Plan Review Details - Permit 01040885
Plan Review Stops For Permit 01040885
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-06-08 Cont ID  
Sent By hpiskura Date 2001-06-08 Time 08:51 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-07 Cont ID  
Sent By dpalmer Date 2001-06-07 Time 17:59 Rev Time 0.00
Received By dpalmer Date 2001-06-07 Time 17:59 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2001-05-21 Cont ID  
Sent By mamini Date 2001-05-21 Time 15:54 Rev Time 4.00
Received By mamini Date 2001-05-21 Time 15:00 Sent To  
Notes
2001-05-21 00:00:00FAILED:
 1. PLEASE PROVIDE PERVIOUS & IMPERVIOUS
 AREA CALCULATION DUE TO ALL THE PROPOSED
 CHANGES.THE TOTAL AMOUNTS MUST BE
 EQUAL TO 100% OF TOTAL SITE ACRE OR S.F.
 2. PLEASE CLEARLY SHOW DRIVEWAY
 APPROACHES.DRIVEWAY APPROACHES MUST BE
 AT MINIMUM PER CITY STANDARD. SEE
 ATTACHED.
 3. PLEASE PROVIDE STORM WATER
 CALCULATION FOR OUR REVIEW IF YOU HAVE
 NOT SUBMITTED TO JOSE DEL RIO, STORM
 WATER ENGINEER AT 1000 45TH STREET WPB,
 FL 33407 659-8040
 4. PROVIDE POLLUTION PREVENTION PLANS.
 PLAN SHOULD BE INSTALLED IN THE FIELD
 PRIOR TO ANY EARTH WORKS.IT SHOULD BE
 KEPT ON SITE DURING THE CONSTRUCTIONS.
 5. PLEASE SHOW UNDERGROUND UTILITY WORKS
 AND LOCATION OF ALL NEW CROSS CONNEC-
 TIONS TO CITY SERVICES, IF ANY.
 6. ALL BROKEN SIDEWALKS, CURBS(&GUTTERS)
 ALONG THE PROPERTY, ALL SIDES SHOULD BE
 REPLACED.
 7. ALL DRIVEWAYS THAT WILL NOT BE USED
 MUST BE REMOVED AND REPLACED WITH
 REGULAR CURBS(& GUTTERS).
 8. PLEASE STATE WHAT 6'- 0" IS ON WEST
 SIDE OF BUILDING, ADJACENT TO PUBLIC
 ALLEY.
 9. DUMPSTERS MUST BE AT MINIMUM PER CITY
 STANDARDS AND REQUIREMENTS. SEE ATTACHED
 10. PLEASE INDICATE WIDTH OF PUBLIC
 ALLEY IF KNOWN.
 11. PLEASE PROVIDE SIGNING & MARKING FOR
 ENTIRE SITE.
 12. ANY WORK WITHIN PUBLIC R.O.W WILL
 REQUIRE A SEPARATE PERMIT THROUGH
 OFFICE OF CITY ENGINEER.659-8040
 13. ANY NEW CONNECTIONS TO CITY UTILITY
 SERVICES WILL REQUIRE A SEPARATE PERMIT
 THROUGH PUBLIC UTILITY ENGINEERING
 SERVICES.659-8040
 IF ANY QUESTION PLEASE CONTACT 561-659-
 8096 EXT. 8492

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-05-16 Cont ID  
Sent By mcarsill Date 2001-05-16 Time 12:30 Rev Time 0.00
Received By mcarsill Date 2001-05-16 Time 12:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-06-06 Cont ID  
Sent By lsmith Date 2001-06-06 Time 14:44 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-05-29 Cont ID  
Sent By pschmitz Date 2001-05-29 Time 10:51 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-05-29 00:00:00PLUMBING PLAN REVIEW"PROVISO'
 RPZV REQ. ON IRRIGATION WATER SUPPLY,
 DUE TO DEGREE OF HAZARD.
 END OF COMMENTS PAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status F Date 2001-05-16 Cont ID  
Sent By sgraham Date 2001-05-16 Time 07:03 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-05-16 00:00:00DENIED BY JOE MINICOZZI SEE ATTACHED
 LIST