Plan Review Details - Permit 01040732
Plan Review Stops For Permit 01040732
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-04-25 Cont ID  
Sent By dpalmer Date 2001-04-25 Time 20:10 Rev Time 0.00
Received By dpalmer Date 2001-04-25 Time 20:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-08-27 Cont ID  
Sent By pkrauss Date 2001-08-27 Time 07:05 Rev Time 0.30
Received By pkrauss Date 2001-08-27 Time 07:01 Sent To  
Notes
2001-08-27 00:00:00MECH REV 01040741

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-05-04 Cont ID  
Sent By ndenmark Date 2001-05-04 Time 10:33 Rev Time 0.33
Received By ndenmark Date 2001-05-04 Time 10:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-04-25 Cont ID  
Sent By pkrauss Date 2001-04-25 Time 10:53 Rev Time 0.30
Received By pkrauss Date 2001-04-25 Time 10:53 Sent To  
Notes
2001-04-25 00:00:00*******************DENIED***************
  
 EQUIPMENT SCHEDULED FOR AHU-1 INDICATES
 1,000 CFM, THE PLAN SHOWS ONLY 650 CFM
 BEING DISTRIBUTED, PLEASE CORRECT.
  
 EQUIPMENT SCHEDULED FOR AHU-3 IS 1,600
 CFM AND PLANS SHOW ONLY 975 CFM BEING
 DISTRIBUTED.
  
 NO EXHAUST FANS ARE INDICATED ON PLANS,
 AS PER 97 SMC 503.3.1 AIR EXHAUSTED FROM
 BATH, TOILET, COAT ROOM OR SIMILAR ROOMS
 SHALL NOT BE RECIRCULATED, IT SHALL BE M
 ECHANICALLY EXHAUSTED TO OUTDOORS OR SHA
 LL HAVE WINDOWS WITH NO LESS THAN 3 SQ.
 FT. OF OPEN SPACE.
  
 ALSO PLANS INDICATE A FIREPLACE, IF A
 PRE-FAB FIREPLACE IS BEING INSTALLED
 PLEASE PROVIDE MANUFACTURE DETAILS (UL
 LISTING) AND FLUE INFORMATION/DETAILS.

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-04-23 Cont ID  
Sent By kstevens Date 2001-04-19 Time 18:42 Rev Time 0.33
Received By kstevens Date 2001-04-23 Time 07:57 Sent To  
Notes
2001-04-19 00:00:00PLUMBING PLAN REVIEW
 SPC - 94
 RISER DIAGRAM NOT TO CODE.
 PLUMBING CONTRACTOR TO SUBMIT RISER
 DIAGRAM WITH PLUMBING PERMIT APPLICATION
  
  
 PLAN REVIEW BY KEN STEVENS
 (561) 659-8096 X'S 8389/8377

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-05-04 Cont ID  
Sent By lhatten Date 2001-05-04 Time 18:43 Rev Time 4.00
Received By lhatten Date 2001-04-28 Time 22:38 Sent To  
Notes
2001-05-04 00:00:00CALC. FEES&PRINT CARDS 05/04/2001
2001-04-30 00:00:00REVIEW & STAMP PLANS04/28/2001

Review Stop Z ZONING
Rev No 1 Status P Date 2001-04-19 Cont ID  
Sent By sgraham Date 2001-04-19 Time 10:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***