Plan Review Details - Permit 01040480
Plan Review Stops For Permit 01040480
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2001-10-29 Cont ID  
Sent By jwitmer Date 2001-10-29 Time 10:23 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2001-10-01 Cont ID  
Sent By jwitmer Date 2001-10-01 Time 12:55 Rev Time 2.00
Received By jwitmer Date 2001-10-01 Time 12:55 Sent To  
Notes
2001-10-01 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01040480
 BLDG "B"
 609 EXECUTIVE CENTER DR
  
  
 SEE 01040479 SAME COMMENTS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-08-23 Cont ID  
Sent By jwitmer Date 2001-08-23 Time 16:59 Rev Time 1.00
Received By jwitmer Date 2001-08-23 Time 16:59 Sent To  
Notes
2001-08-23 00:00:00STRUCTURAL REVISIONS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-20 Cont ID  
Sent By jwitmer Date 2001-05-18 Time 11:18 Rev Time 2.00
Received By sjohnson Date   Time   Sent To  
Notes
2001-07-20 00:00:00APPROVED PER JIM WITMER
2001-05-18 00:00:00BUILDING PLAN REVIEW
 PLAN CHECK 01040480
 609 EXECUTIVE CENTER DR
 BUILDING "B" (5 STORY)
  
 SEE PLAN REVIEW 01040479

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-05-07 Cont ID  
Sent By jwitmer Date 2001-05-07 Time 17:16 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-05-07 00:00:00BUILDING PLAN REVIEW
 PLAN CHECK 01040480
 609 EXECUTIVE CENTER DRIVE
 BUILDING: B (5 STORY)
  
 1)- SHEET A.6 DETAIL 2 DEPICTS THE ROOF-
 ING TO BE ATTACHED TO PURLINS, AMENDMENT
 1503.1.2.2. REQUIRES ALLROOFING TO BE AP
 PLIED TO SOLID OR CLOSELY FITTED DECKING
 OR SHEATHING.
  
 2)- SOILS REPORT REQUIRED AMENMENTS
 1804.2.7.2.
  
 3)- COMPONENTS & CLADDING THERE IS NO
 WINDOW BUCK ATTACHMENT.
  
 4)- SHEET 2.3 DETAILS FOR THE REFUSE
 SHUTE ARE MISSING, A (2 HR) WALL WILL BE
 REQUIRED TO PROTECT THE SHUTE,
 SBC 705.2.4.2/ 705.2.4.3.
  
 5)- PRODUCT APPROVALS FOR ALL GLAZED
 OPENINGS CAN BE SUBMITTED AFTER THE PER-
 MIT IS ISSUED, A "PROVISO". THE CITY'S
 POLICY FOR GLAZED OPENINGS WILL BE
 ENFORCED!SBC 1606.4/1707.4.1.
  
 6)- ROOFING CAN ALSO BE ISSUED UNDER SEP
 ERATE PERMIT PRODUCT APPROVAL WILL BE RE
 QUIRED.
  
 7)- FL. SATUTE 553.895 REQUIRES FIRE
 SPRINKLER PLANS.
  
 8)- SHEET A.6 DEPICTS THE ROOFING WITH
 WIRE LATH THE BACKING OR SHEATHING
 DOESN'T DESCRIBE THE MATERIAL.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-29 Cont ID  
Sent By dpalmer Date 2001-10-29 Time 17:51 Rev Time 0.00
Received By dpalmer Date 2001-10-29 Time 17:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-20 Cont ID  
Sent By sjohnson Date 2001-07-20 Time 13:17 Rev Time 0.00
Received By sjohnson Date   Time   Sent To  
Notes
2001-07-20 00:00:00APPROVED PER D V PALMER
 APPROVED PER D V PALMER

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-05-24 Cont ID  
Sent By mamini Date 2001-05-24 Time 08:24 Rev Time 1.00
Received By mamini Date 2001-05-24 Time 08:24 Sent To  
Notes
2001-05-24 00:00:00PASSED :
 1. SEE PERMIT NUMBER 01030517 FOR REVIEW
 COMMENTS.
 IF ANY QUESTION PLEASE CONTACT 561-659-
 8096 EXT. 8096

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-05-23 Cont ID  
Sent By mcarsill Date 2001-05-23 Time 16:25 Rev Time 0.00
Received By mcarsill Date 2001-05-23 Time 16:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-05-18 Cont ID  
Sent By mcarsill Date 2001-05-18 Time 13:19 Rev Time 0.00
Received By mcarsill Date 2001-05-18 Time 13:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-05-03 Cont ID  
Sent By mcarsill Date 2001-05-03 Time 11:10 Rev Time 0.00
Received By mcarsill Date 2001-05-03 Time 11:10 Sent To  
Notes
2001-05-03 00:00:001) ALL UNDERGOUND FIRE MAINS ARE TO BE
 LISTED FOR FIRE PROTECTION SERVICE AND
 COMPLY WITH NFPA 24, FIRE SERVICE MAINS
 AND THEIR APPURTENANCES.
 2) INGRESS AND EGRESS INTO THE COMPLEX
 SHALL BE A MINIMUM OF TWENTY FEET IN
 CLEAR WIDTH. BATTERY BACK-UP FEATURE
 SHALL BE PROVIDED FOR GATE-ARMS SHOULD
 LOSS OF POWER OCCURS. TRAFFIC CALMING
 HUMPS ARE NOT TO INTERFERE WITH FIRE
 RESCUE MOVEMENT INTO THE COMPLEX.
 3) BUILDING LETTERS A,B,C, AND D, ARE TO
 BE PLACED ON THE BUILDING SINCE IT
 APPEARS TO BE A SINGLE ADDRESS FOR THE
 APARTMENT COMPLEX.
 4) AT LEAST ONE STAIR IS TO BE PROVIDED
 DURING CONSTRUCTION. TEMPORARY
 STANDPIPES ARE REQUIRED IN ALL BUILDINGS
 UNDER CONSTRUCTION WHEN THEY ARE
 REQUIRED TO HAVE STANDPIPE SYSTEMS.
 5) HOW IS COMBUSTIBLE LINT REMOVED
 FROM THE DRYER CHASE. NO ACCESS PANELS
 HAVE BEEN PROVIDED.
 6) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE INSTALLATIONS OF THE FIRE
 SPRINKLER SYSTEMS. NO HYDRAULIC
 CALCULATIONS PROVIDED WITH FIRE
 SPRINKLER DRAWINGS. STANDPIPE SYSTEMS
 ARE REQUIRED IN ALL BUILDINGS THREE
 STORIES AND MORE THAN 50 FIFTY FEET
 IN HEIGHT. ALL VERTICAL SHAFTS ARE TO
 BE FIRE SPRINKLER PROTECTED. PLEASE
 EXPLAIN RATIONALE FOR THE SINGLE
 FIRE DEPARTMENT CONNECTION SHOWN ON
 THE DRAWINGS.
 7) DOOR SWINGS IN THE STAIRWELLS ARE TO
 SWING IN THE DIRECTION OF EXIT TRAVEL.
 8) SMOKE DETECTORS WHEN INSTALLED ARE TO
 BE A MINIMUM OF THREE FEET FROM AIR
 CONDITIONER DIFFUSERS.
 9) TRASH CHUTES TO COMPLY WITH NFPA 82,
 THE STANDARD ON INCINERATORS, WASTE AND
 LINEN HANDLING SYSTEMS AND EQUIPMENT.
 10) PLEASE INDICATE PORTABLE FIRE
 EXTINGUISHER LOCATIONS.
 11) SIGNS ARE REQUIRED FOR ALL BUILDINGS
 FOUR OR MORE STORIES. SIGNS SHALL
 INDICATE FLOOR LEVEL, THE IDENTITY OF
 THE STAIR, THE TERMINUS OF THE STAIR,
 TOP AND BOTTOM.
 12) PLEASE INDICATE THE DISTANCES
 BETWEEN THE TRANSFORMER PADS AND THE
 EXITWAYS FROM THE BUILDING.
 13) PROVIDE SEPARATE PLANS AND PERMITS
 FOR THE FIRE ALARM SYSTEMS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2002-04-23 Cont ID  
Sent By pkrauss Date 2002-04-23 Time 08:44 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-04-23 00:00:00MECH PERMIT 01071097 - DUCT REVISION
 PLAN UNDER PERMIT01040479

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2002-04-15 Cont ID  
Sent By pkrauss Date 2002-04-15 Time 12:12 Rev Time 0.50
Received By pkrauss Date   Time   Sent To  
Notes
2002-04-15 00:00:00PROVISO:MECH PERMIT 01071097
  
 2 COPIES OF ORIGINAL LETTER FOR MONTHLY
 MAINTENANCE FOR THE CLEANING OF THE
 BOOSTER FAN.TWO NOTARIZED LETTERS TO
 FOLLOW.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2002-03-12 Cont ID  
Sent By pkrauss Date 2002-03-12 Time 09:54 Rev Time 0.30
Received By pkrauss Date   Time   Sent To  
Notes
2002-03-12 00:00:00SUBMITTAL FOR LOUVERS FOR THE ELEVATOR
 SHAFT.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2002-03-11 Cont ID  
Sent By pkrauss Date 2002-03-11 Time 14:53 Rev Time 1.00
Received By pkrauss Date 2002-03-11 Time 14:37 Sent To  
Notes
2002-03-11 00:00:00********************DENIED**************
  
 MECHANICAL PERMIT 01071097
 CALCULATIONS FOR DRYER EXHAUST -
  
 PROVIDE SPECIFIC MANUFACTURER SUBMITTAL
 DATA & PURCHASE ORDER FOR DRYERS.
 DRYERS TO BE INSTALLED AT THE TIME OF
 FINAL INSPECTION.DUCTWORK TO BE
 INSTALLED AS PER SPECIFIC MANUFACTURERS
 INSTRUCTIONS. RESIDENTIAL DRYER EXHAUST
 DUCTS WHICH ARE NOT DESIGNED FOR A
 SPECIFIC DRYER SHALL COMPLY WITH 1997
 SMC 509.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2002-02-13 Cont ID  
Sent By pkrauss Date 2002-02-13 Time 16:22 Rev Time 0.35
Received By pkrauss Date 2002-02-08 Time 09:01 Sent To  
Notes
2002-02-08 00:00:00 
 MECHANICAL PERMIT 01071097
  
 LETTER FROM ENGINEER ON BATHROOM
 EXHAUSTCALCULATIONS - APPROVED.
  
 PLANS SUBMITTED ARE DENIED.DRYER
 EXHAUST TERMINATING AT A RATE WALL
 WHICH IS AN EGRESS CORRIDOR.FIRE
 DAMPERS ARE NOT PERMITTED IN DRYER
 EXHAUST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-05-22 Cont ID  
Sent By pkrauss Date 2001-05-22 Time 15:48 Rev Time 1.30
Received By pkrauss Date 2001-05-22 Time 15:48 Sent To  
Notes
2001-05-22 00:00:00******************PROVISO***************
  
  
 PLEASE PROVIDE DETAIL FOR THE ELEVATOR
 SHAFT IS INCLUDED.(VENTILATION/FIRE
 PROTECTION 1997 SBC 3003.6)
  
 APARTMENTS CONSTRUCTED TO COMPLY WITH
 THE FAIR HOUSING ACT SHALL MEET THE
 HEIGHT REQUIREMENT FOR THERMOSATS AS
 PER SECTION 5.5 OF THE FAIR HOUSING ACT
 DESIGN MANUAL.
  
 CLUBHOUSE:SHOULD WALLS BETWEEN "CARD
 ROOM" AND "UTILITY ROOM"BE RATED,
 FIRE DAMPERS WILL BE REQUIRED AS PER
 1997 SMC 610.1.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-05-17 Cont ID  
Sent By pkrauss Date 2001-05-17 Time 12:20 Rev Time 0.45
Received By pkrauss Date 2001-05-17 Time 11:59 Sent To  
Notes
2001-05-17 00:00:00COMMENTS FROM FRIST REVIEW STAND...HAVE
 NOT CHANGED ANY MECHANICAL PLANS.SPOKE
 WITH SEAN REVISIONS TO COME LATER.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-10 Cont ID  
Sent By pkrauss Date 2001-05-10 Time 09:23 Rev Time 0.00
Received By pkrauss Date 2001-05-10 Time 08:35 Sent To  
Notes
2001-05-10 00:00:00PERMIT 01040480 - 609 EXEC. CTR. DR.
 PERMIT 5 STORY, PLAN REFLECT 3 STORY
  
  
 1.DRYER SUBDUCT NEEDS TO INDICATE
 ACCESS FOR CLEANOUT.
  
 2.DRYER SUBDUCT NEEDS TO INDICATE
 MEANS OF FIRE PROTECTION AS PER
 NFPA 13 4-4.8.
  
 3.GALV. STL. SUBDUCT FOR DYER VENT
 & TOILET EXHAUST - IS INSIDE OF
 SUBDUCT GALVENIZED?
  
 4.DRAWING A6.0 DEPICTS AHU AND WATER
 HEATER CLOSET,AHU MUST HAVE CLEAR
 ACCESS FOR REPLACEMENT OF AHU &
 FOR CONECTION OF DUCT TO UNIT AS
 WELL AS FOR INSPECTION.
  
 5.CONDENSATE TO DRYWELL OKAY, WHAT
 ABOUT OVERFLOW PROTECTION FOR
 AUXILIARY DRAIN PAN AS PER 1997
 SMC 304.8.6.1.(DWG P-2)
  
 6.PLEASE SUBMIT DETAIL OF CONDENSER
 UNIT STANDS,MINIMUM OF 18" FROM
 ROOF SURFACE TO BOTTOM OF SUPPORT
 RAIL (AMENDED 1997 SMC 304.2.5)
 DETAIL MUST BE AN ENGINEERED
 DRAWING.(UPLIFT/WINDLOAD AND
 HOW TO ATTACH TO ROOF STRUCTURE.)
  
