Plan Review Details - Permit 01040106
Plan Review Stops For Permit 01040106
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-04-26 Cont ID  
Sent By jwitmer Date 2001-04-26 Time 13:04 Rev Time 0.70
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-05-08 Cont ID  
Sent By dpalmer Date 2001-05-08 Time 11:33 Rev Time 0.00
Received By dpalmer Date 2001-05-08 Time 11:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-01-16 Cont ID  
Sent By dpalmer Date 2001-04-16 Time 15:30 Rev Time 0.00
Received By dpalmer Date 2001-04-16 Time 15:30 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-05-09 Cont ID  
Sent By pkrauss Date 2001-05-09 Time 12:44 Rev Time 0.00
Received By pkrauss Date 2001-05-09 Time 12:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-04-05 Cont ID  
Sent By mcarsill Date 2001-04-05 Time 12:55 Rev Time 0.00
Received By mcarsill Date 2001-04-05 Time 12:55 Sent To  
Notes
2001-04-05 00:00:001) INTERIOR FINISH ON WALLS AND
 CEILING TO MEET MINIMUM FIRE CODE
 REQUIREMENTS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-05-09 Cont ID  
Sent By pkrauss Date 2001-05-09 Time 12:42 Rev Time 0.25
Received By pkrauss Date 2001-05-09 Time 12:38 Sent To  
Notes
2001-05-09 00:00:00RESUBMITTAL APPROVED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-04-13 Cont ID  
Sent By pkrauss Date 2001-04-13 Time 08:56 Rev Time 0.40
Received By pkrauss Date 2001-04-13 Time 07:42 Sent To  
Notes
2001-04-13 00:00:00 
  
 PLEASE PROVIDE INFORMATION ON WHERE GAS
 VENTS FROM THE BUILDING.
  
  
 NOTE - ADDITIONAL PERMIT REQUIRED
 FOR HOOD, SUBMIT PLANS WITH
 MECHANICAL PERMIT APPLICATION.
 (INCLUDE GREASE DUCT AND MAKE
 UP AIR AS WELL AS HOOD DETAILS)
  
 ADDITIONAL PERMIT REQUIRED FOR
 WALKIN COOLERS AND CONDENSERS,
 SUBMIT PLANS WITH MECHANICAL
 PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-05-06 Cont ID  
Sent By pschmitz Date 2001-05-06 Time 06:38 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-05-06 00:00:00PLUMBING PLAN REVIEWDENIED
 (1) DOOR SWING ON WOMENS REST RM,TO
 SWING OUT,SHOW THIS ON ALL REFERNCES.
 FACBC 4.23.2,4.22.2
 (2) SHOW LOCATION OF SHOCK ARRESTORS,
 AIR CHAMBERS DO NOT COMPLY WITH 607.8.3
 (3) SHT A-3 GREASE WASTE TO COMPLY WITH
 SPC 94 SEC 921.4,MAIN TRUNK LINE 4" ALL
 BRANCHES 3", VENTS ON EACH END.
 (4) NO SAFE WASTE,EACH PLBG FIXTURE TO
 BE INDIVUDALY TRAPED.SEC 1001.8.1
 (5)SHT A-3 GAS RISER,PLEASE COMPLY WITH
 GAS PERMIT APPLICATION REQUIRMENTS,SEE
 ATTACHED,ADDRESS NOTES 2,3,5,9.SEC 104.1
 (6) EMERGENCY SOV BELOW CEILING,MANUAL
 SOV TO BE UP STREAM OF EMERGENCY SOV,
 WITH A UNION DOWN STREAM OF EMERGENCY
 SOV. (SHUT OFF VALVE)
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS 561-659-8096 X 8233

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-04-17 Cont ID  
Sent By jleech Date 2001-04-17 Time 15:24 Rev Time 2.50
Received By pschmitz Date 2001-04-17 Time 15:24 Sent To  
Notes
2001-04-17 00:00:00DENIED;
  
 1.BATHROOM DOORS SWING INTO CLEAR FLOOR
 SPACE OF LAVITORYS.
  
 2.3 COMPARTMENT SINK TO DRAIN INDIRECTLY
 TO A FLOOR SINK. SPC 804.1
  
 3.GREASE TRAP SIZE AND LOCATION MUST BE
 APPROVED BY THE UTILITY DEPARTMENT.
 CALL RODNEY COMPO AT 837-4074.
  
 4.APPROVED ENGINEERED MECHANICAL WATER
 HAMMER ARRESTERS SHALL BE SIZED AND
 INSTALLED PER ENGINEER'S REQUIREMENTS.
 607.8.2 AND 607.8.3.
  
 5.FLOOR DRAINS IN RESTROOMS TO HAVE TRAP
 PRIMERS. 409.4.1.1.
  
 6.GAS RISER;
 A.TYPE OF GAS TO BE INSTALLED.
 B.DELIVERY PSI.
 C.APPROVED GAS CODE IS 97 SGC
 TABLE 305.1A
 D.ANSAL VALVE SHALL BE LOCATED NEXT
 TO HOOD BELOW THE CEILING.
 E.SHUTOFF VALVE SHALL BE INSTALLED
 UP STREAM OF THE EMERGENCY SHUT-
 OFF VALVE.
 F.UNDER SLAB GAS PIPING NOT
 PERMITTED. CHANMEL OUT CONCRETE
 FLOOR COAT GAS PIPE AND FILL
 FLOOR WITH LIGHT WEIGHT CONCRETE.
 G.SIZE ALL PIPE ON GAS RISER.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8377

Review Stop Z ZONING
Rev No 1 Status N Date 2001-05-09 Cont ID  
Sent By pkrauss Date 2001-05-09 Time 12:44 Rev Time 0.00
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy