rev Time 0.35
Received By pkrauss Date 2001-05-21 Time 12:15 Sent To  
Notes
2001-05-21 00:00:00 
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE PLANS WITH
 PERMIT APPLICATION
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-28 Cont ID  
Sent By jleech Date 2001-07-28 Time 09:32 Rev Time 0.33
Received By jleech Date 2001-07-28 Time 09:31 Sent To  
Notes
2001-07-28 00:00:00PLUMBING ONLY. GAS MUST BE INSTALLED BY
 A LICENSED CONTRACTOR. SUBMIT PLANS WITH
 APPLICATION.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-18 Cont ID  
Sent By kstevens Date 2001-05-02 Time 10:47 Rev Time 0.33
Received By kstevens Date 2001-05-18 Time 08:16 Sent To  
Notes
2001-05-18 00:00:00REVIEW NOTES:FALIED
  
 FURNISH COMBUSTION AIR CALCULATIONS,
 ROOM SIZE, AND TOTAL BTU'S FOR ALL GAS
 APPLIENCES IN ROOM WITH DRYER AND WATER
 HEATER.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-07-30 Cont ID  
Sent By rmcdouga Date 2001-07-30 Time 13:29 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-30 00:00:00*************BUILDING UNSAT*************
  
 1) SAME COMMENTS AS FIRST REVIEW ON
 5-21-01.
 PLEASE ADDRESS ALL ITEMS LISTED ON FIRST
 REVIEW.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 ME.
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-05-21 Cont ID  
Sent By rmcdouga Date 2001-05-21 Time 08:32 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-05-21 00:00:00*************BUILDING UNSAT*************
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
 SBC 104.2.2
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) PROVIDE ENERGY CALCULATIONS FOR NEW
 ADDITION PER 97 FLORIDA ENERGY CODE FOR
 BUILDING CONSTRUCTION. IF ADDITION IS
 NOT HEATED OR COOLED IT MUST BE FULLY
 SEPARATED FROM THE CONDITIONED AREA BY
 WALLS AND DOORS (WHICH COMPLY) IN ORDER
 TO BE EXEMPT.
  
 4)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ROOFING MATERIALS FOR FLAT ROOF
 (HOT MOPPED)
  
 5) PROVIDE KEY PLAN, INSTALLATION
 SCHEDULE AND INDICATE WHICH HURRICANE
 SHUTTER DESIGN #S 1-5 YOU WILL BE USING.
 PLEASE SUBMIT (2) COPIES OF THE
 APPROPRIATE METHOD BEING USED.
  
 6) PROVIDE BUCK INSTALLATION/ATTACHMENT
 DETAILS FOR EXTERIOR WINDOW AND DOORS.
  
 7) THE WIND ENGINEERING/STRUCTURAL
 NOTESBY TURQUOISE, INC. LISTS ASCE 7-98
 WHICHIS NOT THE ACCEPTED DESIGN
 CRITERIA FOR THE CITY OF WEST PALM
 BEACH. THESE NOTESAND THE PLANS ARE
 REQUIRED TO BE SIGNED,SEALED AND DATED
 BY THE ENGINEER OF
 RECORD.
  
 8) PLEASE INDICATE THE BATHROOM DOOR
 SIZES ON THE PLANS ; AT LEAST ONE BATH-
 ROOM DOOR MUST HAVE A 29" CLEAR OPENING
 PER 97 FLORIDA ACCESSIBILITY CODE.
  
 9) PROVIDE SAFTEY GLAZING IN BATHROOM
 WINDOW IF LESS THAN 60" ABOVE DRAIN
 INLET OF BATH TUB. 97 SBC 2405.2.1
  
 10) THE LOCATIONS OF CONCRETE COLUMNS
 AND REINFORCED FILLED CELLS DO NOT MATCH
 ON FLOOR PLAN AND FOUNDATION PLAN.
 PLEASE CORRECT.
  
 IF YOU HAVE QUESTIONS CALL ME.
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-15 Cont ID  
Sent By sgraham Date 2001-05-15 Time 14:32 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***