| Plan Review Stops For Permit 01040196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-05-07 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-13 |
Time |
16:14 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01040196 | | | 560 VILLAGE BLVD/ 250 | | | QUEST CONTRACTING | | | 691-9400 | | | | | | 1)- 1997 FL ACCESSIBILITY CODE 4.1.6.2.2 | | | ALTERATION TO AN AREA CONTAINING A | | | PRIMARY FUNCTION: DISPROPORTIONATE COST | | | IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO | | | PROVIDE, PRIORITY SHOULD BE GIVEN TO | | | THOSE ELEMENTS THAT WILL PROVIDE THE | | | GREATEST ACCESS, IN THE FOLLOWING ORDER: | | | A)ACCESSIBLE ENTRY | | | B)ACCESSIBLE ROUTE / ALTERED AREAS | | | C)AT LEAST ONE ACCESSIBLE FOR EACH SEX | | | OR A UNISEX RESTROOM. NEITHER RESTROOM | | | 1 OR 2 MEETS THE ACCESSIBILITY CODE. | | | | | | 2)- SBC 903.1 AN APPROVED FIRE SPRINKLER | | | LAY OUT( SHOP DRAWINGS) REQUIRED. | | | | | | 3)- SBC TABLE 1004 REQUIRES A MINIMUM OF | | | 44" FOR CORRIDOR & ISLE WIDTH. | | | | | | 4)- SBC 803.3 MISSING IS INFORMATION ON | | | TABLE 803.3 FOR THE MINIMUM INTERIOR | | | FINISH CLASSIFICATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-07 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-07 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-16 |
Time |
22:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-16 |
Time |
22:20 |
Sent To |
|
|
| Notes |
| 2001-04-16 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT TWO DIFFERENT | | | SETS OF ELEC DRAWING WERE SUBMITTED AND | | | ONE SET INCLUDED E-1,2,3 AND THE OTHER | | | TWO SETS CONTAINED E-2,3? PLEASE | | | SUBMIT FOR PROPER REVIEW. | | | | | | 2)NOTE: PLEASE NOTE THAT IF PLANS | | | SUBMITTED INCLUDENEW PANEL, THEN | | | PLEASE SUBMIT LOAD CALCULATIONS PER | | | 215-5 FOR | | | ADDED LOAD TO EXISTING HV PANEL. ECT | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-04-16 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-04-16 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-04-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-30 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-30 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-04-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-05 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-05 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2001-04-05 00:00:00 | 1) FIRE DAMPERS NOT SHOWN WHERE AIR | | | CONDITIONING PASSES THROUGH TENANT | | | SEPARATION WALL. | | | 2) PROVIDE PERMIT AND SHOP DRAWINGS | | | FOR FIRE SPRINKLER REMODEL. | | | 3) MINIMUM WIDTH OF CORRIDORS AND | | | PASSAGEWAYS SHALL BE AT LEAST 44 INCHES | | | WIDE. | | | 4) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION INFORMATION. | | | 5) PLEASE INDICATE EMERGENCY LIGHT | | | FIXTURE LOCATIONS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-05-09 |
Time |
09:38 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-05-09 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2001-05-09 00:00:00 | NOTES ON MECH PERMIT 01040205 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-17 |
Time |
12:21 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-04-17 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2001-04-17 00:00:00 | ******************DENIED**************** | | | | | | ALL EXISTING FIRE DAMPERS MUST BE | | | INDICATED ON THE PLAN. | | | | | | PLEASE PROVIDE INFORMATION ON EXHAUST | | | FAN TO BE INSTALLED. | | | | | | NO COMBUSTIBLES ABOVE THE CEILING IN THE | | | RETURN AIR PLENUM, 1997 SMC 609.1.1. | | | | | | | | | NOTE:PRIOR TO CONNECTING TO ANY | | | EXISTING DUCTWORK, CALL FOR | | | AN INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-05-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-05-14 |
Time |
09:33 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-05-14 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-05-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-05-06 |
Time |
14:37 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-06 00:00:00 | PLUMBING PLAN REVIEWDENIED | | | (1) WASH ROOM #1 TOCOMPLY WITH FACBC | | | SEC4.1.3(11) EACH PUBLIC AND COMMON USE | | | TOILET RM,SHALL COMPLY WITH 4.22 | | | ACCESSIBLE TOILET TO BE ON AN ACCESIBLE | | | ROUTE, CLEAR FLR SPACE,GRAB BARS. | | | (2) IF CONFERENCE RM SINK, IS A BREAK | | | RM SINK,THEN IT TOO WILL HAVE TO | | | COMPLY WITH FACBC 4.24.2 SINK HEIGHT | | | 34" FF,WITH KNEE CLEARANCE 4.23.3 | | | END OF COMMENTPAUL SCHMITZ | | | QUESTIONS561-659-8096 X 8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-04-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-04-18 |
Time |
18:06 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2001-04-18 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2001-04-18 00:00:00 | PLUMBING PLAN REVIEW. | | | DENIED: | | | NOT ENOUGH INFORMATION. | | | RISER DIAGRAMS FOR SANITARY | | | AND WATER ARE REQUIRED ECT: | | | | | | END OF COMMENTS. | | | | | | QUESTIONS CALL KEN STEVENS | | | (561) 659-8096 X'S 8389/8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-04-16 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-04-16 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|