Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-05-21 Cont ID  
Sent By dpalmer Date 2001-05-21 Time 16:18 Rev Time 0.00
Received By dpalmer Date 2001-05-21 Time 16:18 Sent To  
Notes
2001-05-21 00:00:00*************** REVISION NEEDED ******
  
 1)NOTE: PLEASE NOTE THAT PER F.A.C.
 471.025/481.221 AND PLANS THAT ARE
 SIGNED AND SEALED BY AN ARCH/ENG NEED
 TOHAVE ALL CHANGES ON PLANS DONE BY
 THATPERSON. PLEASE NOTE THAT THESE
 PLANSARE OK FOR INSPECTIONS UNTIL FINAL.
 PLEASE HAVE ALL CHANGES RE-PRINTED
 BEFORE FINAL BY THE ENGINEER OF RECORD.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE FINAL. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-04-18 Cont ID  
Sent By dpalmer Date 2001-04-18 Time 18:49 Rev Time 0.00
Received By dpalmer Date 2001-04-18 Time 18:48 Sent To  
Notes
2001-04-18 00:00:00************ REVISION REQ`UESTED *******
  
  
 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 OF EXISTING SERVICE AND ADDING OF NEW
 LOAD AT CABANNA.
  
 2)NOTE: PLEASE HAVE PLANS RE-DRAWN
 BEFORE FINAL ELECTRICAL INSPECTION BY
 ARCH/
 ENGINEER OF RECORD.
  
  
 PLEASE SUBMIT ABOVE BEFORE FINAL.
 IF THERE ARE ANY QUESTIONS. PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-04-04 Cont ID  
Sent By dpalmer Date 2001-04-04 Time 19:45 Rev Time 0.00
Received By dpalmer Date 2001-04-04 Time 19:45 Sent To  
Notes
2001-04-04 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NOT ENOUGH
 INFORMATION WAS SUBMITTED FOR REVIEW.
 PLEASE SUBMIT INFORMATION FOR WHERE
 ELECTRICAL IS COMING FROM??????
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 MISSING SD IN CABANNA.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372