 7.NO DETAIL FOR THE ELEVATOR SHAFT
 IS INCLUDED.(VENTILATION/FIRE
 PROTECTION 1997 SBC 3003.6)

Review Stop P PLUMBING
Rev No 10 Status P Date 2003-01-22 Cont ID  
Sent By kstevens Date 2003-01-22 Time 08:46 Rev Time 0.10
Received By kstevens Date 2003-01-22 Time 08:46 Sent To  
Notes
2003-01-22 00:00:00SUBMITTALS - PUMP SKID

Review Stop P PLUMBING
Rev No 9 Status P Date 2002-09-26 Cont ID  
Sent By kstevens Date 2002-09-26 Time 10:59 Rev Time 0.00
Received By kstevens Date 2002-09-26 Time 10:59 Sent To  
Notes
2002-09-26 00:00:00REVISION OK - ADDING 2 6" SCUPPER LINES

Review Stop P PLUMBING
Rev No 8 Status P Date 2002-04-10 Cont ID  
Sent By kstevens Date 2002-04-10 Time 19:47 Rev Time 0.00
Received By kstevens Date 2002-04-10 Time 19:47 Sent To  
Notes
2002-04-10 00:00:00SUBMITTAL OK - NEW DOMESTIC PUMPS

Review Stop P PLUMBING
Rev No 7 Status P Date 2002-03-01 Cont ID  
Sent By kstevens Date 2002-03-01 Time 14:32 Rev Time 0.50
Received By kstevens Date 2002-03-01 Time 14:32 Sent To  
Notes
2002-03-01 00:00:00RESUBMITTAL OF SUBMITTAL FOR PUMP ROOM
 REVISED MANIFOLD CONFIGURATION TO FIT RM

Review Stop P PLUMBING
Rev No 6 Status P Date 2002-02-28 Cont ID  
Sent By kstevens Date 2002-02-28 Time 14:05 Rev Time 0.50
Received By kstevens Date 2002-02-28 Time 14:05 Sent To  
Notes
2002-02-28 00:00:00SUBMITTALS FOR BOOSTER PUMB 0K

Review Stop P PLUMBING
Rev No 5 Status P Date 2001-11-29 Cont ID  
Sent By kstevens Date 2001-11-29 Time 15:51 Rev Time 0.50
Received By kstevens Date 2001-11-29 Time 15:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2001-10-19 Cont ID  
Sent By kstevens Date 2001-10-19 Time 16:20 Rev Time 0.33
Received By kstevens Date 2001-10-19 Time 16:20 Sent To  
Notes
2001-10-19 00:00:00DENIED
 SEE COMMENTS FROM PERMIT #1040479
  
 REVIEW BY KEN STEVENS
 (561) 659-8096

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-09-28 Cont ID  
Sent By kstevens Date 2001-09-28 Time 15:00 Rev Time 0.33
Received By kstevens Date 2001-09-28 Time 15:00 Sent To  
Notes
2001-09-28 00:00:00DENIED
  
 SEE COMMENTS FROM PERMIT #01040479
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-22 Cont ID  
Sent By pschmitz Date 2001-09-22 Time 10:08 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-09-22 00:00:00REVISION,PLUMBING FOUNDATION ONLY. PES

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-05-17 Cont ID  
Sent By kstevens Date 2001-05-16 Time 18:57 Rev Time 1.50
Received By pschmitz Date 2001-05-17 Time 08:43 Sent To  
Notes
2001-05-16 00:00:00REVIEW NOTES. PASSED...PROVISO...
  
 1) GENERAL NOTES #15 COPIES OF ALL DOC-
 UMENTS TO BE FILED WITH THE DEPARTMENT
 OF CONSTRUCTION SERVICES. CHANGE "L" TO
 CITY OF WEST PALM BEACH. GNI 1 OF 1.
  
 2) TYPICAL WATER RISER DIAGRAM - MAXIMUM
 FIXTURES ON 1/2" COLD IS 2 FIXTURES.
 MODEL COUNTYWIDE AMENDMENTS TO SPC-94
 607.7
  
 3) AIR CHAMBERS TO COMPLY WITH SPC-94
 607.8.2 & 607.8.3
  
 4) PAGE P-4, P/T #1 ON FLOOR PLAN SHOWS
 2 SEPARATE RISERS, BUT P/T #2 ONLY SHOWS
 A SINGLE RISER. TWO RISERS ARE REQUIRED.
  
 5) FAIR HOUSING ACT 1996 AMENDED 1998
 REQUIREMENT 7B REQUIRES THAT SPEC. A OR
 B BE SHOWN ON PLAN.
  
 6) PAGE A8.1 BACKING AT TUB TO BE 1'-5"
 NOT 1'-2" AS SHOWN ON PLAN. FHA-96
 AMEND. - 98 REQUIREMENT 6.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-20 Cont ID  
Sent By sgraham Date 2001-05-04 Time 14:05 Rev Time 0.00
Received By sjohnson Date   Time   Sent To  
Notes
2001-05-04 00:00:00NEED MINOR AMENDMENT