Plan Review Details - Permit 01040481
Plan Review Stops For Permit 01040481
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2001-10-29 Cont ID  
Sent By jwitmer Date 2001-10-29 Time 11:11 Rev Time 1.00
Received By jwitmer Date 2001-10-29 Time 11:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2001-10-01 Cont ID  
Sent By jwitmer Date 2001-10-01 Time 13:09 Rev Time 2.00
Received By jwitmer Date 2001-10-01 Time 13:09 Sent To  
Notes
2001-10-01 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01040481
 BLDG "C"
 613 EXECUTIVE CENTER DR
  
  
 SAME COMMENTS AS 01040479

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-08-23 Cont ID  
Sent By jwitmer Date 2001-08-23 Time 16:58 Rev Time 1.00
Received By jwitmer Date 2001-08-23 Time 16:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-20 Cont ID  
Sent By jwitmer Date 2001-05-18 Time 11:54 Rev Time 0.00
Received By sjohnson Date   Time   Sent To  
Notes
2001-07-20 00:00:00APPROVED PER JIM WITMER
2001-05-18 00:00:00BUILDING PLAN REVIEW
 PLAN CHECK # 01040481
 613 EXECUTIVE CENTER DR
 BLDG. "C" 7 STORY
  
 SAME COMMENTS AS PLAN CHECK 01040479
 WITH THE ADDED COMMENT;
  
 THIS BUILDING, A 7 STORY IS TALLER THAN
 60' THEREFORE IT IS A THRESHOLD BUILDING
 THE REQUIREMENTS IN THE ADMINISTRATIVE
 CODE WPB AMENDMENTS 105.3.1 FOR A
 THRESHOLD BUILDING NEED TO SHOW COMPLI-A
 ANCE. THE ENFORCING AGENCY SHALL REQUIRE
 A SPECIAL INSPECTOR TO PERFORM STRUCTUR-
 AL INSPECTIONS ON A THRESHOLD BUILDING
 PURSUANT TO A STRUCTURAL INSPECTION PLAN
 PREPARED BY THE ENGINEER OR ARCHITECT OF
 RECORD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-05-07 Cont ID  
Sent By jwitmer Date 2001-05-07 Time 14:27 Rev Time 2.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-05-07 00:00:00BUILDING PLAN REVIEW
 PLAN CHECK# 01040481
 613 EXECUTIVE CENTER DR
 BLDG. "D"
  
 1)- THE CORRECT ADDRESS FOR THIS BUILD-
 ING WILL BE 613 EXECUTIVE CENTER DR.
  
 2)- SBC AMEND.1804.2.7.2 TEST RPORTS:
 TEST REPORTS HAVE NOT BEEN PROVIDED
  
 3)- THIS BUIDING 7 STORIES IS TALLER
 THAN 60 FT.THEREFORE IT IS A THRESHOLD
 BUILDING ,THE REQUIREMENTS IN 105.3.1
 FOR A THRESHOLD BUILDING WILL NEED TO
 SHOW COMPLIANCE!
 THE ONSITE INSPECTOR WILL NEED TO MEET
 WITH DON NEELY,ASST. BUILDINGOFFICIAL
 BEFORE THE PERMIT MAY BE ISSUED.
  
 4)- THIS BUILDING NEEDS TO SHOW THAT IT
 IS IN COMPLIANCE WITH ASCE 7-95.
  
 5)- COMPONENTS & CLADDING: THERE IS NO
 WINDOW BUCK ATTACHMENT, THE DESIGNER OF
 RECORD WILL NEED TO SUPPLY THE DETAILS
 FOR ALL GLAZED OPENINGS.
  
 6)- CODE REQUIREMENTS THAT REQUIRE
 PRODUCT TESTING CAN BE"PROVISOED" THAT
 THE CONTRACTOR MAY BRING THESE IN LATER,
 THEY RUN THE RISK OF BEING DENIED IF THE
 PRODUCT DOESN' MEET THE STANDARDS SET
 FORTH IN THE CITIES POLICY FOR GLAZED
 OPENINGS.
  
 7)- ROOFING PRODUCT APPROVAL WILL BE RE-
 QUIRED UNDER A SEPERATE PERMIT.
  
 8)- SHEET A2.3 DETAILS FOR THE REFUSE
 SHUTE ARE MISSING THE 2HR. WALL TO PRO-
 TECT THE SHUTE ITSELF.SBC 705.2.4.2.
  
 9)- FL. STATUTE 553.895 REQUIRES FIRE
 SPRINKLER PLANS FOR BUILDINGS USED AS A
 PUBLIC LODGING ESTABLISHMENT.
 SBC 903.7.6.
  
