|
 |
 |
 |
 |
 |
Plan Review Details - Permit 01040095
| Plan Review Stops For Permit 01040095 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-10-23 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-10-23 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2001-10-23 00:00:00 | ******************** UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE THAT PLANS WERE | | | SUBMITTED AND ARE FOR "FINAL" "CO". | | | PLEASE NOTE THAT THE CODE ART REFERENCED | | | FOR GROUNDING ELECTRODE CONDUCTORS, | | | ARE UNDER "96 NEC. ART FOR "99" NEC IS | | | 250-50. | | | COLD WATER PIPE ALSO,,,(IF METAL) | | | | | | 2)NOTE: PLEASE NOTE MISSING EQUIPMNET | | | GROUNDING CONDUCTOR BETWEEN MAIN AND | | | PANEL. PER 250-122 | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW | | | BEFORE FINAL.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-25 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-25 |
Time |
17:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-05-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-02 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-02 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2001-05-02 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING AND AFTER CONSTRUCTION. | | | 2) BUILDING ADDRESSES REQUIRED PER CITY | | | CODE REQUIREMENTS. | | | 3) ELECTRIC POWERED SMOKE DETECTORS ARE | | | REQUIRED. | | | 4) PORTABLE FIRE EXTINGUISHERS WITH | | | CURRENT SERVICE TAGS ARE REQUIRED. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-25 |
Time |
13:17 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2001-04-25 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2001-04-25 00:00:00 | MECH PERMIT 01040147 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-04-23 |
Time |
20:24 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2001-04-23 |
Time |
20:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2001-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-05-01 |
Time |
18:14 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-05-01 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2001-05-01 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-FLOOD ZONE AO. PROVIDE ELEVATION | | | CERTIFICATE. | | | | | | 2-PROVIDE PRODUCT APPROVAL FOR: | | | -DOUBLE FRENCH DOORS. | | | -FRENCH W/ SIDELITES SINGLE ASSEMBLY. | | | -WINDOW MULLIONS. | | | -UL LISTING AND SPECS FOR BBQ. | | | | | | 3-PROVIDE COMPLETE INFORMATION FOR | | | STORM PANELS UNDER A SEPARATE PERMIT. | | | | | | 4-PROVIDE ENGINEERED BORINGS AS | | | REQUESTED BY DUNKELBERGER ENGINEERING | | | ON THEIR PRELIMINARY SOIL TEST REPORT. | | | | | | 5-PROVIDE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE FORM | | | COMPLETED BY THE ENGINEER OF RECORD. | | | | | | | | | NOTE: | | | THESE COMMENTS APPLY TO THE FOLLOWING | | | PERMIT NUMBERS: 01040095, 01040100, | | | 01040105, 01040107, 01040108, 01040109. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-04-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-04-17 |
Time |
09:54 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |