Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-06-14 Cont ID  
Sent By dpalmer Date 2001-06-14 Time 19:31 Rev Time 0.00
Received By dpalmer Date 2001-06-14 Time 19:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-04-30 Cont ID  
Sent By dpalmer Date 2001-04-30 Time 19:22 Rev Time 0.00
Received By dpalmer Date 2001-04-30 Time 19:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-08 Cont ID  
Sent By hmoser Date 2001-10-08 Time 11:57 Rev Time 0.33
Received By hmoser Date 2001-10-08 Time 11:57 Sent To  
Notes
2001-10-08 00:00:00CALLED FOR PICK UP 10/8/01 BOX AH.M.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-05-01 Cont ID  
Sent By hmoser Date 2001-05-01 Time 07:41 Rev Time 0.33
Received By hmoser Date 2001-04-28 Time 11:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-27 Cont ID  
Sent By jleech Date 2001-11-27 Time 20:24 Rev Time 0.33
Received By jleech Date 2001-11-27 Time 20:24 Sent To  
Notes
2001-11-27 00:00:00REVISED RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-04-27 Cont ID  
Sent By kstevens Date 2001-04-27 Time 08:29 Rev Time 0.33
Received By kstevens Date 2001-04-27 Time 08:29 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-06-18 Cont ID  
Sent By rmcdouga Date 2001-06-18 Time 12:08 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-06-18 00:00:00************BUILDING PROVISO************
  
 1) THE DOOR TO ALTERNATE BEDROOM (DEN)
 ON SHEET A-1.0 MUST COMPLY WITH THE
 FAIR HOUSING ACT AND PROVIDE A 32" CLEAR
 OPENING, IF THIS OPTION IS USED.
  
 2)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ROOFING MATERIALS USED ON FLAT AREAS
 OF ROOF
  
 3) PROVIDE KEY PLAN FOR STORM PANELS
 PRIOR TO INSTALLATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-05-08 Cont ID  
Sent By rmcdouga Date 2001-05-08 Time 14:34 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-05-09 00:00:00*************BUILDING UNSAT*************
  
 1) SURVEY AND PLANS SUBMITTED DO NOT
 CONCUR. PLEASE REVIEW AND SUBMIT REVISED
 DOCUMENTS.
  
 2) PROVIDE ATTIC ACCESS IF CLEAR HEIGHT
 OF ATTIC IS 24" OR MORE PER 2309.6 OF
 THE 97 SBC. INDICATE LOCATION AND SIZE
 OF ACCESS OPENING ON PLANS OR INDICATE
 ON PLANS THAT CLEAR HEIGHT OF ATTIC IS
 LESS THAN 24".
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - ROOFING MATERIAL FOR FLAT ROOF
  
 4) SHEET S1 DOES NOT INDICATE ADEQUATE
 CONNECTOR FOR TRUSS TG1 ( 1457#S UPLIFT)
 ANCHOR TA-15 (1400#S UPLIFT) IS SHOWN
 FOR TRUSSES T2 & T3 WHICH HAVE UPLIFTS
 OF LESS THAN 170#S. PLEASE REVIEW TURRET
 DIMENSIONS AND CORRECT PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2001-04-24 Cont ID  
Sent By sgraham Date 2001-04-24 Time 11:41 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***