 10)- SHEET 7.0 DETAILS 1 & 3 DEPICT ROOF
 ING BEING ATTACHED TO METAL PERLINS,
 SBC 1503.1.2.2. REQUIRES ALL ROOFING TO
 BE APPLIED TO SOLID OR CLOSELY FITTED
 DECKING OR SHEATHING.AMENDMENTS TO SBC.
  
 11)- SHEET S-5 ANCHOR SCHEDULE FOR METAL
 TRUSSES, GIVE THE MANUFACTURES MODEL
 NUMBER FOR TRUSSES AND ALLOWALBE UPLIFT
 LOADS.
  
 12)- SHEET A7.0 DETAIL 2/3 SHOW A BACK-
 ING MATERIAL THAT THE WIRE LATH ATTACHES
 TO BUT IT ISN'T SPEC'D OUT?
  
 JIM WITMER
 BUILDING PLAN REVIW
 (561) 659 8096 EX 8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-29 Cont ID  
Sent By dpalmer Date 2001-10-29 Time 17:57 Rev Time 0.00
Received By dpalmer Date 2001-10-29 Time 17:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-05-18 Cont ID  
Sent By dpalmer Date 2001-05-18 Time 14:34 Rev Time 0.00
Received By dpalmer Date 2001-05-18 Time 14:34 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-05-24 Cont ID  
Sent By mamini Date 2001-05-24 Time 08:30 Rev Time 1.00
Received By mamini Date 2001-05-24 Time 08:30 Sent To  
Notes
2001-05-24 00:00:00PASSED:
 1. SEE PERMIT NUMBER 01030517 FOR REVIEW
 COMMENTS.
 IF ANY QUESTION PLEASE CONTACT 561-659-
 8096 EXT. 8492

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-05-23 Cont ID  
Sent By mcarsill Date 2001-05-23 Time 16:27 Rev Time 0.00
Received By mcarsill Date 2001-05-23 Time 16:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-05-18 Cont ID  
Sent By mcarsill Date 2001-05-18 Time 13:20 Rev Time 0.00
Received By mcarsill Date 2001-05-18 Time 13:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-05-02 Cont ID  
Sent By mcarsill Date 2001-05-02 Time 11:10 Rev Time 0.00
Received By mcarsill Date 2001-05-02 Time 11:10 Sent To  
Notes
2001-05-02 00:00:001) ALL UNDERGOUND FIRE MAINS ARE TO BE
 LISTED FOR FIRE PROTECTION SERVICE AND
 COMPLY WITH NFPA 24, FIRE SERVICE MAINS
 AND THEIR APPURTENANCES.
 2) INGRESS AND EGRESS INTO THE COMPLEX
 SHALL BE A MINIMUM OF TWENTY FEET IN
 CLEAR WIDTH. BATTERY BACK-UP FEATURE
 SHALL BE PROVIDED FOR GATE-ARMS SHOULD
 LOSS OF POWER OCCUR. TRAFFIC CALMING
 HUMPS ARE NOT TO INTERFERE WITH FIRE
 RESCUE MOVEMENT INTO THE COMPLEX.
 3) BUILDING LETTERS A,B,C, AND D, ARE TO
 BE PLACED ON THE BUILDING SINCE IT
 APPEARS TO BE A SINGLE ADDRESS FOR THE
 APARTMENT COMPLEX.
 4) AT LEAST ONE STAIR IS TO BE PROVIDED
 DURING CONSTRUCTION. TEMPORARY
 STANDPIPES ARE REQUIRED IN ALL BUILDINGS
 UNDER CONSTRUCTION WHEN THEY ARE
 REQUIRED TO HAVE STANDPIPE SYSTEMS.
 5) HOW IS THE COMBUSTIBLE LINT REMOVED
 FROM THE DRYER CHASE. NO ACCESS PANELS
 HAVE BEEN PROVIDED.
 6) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE INSTALLATIONS OF THE FIRE
 SPRINKLER SYSTEMS. NO HYDRAULIC
 CALCULATIONS PROVIDED WITH FIRE
 SPRINKLER DRAWINGS. STANDPIPE SYSTEMS
 REQUIRED IN ALL BUILDINGS THREE STORIES
 AND MORE THAN FIFTY FEET IN HEIGHT.
 ALL VERTICAL SHAFTS ARE TO BE FIRE
 SPRINKLER PROTECTED. PLEASE EXPLAIN
 RATIONALE FOR THE SINGLE FIRE
 DEPARTMENT CONNECTION SHOWN ON THE
 DRAWINGS.
 7) DOOR SWINGS IN THE STAIRWELLS ARE TO
 SWING IN THE DIRECTION OF EXIT TRAVEL.
 8) SMOKE DETECTORS WHEN INSTALLED ARE
 TO BE A MINIMUM OF THREE FEET FROM
 AIR CONDITIONER DIFFUSERS.
 9) TRASH CHUTES TO COMPLY WITH NFPA 82,
 STANDARD ON INCINERATORS, WASTE AND
 LINEN HANDLING SYSTEMS AND EQUIPMENT.
 10) PLEASE INDICATE PORTABLE FIRE
 EXTINGUIHSER LOCATIONS.
 11) SIGNS ARE REQUIRED FOR ALL BUILDINGS
 FOUR OR MORE STORIES. SIGNS SHALL
 INDICATE FLOOR LEVEL, THE IDENTITY OF
 THE STAIR, THE TERMINUS OF THE STAIR,
 TOP AND BOTTOM.
 12) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE FIRE ALARM SYSTEM.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2002-04-23 Cont ID  
Sent By pkrauss Date 2002-04-23 Time 08:46 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-04-23 00:00:00MECH PERMIT 01071102 PLAN UNDER PERMIT
 01040479

