Plan Review Details - Permit 01040482
Plan Review Stops For Permit 01040482
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2001-10-01 Cont ID  
Sent By jwitmer Date 2001-10-01 Time 13:21 Rev Time 1.00
Received By jwitmer Date 2001-10-01 Time 13:17 Sent To  
Notes
2001-10-01 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01040482
 BLDG "D"
 617 EXECUTIVE CENTER DR
  
  
 REVISIONS SAME AS 01040482

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-08-12 Cont ID  
Sent By jwitmer Date 2001-08-12 Time 11:12 Rev Time 1.50
Received By jwitmer Date 2001-08-12 Time 11:12 Sent To  
Notes
2001-08-12 00:00:00BUILDING PLAN REVIEW
 PERMIT# 01040482
 617 EXECUTIVE CENTER DRIVE
  
 REVISION #1
  
 COMMENTS ARE THE SAME AS PREMIT 01040479

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-20 Cont ID  
Sent By jwitmer Date 2001-05-18 Time 11:33 Rev Time 0.00
Received By jwitmer Date 2001-07-20 Time 11:36 Sent To  
Notes
2001-07-20 00:00:00APPROVED PER JIM WITMER
2001-05-18 00:00:00BUILDING PLAN REVIEW
 PLAN CHECK # 01040482
 617 EXECUTIVE CENTER DR
 BUILDING:D (4 STORY)
  
  
 SEE PLAN CHECK FOR NOTES 01040479

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-05-07 Cont ID  
Sent By jwitmer Date 2001-05-07 Time 17:51 Rev Time 0.00
Received By jwitmer Date 2001-05-07 Time 11:37 Sent To  
Notes
2001-05-07 00:00:00BUILDING PLAN CHECK
 PLAN CHECK 01040482
 617 EXECUTIVE CENTER DRIVE
 BUILDING: D (4 STORY)
  
 COMMENTS ARE THE SAME AS FOR PERMIT
 01040479.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-29 Cont ID  
Sent By dpalmer Date 2001-10-29 Time 17:58 Rev Time 0.00
Received By dpalmer Date 2001-10-29 Time 17:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-05-18 Cont ID  
Sent By dpalmer Date 2001-05-18 Time 14:16 Rev Time 0.00
Received By dpalmer Date 2001-05-18 Time 14:16 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-05-24 Cont ID  
Sent By mamini Date 2001-05-24 Time 08:37 Rev Time 1.00
Received By mamini Date 2001-05-24 Time 08:37 Sent To  
Notes
2001-05-24 00:00:00PASSED :
 1. SEE PERMIT NUMBER 01030517 FOR REVIEW
 COMMENTS.
 IF ANY QUESTIONS PLEASE CONTACT 561-659-
 8096 EXT. 8492

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-05-23 Cont ID  
Sent By mcarsill Date 2001-05-23 Time 16:28 Rev Time 0.00
Received By mcarsill Date 2001-05-23 Time 16:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-05-18 Cont ID  
Sent By mcarsill Date 2001-05-18 Time 13:21 Rev Time 0.00
Received By mcarsill Date 2001-05-18 Time 13:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-05-03 Cont ID  
Sent By mcarsill Date 2001-05-03 Time 09:45 Rev Time 0.00
Received By mcarsill Date 2001-05-03 Time 09:45 Sent To  
Notes
2001-05-03 00:00:001) ALL UNDERGROUND FIRE MAINS ARE TO BE
 LISTED FOR FIRE PROTECTION SERVICE AND
 COMPLY WITH NFPA 24, FIRE SERVICE MAINS
 AND THEIR APPURTENANCES.
 2) INGRESS AND EGRESS INTO THE COMPLEX
 SHALL BE A MINIMUM OF TWENTY FEET IN
 CLEAR WIDTH. BATTERY BACK-UP FEATURE
 SHALL BE PROVIDED FOR GATE-ARMS SHOULD
 LOSS OF POWER OCCUR. TRAFFIC CALMING
 HUMPS ARE NOT TO INTERFERE WITH FIRE
 RESCUE MOVEMENT INTO THE COMPLEX.
 3) BUILDING LETTERS A,B,C AND D, ARE TO
 BE PLACED ON THE BUILDING SINCE IT
 APPEARS TO BE A SINGLE ADDRESS FOR THE
 APARTMENT COMPLEX.
 4) AT LEAST ONE STAIR IS TO BE PROVIDED
 DURING CONSTRUCTION. TEMPORARY
 STANDPIPES ARE REQUIRED IN ALL BUILDINGS
 UNDER CONSTRUCTION WHEN THEY ARE
 REQUIRED TO HAVE STANDPIPE SYSTEMS.
 5) HOW IS THE COMBUSTIBLE LINT REMOVED
 FROM THE DRYER CHASE. NO ACCESS PANELS
 HAVE BEEN PROVIDED.
 6) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE INSTALLATIONS OF THE FIRE
 SPRINKLER SYSTEMS. NO HYDRAULIC
 CALCULATIONS PROVIDED WITH FIRE
 SPRINKLER DRAWINGS. STANDPIPE SYSTEMS
 REQUIRED IN ALL BUILDINGS THREE STORIES
 AND MORE THAN FIFTY IN HEIGHT. ALL
 VERTICAL SHAFTS ARE TO BE FIRE
 SPRINKLER PROTECTED. PLEASE EXPLAIN
 RATIONALE FOR THE SINGLE FIRE
 DEPARTMENT CONNECTION SHOWN ON THE
 DRAWINGS.
 7) DOOR SWINGS IN THE STAIRWELLS ARE TO
 SWING IN THE DIRECTION OF EXIT TRAVEL.
 8) SMOKE DETECTORS WHEN INSTALLED ARE
 TO BE A MINIMUM OF THREE FEET FROM
 AIR CONDITIONER DIFFUSERS.
 9) TRASH CHUTES TO COMPLY WITH NFPA 82,
 THE STANDARD ON INCINERATORS,WASTE AND
 LINEN HANDLING SYSTEMS AND EQUIPMENT.
 10) PLEASE INDICATE PORTABLE FIRE
 EXTINGUISHER LOCATIONS.
 11) SIGNS ARE REQUIRED FOR ALL BUILDINGS
 FOUR OR MORE STORIES. SIGNS SHALL
 INDICATE FLOOR LEVEL, THE IDENTITY OF
 THE STAIR, THE TERMINUS OF THE STAIR,
 TOP AND BOTTOM.
 12) PLEASE INDICATE THE DISTANCES
 BETWEEN THE TRANSFORMER PADS AND THE
 EXITWAYS FROM THE BUILDING.
 13) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE FIRE ALARM SYSTEMS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2002-04-23 Cont ID  
Sent By pkrauss Date 2002-04-23 Time 09:10 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-04-23 00:00:00MECH PERMIT 01071107PLAN UNDER PERMIT
 01040479

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2002-04-15 Cont ID  
Sent By pkrauss Date 2002-04-15 Time 12:16 Rev Time 0.50
Received By pkrauss Date   Time   Sent To  
Notes
2002-04-15 00:00:00PROVISO:MECH PERMIT 01071107
  
 2 COPIES OF ORIGINAL LETTER FOR MONTHLY
 MAINTENANCE FOR THE CLEANING OR THE
 BOOSTER FAN.TWO NOTARIZED LETTERS TO
 FOLLOW.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 09:56 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-03-12 00:00:00SUBMITTAL-LOUVERS FOR THE ELEVATOR SHAFT

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 09:18 Rev Time 1.00
Received By pkrauss Date 2002-03-12 Time 09:18 Sent To  
Notes
2002-03-12 00:00:00********************DENIED**************
  
 MECHANICAL PERMIT 01071107
 CALCULATIONS FOR DRYER EXHAUST
  
 PROVIDE SPECIFIC MANUFACTURER SUBMITTAL
 DATA & PURCHASE ORDER FOR DRYERS.
 DRYERS TO BE INSTALLED AT THE TIME OF
 FINAL INSPECTION.DUCTWORK TO BE
 INSTALLED AS PER SPECIFIC MANUFACTURERS
 INSTRUCTIONS. RESIDENTIAL DRYER
 EXHAUST DUCTS WHICH ARE NOT DESIGNED
 FOR SPECIFIC DRYER SHALL COMPLY WITH
 1997 SMC 509.3.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2002-02-13 Cont ID  
Sent By pkrauss Date 2002-02-08 Time 09:31 Rev Time 0.35
Received By pkrauss Date 2002-02-08 Time 09:31 Sent To  
Notes
2002-02-08 00:00:00 
  
 MECH PERMIT 01071107
  
 LETTER FROM ENGINEER ON BATHROOM EXHAUST
 TERMINATING AT A RATED WALL WHICH IS AN
 EGRESS CORRIDOR.FIRE DAMPERS ARE NOT
 PERMITTED IN DRYER EXHAUST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-05-24 Cont ID  
Sent By pkrauss Date 2001-05-24 Time 07:49 Rev Time 0.20
Received By pkrauss Date   Time   Sent To  
Notes
2001-05-24 00:00:00NOTES UNDER PERMIT 01040480.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-05-24 Cont ID  
Sent By pkrauss Date 2001-05-24 Time 07:48 Rev Time 1.30
Received By pkrauss Date 2001-05-17 Time 11:13 Sent To  
Notes
2001-05-24 00:00:00REVIEW UNDER PERMIT 01040480

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-10 Cont ID  
Sent By pkrauss Date 2001-05-10 Time 11:07 Rev Time 3.00
Received By pkrauss Date 2001-05-10 Time 11:00 Sent To  
Notes
2001-05-10 00:00:00REVIEW NOTES ON PERMIT 01040480.
 THIS SET IS NOT A FULL SET OF AC
 DRAWINGS.

Review Stop P PLUMBING
Rev No 8 Status P Date 2003-01-22 Cont ID  
Sent By kstevens Date 2003-01-22 Time 09:18 Rev Time 0.10
Received By kstevens Date 2003-01-22 Time 09:18 Sent To  
Notes
2003-01-22 00:00:00SUBMITTAL - DOMESTIC BOOSTER PUMP PKG

Review Stop P PLUMBING
Rev No 7 Status P Date 2002-09-26 Cont ID  
Sent By kstevens Date 2002-09-26 Time 10:26 Rev Time 0.00
Received By kstevens Date 2002-09-26 Time 10:26 Sent To  
Notes
2002-09-26 00:00:00REVISION OK - ADD 2 6" OVERFLOW SCUPPERS

Review Stop P PLUMBING
Rev No 6 Status P Date 2001-11-29 Cont ID  
Sent By kstevens Date 2001-11-29 Time 16:03 Rev Time 0.50
Received By kstevens Date 2001-11-29 Time 16:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2001-10-19 Cont ID  
Sent By kstevens Date 2001-10-19 Time 16:23 Rev Time 0.33
Received By kstevens Date 2001-10-19 Time 16:23 Sent To  
Notes
2001-10-19 00:00:00DENIED
  
 SEE COMMENTS FROM PERMIT #01040479
  
 REVEIW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 4 Status F Date 2001-09-28 Cont ID  
Sent By kstevens Date 2001-09-28 Time 14:57 Rev Time 0.33
Received By kstevens Date 2001-09-28 Time 14:56 Sent To  
Notes
2001-09-28 00:00:00DENIED
  
 SEE COMMENTS FROM PERMIT #01040479
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-09-22 Cont ID  
Sent By pschmitz Date 2001-09-22 Time 08:46 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-09-22 00:00:00REVISION, PLUMBING FOUNDATION ONLY.PES

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-24 Cont ID  
Sent By kstevens Date 2001-05-24 Time 07:34 Rev Time 0.25
Received By kstevens Date 2001-05-24 Time 07:34 Sent To  
Notes
2001-05-24 00:00:00REVIEW NOTES ....PASSED....
  
 ....PROVISO...
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO FILED WITH THE DEPARTMENT OF
 CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH. GNI 1 OF 1.
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IS 2 FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIRCHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3
  
 4) PAGE P-4, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISERS, BUT P/T #2 ONLY SHOWS
 A SINGLE RISER. TWO RISERS ARE REQUIRED.
  
 5) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRES THAT SPEC.A OR
 B BE SHOWN ON PLAN.
  
 6) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND. - 98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8389

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-16 Cont ID  
Sent By kstevens Date 2001-05-16 Time 19:22 Rev Time 1.50
Received By kstevens Date 2001-05-17 Time 08:36 Sent To  
Notes
2001-05-16 00:00:00REVIEW NOTES. PASSED...PROVISO...
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO BE FILED WITH THE DEPARTMENT
 OF CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH. GNI 1 0F 1
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IS 2 FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIR CHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3
  
 4) PAGE P-5, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISERS, BUT P/T #2 ONLY SHOWS
 A SINGLE RISER. TWO RISERS ARE REQUIRED.
  
 5) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRES THAT SPEC. A OR
 B BE SHOWN ON PLAN.
  
 6) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND-98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-22 Cont ID  
Sent By sgraham Date 2001-05-04 Time 14:04 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-05-22 00:00:00APPROVED BY ANGELLA VANN
2001-05-04 00:00:00NEED MINOR AMENDENT