Plan Review Details - Permit 01040732
| Plan Review Stops For Permit 01040732 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-25 |
Time |
20:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-25 |
Time |
20:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-08-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-27 |
Time |
07:05 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-08-27 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2001-08-27 00:00:00 | MECH REV 01040741 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-05-04 |
Time |
10:33 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-05-04 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-25 |
Time |
10:53 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-04-25 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2001-04-25 00:00:00 | *******************DENIED*************** | | | | | | EQUIPMENT SCHEDULED FOR AHU-1 INDICATES | | | 1,000 CFM, THE PLAN SHOWS ONLY 650 CFM | | | BEING DISTRIBUTED, PLEASE CORRECT. | | | | | | EQUIPMENT SCHEDULED FOR AHU-3 IS 1,600 | | | CFM AND PLANS SHOW ONLY 975 CFM BEING | | | DISTRIBUTED. | | | | | | NO EXHAUST FANS ARE INDICATED ON PLANS, | | | AS PER 97 SMC 503.3.1 AIR EXHAUSTED FROM | | | BATH, TOILET, COAT ROOM OR SIMILAR ROOMS | | | SHALL NOT BE RECIRCULATED, IT SHALL BE M | | | ECHANICALLY EXHAUSTED TO OUTDOORS OR SHA | | | LL HAVE WINDOWS WITH NO LESS THAN 3 SQ. | | | FT. OF OPEN SPACE. | | | | | | ALSO PLANS INDICATE A FIREPLACE, IF A | | | PRE-FAB FIREPLACE IS BEING INSTALLED | | | PLEASE PROVIDE MANUFACTURE DETAILS (UL | | | LISTING) AND FLUE INFORMATION/DETAILS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-04-19 |
Time |
18:42 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-04-23 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2001-04-19 00:00:00 | PLUMBING PLAN REVIEW | | | SPC - 94 | | | RISER DIAGRAM NOT TO CODE. | | | PLUMBING CONTRACTOR TO SUBMIT RISER | | | DIAGRAM WITH PLUMBING PERMIT APPLICATION | | | | | | | | | PLAN REVIEW BY KEN STEVENS | | | (561) 659-8096 X'S 8389/8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2001-05-04 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2001-05-04 |
Time |
18:43 |
Rev Time |
4.00 |
| Received By |
lhatten |
Date |
2001-04-28 |
Time |
22:38 |
Sent To |
|
|
| Notes |
| 2001-05-04 00:00:00 | CALC. FEES&PRINT CARDS 05/04/2001 | | 2001-04-30 00:00:00 | REVIEW & STAMP PLANS04/28/2001 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-04-19 |
Time |
10:13 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|