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2002-04-15 Cont ID  
Sent By pkrauss Date 2002-04-15 Time 12:14 Rev Time 0.50
Received By pkrauss Date 2002-04-15 Time 12:14 Sent To  
Notes
2002-04-15 00:00:00PROVISO:MECH PERMIT 01071102
  
 2 COPIES OF ORIGINAL LETTER FOR MONTHLY
 MAINTENANCE FOR THE CLEANING OF THE
 BOOSTER FAN.TWO NOTARIZED LETTERS TO
 FOLLOW.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 09:55 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-03-12 00:00:00SUBMITTAL-LOUVERS FOR THE ELEVATOR SHAFT

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 08:57 Rev Time 1.00
Received By pkrauss Date 2002-03-12 Time 08:57 Sent To  
Notes
2002-03-12 00:00:00*******************DENIED***************
  
 MECHANICAL PERMIT 01071102
 CALCULATIONS FOR DRYER EXHAUST
  
 PROVIDE SPECIFIC MANUFACTURER SUBMITTAL
 DATA & PURCHASE ORDER FOR DRYERS.
 DRYERS TO BE INSTALLED AT THE TIME OF
 FINAL INSPECTION.DUCTWORK TO BE
 INSTALLED AS PER SPECIFIC MANUFACTURERS
 INSTRUCTIONS. RESIDENTIAL DRYER EXHAUST
 DUCTS WHICH ARE NOT DESIGNED FOR A
 SPECIFIC DRYER SHALL COMPLY WITH 1997
 SMC 509.3
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-02-08 Cont ID  
Sent By pkrauss Date 2002-02-08 Time 09:28 Rev Time 0.35
Received By pkrauss Date 2002-02-08 Time 09:28 Sent To  
Notes
2002-02-08 00:00:00 
 MECH PERMIT 01071102
  
 LETTER FROM ENGINEER ON BATHROOM EXHAUST
 CALCULATIONS APPROVED.
  
 PLANS SUBMITTED ARE DENIED.DRYER
 EXHAUST TERMINATING AT A RATED WALL
 WHICH IS AN EGRESS CORRIDOR.FIRE
 DAMPERS ARE NOT PERMITTED IN DRYER
 EXHAUST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-05-24 Cont ID  
Sent By pkrauss Date 2001-05-24 Time 07:48 Rev Time 0.20
Received By pkrauss Date 2001-05-24 Time 07:47 Sent To  
Notes
2001-05-24 00:00:00NOTES UNDER PERMIT 01040480.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-24 Cont ID  
Sent By pkrauss Date 2001-05-24 Time 07:47 Rev Time 1.30
Received By pkrauss Date 2001-05-24 Time 07:47 Sent To  
Notes
2001-05-24 00:00:00NOTES UNDER PERMIT 01040480

Review Stop P PLUMBING
Rev No 10 Status P Date 2003-01-22 Cont ID  
Sent By kstevens Date 2003-01-22 Time 08:48 Rev Time 0.10
Received By kstevens Date 2003-01-22 Time 08:48 Sent To  
Notes
2003-01-22 00:00:00SUBMITTAL - PUMP SKID.

Review Stop P PLUMBING
Rev No 9 Status P Date 2002-09-26 Cont ID  
Sent By kstevens Date 2002-09-26 Time 10:45 Rev Time 0.00
Received By kstevens Date 2002-09-26 Time 10:45 Sent To  
Notes
2002-09-26 00:00:00REVISION OK - 2 6" SCUPPER LINES

Review Stop P PLUMBING
Rev No 8 Status P Date 2002-04-10 Cont ID  
Sent By kstevens Date 2002-04-10 Time 19:50 Rev Time 0.00
Received By kstevens Date 2002-04-10 Time 19:50 Sent To  
Notes
2002-04-10 00:00:00SUBMITTAL OK - DOMESTIC PUMP CHANGE

Review Stop P PLUMBING
Rev No 7 Status P Date 2002-02-28 Cont ID  
Sent By kstevens Date 2002-02-28 Time 14:09 Rev Time 0.50
Received By kstevens Date 2002-02-28 Time 14:09 Sent To  
Notes
2002-02-28 00:00:00SUBMITTAL FOR PUMP SYSTEM OK

Review Stop P PLUMBING
Rev No 6 Status P Date 2001-11-29 Cont ID  
Sent By kstevens Date 2001-11-29 Time 15:35 Rev Time 0.50
Received By kstevens Date 2001-11-29 Time 15:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2001-10-19 Cont ID  
Sent By kstevens Date 2001-10-19 Time 16:22 Rev Time 0.33
Received By kstevens Date 2001-10-19 Time 16:21 Sent To  
Notes
2001-10-19 00:00:00DENIED
  
 SEE COMMENTS FROM PERMIT #01040479
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 4 Status F Date 2001-09-28 Cont ID  
Sent By kstevens Date 2001-09-28 Time 15:05 Rev Time 0.33
Received By kstevens Date 2001-09-28 Time 15:05 Sent To  
Notes
2001-09-28 00:00:00DENIED
  
 1) SEE COMMENTS FROM #01040479
  
 2) RELIEF (T&P) LINE AND PAN DRAIN LINES
 TO BE 1-1/4" THRU SECOND FLOOR SGC-97,
 TABLE 305.3.3 AND COUNTYWIDE AMENDMENTS
 TO SPC-94 SEC 507.6.1.
  
 REFERENCES: SPC-94 - FACBC-97 - SGC-97
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-09-22 Cont ID  
Sent By pschmitz Date 2001-09-22 Time 09:32 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-09-22 00:00:00REVISION PLUMBING FOUNDATION ONLY. PES

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-17 Cont ID  
Sent By kstevens Date 2001-05-16 Time 16:18 Rev Time 1.00
Received By kstevens Date 2001-05-17 Time 09:44 Sent To  
Notes
2001-05-16 00:00:00REVIEW NOTES. PASSED ...PROVISO...
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO BE FILED WITH THE DEPARTMENT
 OF CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH.
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IS TWO FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIR CHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3, ACCESSABLE AND RE-
 CHARGABLE.
  
 4) T & P DISCHARGE LINE TO BE 1-1/4"
 THRU 2ND FLOOR PER SGC-97 TABLE 305.3.3
 AND COUNTYWIDE AMENDMENTS TO SPC-94
 507.6.1. ALSO PAN DRAIN LINE TO BE 1-1/4
 INCH THRU 2ND FLOOR FOR SAME REASON.
  
 5) PAGE P-4, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISER, BUT P/T #2 ONLY SHOWS
 SINGLE RISER. TWO RISERS ARE REQUIRED.
  
 6) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRE THAT SPEC. A OR B
 BE SHOWN ON PLAN.
  
 7) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND. 98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-04 Cont ID  
Sent By kstevens Date 2001-05-04 Time 14:10 Rev Time 5.00
Received By kstevens Date 2001-05-04 Time 14:09 Sent To  
Notes
2001-05-04 00:00:00REVIEW NOTES. FAILED
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO BE FILED WITH THE DEPARTMENT
 OF CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH.
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IN 2 FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIR CHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3 ACCESSABLE AND
 RECHARGEABLE.
  
 4) T & P DISCHARGE LINE TO BE 1-1/4"
 THRU 2ND FLOOR PER SGC-97 TABLE 305.3.3
 AND COUNTYWIDE AMENDMENTS SO SPC-94
 507.6.1. ALSO PAN DRAIN LINE TO BE
 1-1/4" THRU 2ND FLOOR FOR SAME REASON.
  
 5) PAGE P-4, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISERS, BUT P/T #2 ONLY SHOWS
 SINGLE RISER?
  
 6) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRES THAT SPEC. A OR
 B BE SHOWN ON PLAN.
  
 7) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND. 98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2001-08-23 Cont ID  
Sent By jwitmer Date 2001-08-23 Time 16:58 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-22 Cont ID  
Sent By sgraham Date 2001-05-22 Time 14:59 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-05-22 00:00:00APPROVED BY ANGELLA VANN


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved