Plan Review Details - Permit 01040729
| Plan Review Stops For Permit 01040729 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-25 |
Time |
19:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-25 |
Time |
19:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-08-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2001-08-04 |
Time |
10:00 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2001-08-04 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2001-08-04 00:00:00 | REVISION OK BY H. MOSER CALLED APOLL A/C | | | FOR PICKUP PLANS IN BOX A 8/4/01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-05-04 |
Time |
10:34 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-05-04 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-24 |
Time |
16:38 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-04-24 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2001-04-24 00:00:00 | *******************DENIED*************** | | | | | | | | | NO EXHAUST FANS ARE INDICATED ON PLAN | | | FOR BATHROOMS , THIS AIR SHALL NOT BE | | | RECIRCULATED AS PER 1997 SMC 503.3.1. | | | AIR WITHIN A BATHROOM SHALL BE | | | MECHANICALLY EXHAUSTED OR SHALL HAVE | | | WINDOWS WITH NO LESS THAN 3 SQ FT OF | | | OPEN SPACE. | | | | | | EQUIPMENT SCHEDULE FOR AHU 1 INDICATES | | | 1,000 CFM PLAN ONLY SHOWS 650 CFM WILL | | | THIS CAUSE THE AHU TO SHORT CYCLE? | | | ALSO AHU 3 CFM ON SCHEDULE IS 1,600 AND | | | PLAN INDICATES ONLY 950. | | | | | | ALSO PLANS INDICATE A FIREPLACE - PLEASE | | | PROVIDE INSOFORMATION PERTAINING TO | | | THE EXHAUST FLUE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-04-19 |
Time |
19:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-04-23 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2001-04-19 00:00:00 | PLUMBING PLAN REVIEWSPC - 94 | | | DENIED | | | RISER DIAGRAM NOT TO CODE. | | | PLUMBING CONTRACTOR TO SUBMIT RISER | | | DIAGRAM WITH PLUMBING PERMIT APPLICATION | | | | | | PLAN REVIEW BY KEN STEVENS | | | (561) 659-8096 X'S 8389/8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2001-05-04 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2001-05-04 |
Time |
19:00 |
Rev Time |
4.00 |
| Received By |
lhatten |
Date |
2001-05-03 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2001-05-04 00:00:00 | REVIEW & STAMP PLANS 05/04/2001 | | | CALC. FEES&PRINT CARDS 05/04/2001 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-04-19 |
Time |
10:11 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|